LWYC series turbine flowmeter
Features: Liquid Form: Integrated/Plug in/Split Power Supply: DC24V or AC220V Output: Pulse Output or Current: 4-20mA Model: LWYC Series Temperature:
Product details

LWYC series turbine flowmeterbrief introduction

The LWYC series turbine flowmeter is a new generation of turbine flowmeter that has been optimized and designed based on advanced technology of flow meters at home and abroad. It has the characteristics of simple structure, lightweight, high accuracy, good reproducibility, sensitive response, and easy installation, maintenance, and use. It is widely used to measure liquids in closed pipelines that do not corrode stainless steel 1Cr18Ni9Ti, 2Cr13, corundum Al2O3, and hard alloys, and have no impurities such as fibers or particles. The liquid with a kinematic viscosity of less than 5 × 10-6m2/s at working temperature can be used after real liquid calibration of the flowmeter. If paired with display instruments with special functions, it can also perform quantitative control, over limit alarm, etc., making it an ideal instrument for flow measurement and energy conservation.

Product Features

  • High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;

  • Good repeatability, short-term repeatability can reach 0.05% to 0.2%. It is precisely because of its good repeatability that frequent calibration or online calibration can achieve extremely high accuracy, making it a preferred flowmeter for trade settlement;

  • Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;

  • High frequency signals (3-4 kHz) can be obtained, with strong signal resolution;

  • Range measurement, with a medium to large caliber of up to 1:20 and a small caliber of 1:10;

  • Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;

  • Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;

  • specializedsensorThere are many types, which can be designed as various specialized sensors according to the special needs of users, such as low-temperature, bidirectional, downhole, sand mixing, etc

  • Can be made into an insertion type, suitable for large-diameter measurement, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance

Basic parameters and technical performance

Instrument caliber and connection method

4. 6, 10, 15, 20, 25, 32, 40 are connected by threads

(15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges

accuracy class

± 1% R, ± 0.5% R, ± 0.2% R (to be customized)

Range ratio

1:10; 1:15; 1:20

Instrument material

304 stainless steel, 316 (L) stainless steel, etc

Temperature of the tested medium (℃)

-20~+120℃

environmental condition

Temperature -10~+55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106Kpa

output signal

Sensor: Pulse frequency signal, low level ≤ 0.8V, high level ≥ 8V

Transmitter: two-wire 4-20mADC current signal

power supply

Sensor:+12VDC,+24VDC (optional)

Transmitter:+24VDC

On site display type: The instrument comes with a 3.2V lithium battery

Signal transmission line

STVPV3 × 0.3 (three wire system), 2 × 0.3 (two wire system)

Distance

≤1000m

Signal line interface

Basic type: Hausman connector, explosion-proof type: internal thread M20 × 1.5

Explosion proof grade

Basic Type: Non Explosion proof Product, Explosion proof Type: ExdIIBT6

protection grade

IP65

Measurement range and work pressure

Instrument caliber

(mm)

Normal flow range

(m3/h)

Expand traffic range

(m3/h)

Default installation method and voltage rating

Optional installation methods and default voltage rating

Specially designed pressure resistance level

(MPa)

DN4

0.04~0.25

0.04~0.4

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

12. 16, 25

DN6

0.1~0.6

0.06~0.6

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

12. 16, 25

DN10

0.2~1.2

0.15~1.5

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

12. 16, 25

DN15

0.6~6

0.4~8

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

4.0, 6.3, 12, 16, 25

DN20

0.8~8

0.45~9

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

4.0, 6.3, 12, 16, 25

DN25

1~10

0.5~10

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

4.0, 6.3, 12, 16, 25

DN32

1.5~15

0.8~15

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

4.0, 6.3, 12, 16, 25

DN40

2~20

1~20

Threaded installation, 6.3Mpa

Flange installation, 2.5MPa

4.0, 6.3, 12, 16, 25

DN50

4~40

2~40

Flange installation, 2.5Mpa

Threaded connection, 6.3MPa

4.0, 6.3, 12, 16, 25

DN65

7~70

4~70

Flange installation, 1.6Mpa

Threaded connection, 6.3MPa

4.0, 6.3, 12, 16, 25

DN80

10~100

5~100

Flange installation, 1.6Mpa

Threaded connection, 6.3MPa

4.0, 6.3, 12, 16, 25

DN100

20~200

10~200

Flange installation, 1.6Mpa

4.0, 6.3, 12, 16, 25

DN125

25~250

13~250

Flange installation, 1.6Mpa

2.5, 4.0, 6.3, 12, 16

DN150

30~300

15~300

Flange installation, 1.6Mpa

2.5, 4.0, 6.3, 12, 16

DN200

80~800

40~800

Flange installation, 1.6Mpa

2.5, 4.0, 6.3, 12, 16

Flow meter selectionAnd specifications:

model

describe

LWGY








Basic type, powered by+5-24DCV, without on-site display

LWGB








4-20mA two-wire current output, without on-site display

LWY








Battery powered on-site display type

LWYC








On site display/4~20mA two-wire current output

state-owned

call

open up or clear out by poking or jabbing

footpath

4







4mm, The standard range is 0.04-0.25m3/h, and the wide range is 0.04-0.4m3/h

6

6mm, The standard range is 0.1-0.6m3/h, and the width measuring wheel is 0.06-0.6m3/h

10

10mm, The standard range is 0.2-1.2m3/h, and the wide range is 0.15-1.5m3/h

15

15mm, The standard range is 0.6-6m3/h, and the wide range is 0.4-8m3/h

20

20mm, The standard range is 0.8-8m3/h, and the wide range is 0.4-8m3/h

25

25mm, The standard range is 1-10m3/h, and the wide range is 0.5-10m3/h

32

32mm, The standard range is 1.5-15m3/h, and the wide range is 0.8-15m3/h

40

40mm, The standard range is 2-20m3/h, and the wide range is 1-20m3/h

50

50mm, The standard range is 4-40m3/h, and the wide range is 2-40m3/h

65

65mm, The standard range is 7-70m3/h, and the wide range is 4-70m3/h

80

80mm, The standard range is 10-100m3/h, and the wide range is 5-100m3/h

100

100mm, The standard range is 20-200m3/h, and the wide range is 10-200m3/h

125

125mm, The standard range is 25-250m3/h, and the wide range is 13-250m3/h

150

150mm, The standard range is 30-300m3/h, and the wide range is 15-300m3/h

200

200mm, The standard range is 80-800m3/h, and the wide range is 40-800m3/h

communication

C1

On site display/RS485 communication protocol

C2

On site display/ART communication protocol

accuracy class

05

Accuracy level 0.5

10

Accuracy level 1.0

turbine

type

W

Wide range turbine

S

Standard turbine

material

S

304 stainless steel

L

316 (L) stainless steel

P

Rubber and Plastic

explosion-proof


Unmarked, non explosion proof type

E

Explosion proof type (Exm Ⅱ CT6 or Exd Ⅱ BT6)

pressure rating

N

Conventional (refer to measurement range and working pressure gauge)

Note: DN15 to DN40 are usually threaded connections. If you want to use flange connections, please add "(FL)" after "nominal diameter". For example, if you choose a flange connected explosion-proof turbine flowmeter to measure diesel, the pipeline is DN40, and the current signal needs to be displayed and transmitted remotely on site, with an accuracy of 0.5 level, made of 304 stainless steel material, and the instrument pressure resistance is 16MPa. The measurement range is the standard range, and the product model should be:LWGC-4005S-SEN16

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!