Overview of LW vertical unobstructed sewage pump
The LW vertical non blocking sewage pump is developed by introducing advanced foreign technology and absorbing and transforming it. All performance indicators meet the national standard for similar products. Due to the use of unique single (double) channel impellers, it has strong drainage capacity and can effectively pass through 5 times the diameter of the pump and solid particles with a diameter of 50% of the pump diameter. The dynamic seal adopts two sets of special hard alloy mechanical seal devices made of cast iron and stainless steel. This series of pumps adopts a unique impeller structure and mechanical seal, which can effectively transport solids and long fibers. Compared with traditional impellers, the impeller of this pump adopts a single channel or double channel form, which is similar to a curved pipe with the same cross-sectional size and has very good flow characteristics. Coupled with a reasonable volute chamber, the pump has high efficiency and the impeller has undergone dynamic and static balance tests, making the pump operate without vibration. The hydraulic performance of this pump is advanced and mature. After testing, all performance indicators of the product have reached the relevant standards and regulations. After its launch on the market, the product has been welcomed and praised by a large number of users for its unique efficacy, reliable performance, and stable quality.
LW vertical non blocking sewage pump product features
1. By adopting a unique single blade or double blade impeller structure, the passage capacity of pollutants is greatly improved, which can effectively pass through 5 times the diameter of fiber material and solid particles with a diameter of about 50% of the pump diameter;
2. The mechanical seal is made of hard all metal corrosion-resistant tungsten carbide material, which allows it to operate in the oil chamber for a long time and can ensure safe and continuous operation of the pump for more than 8000 hours;
3. The overall structure is compact, the volume is small, the noise is low, the energy-saving effect is significant, and the maintenance is convenient. At the same time, due to the use of standard Y series motors, it is easy for users to replace them;
4. The automatic control cabinet can automatically control the pump's over movement and stop according to the required liquid level changes, without the need for dedicated personnel to supervise, making it extremely convenient to use;
5. Square or circular installation systems can be equipped according to user needs, which brings great convenience to installation and maintenance. People do not need to enter the sewage pit for this purpose;
6. Can be used within the full head range while ensuring that the motor does not overload;
7. If the sewage pump is equipped with an outdoor motor, there is no need to build a pump room, and it can be directly installed outdoors to save costs;
8. The pump is a vertical structure.
LW vertical non blocking sewage pump product usage
The LW series non blocking sewage pump is suitable for the discharge of severely polluted wastewater in factories and commercial areas, sewage discharge stations in main residential areas, water distribution systems in urban sewage treatment plants, drainage stations in civil air defense systems, water supply equipment in water plants, sewage discharge in hospitals and hotels, municipal engineering construction sites, mining supporting machines, rural biogas digesters, farmland irrigation and other industries. It can also be used for conveying granular sewage and pollutants, as well as for clean water and weakly corrosive media.
Usage conditions of LW vertical unobstructed sewage pump
1. The operating environment temperature of the sewage pump is ≤ 40 ℃, and the humidity is ≤ 95%; If the altitude is ≤ 1000 meters, it should be raised when ordering.
2. The medium temperature shall not exceed 60 ℃, and the medium density shall be 1-1.3kg/dm3.
3. The use range of cast iron material is PH5-9.
4. 1Cr18Ni9Ti stainless steel material can be used with general corrosive media.
5. The altitude of the usage environment should not exceed 1000 meters. If it exceeds, it should be mentioned when placing an order to provide you with more reliable products.
Note: If the user has special requirements for temperature, medium, etc., please specify the detailed information of the conveying medium when ordering, so that our unit can provide more reliable products.
Structural Description of LW Vertical Non blocking Sewage Pump
The LW vertical sewage pump is a single suction volute pump equipped with non clogging and anti winding single (double) large channel impellers, which have good passing capacity. This series of pumps has two structural forms, one is that the motor is directly coaxial with the pump, and the other is that it is connected by a coupling, and the motor adopts a standard vertical motor. The structural diagram is as follows, and each structural form has two types of base connection forms. One is the inlet horizontal suction, which has a corner function and can be placed at 0 °, 90 °, 180 °, 270 ° according to usage requirements for pipeline connection. The other is the inlet axial suction, which is convenient for vertical installation.

|
Model number |
Caliber |
Traffic volume |
Head lift |
Power |
Rotational speed |
Efficiency |
| 25-8-22-1.1 |
25 |
8 |
22 |
1.1 |
2825 |
38.5 |
| 32-12-15-1.1 |
32 |
12 |
15 |
1.1 |
2825 |
40 |
| 40-15-15-1.5 |
40 |
15 |
15 |
1.5 |
2840 |
45.1 |
| 40-15-30-2.2 |
40 |
15 |
30 |
2.2 |
2840 |
48 |
| 50-20-7-0.75 |
50 |
20 |
7 |
0.75 |
1390 |
54 |
| 50-10-10-0.75 |
50 |
10 |
10 |
0.75 |
1390 |
56 |
| 50-20-15-1.5 |
50 |
20 |
15 |
1.5 |
2840 |
55 |
| 50-15-25-2.2 |
50 |
15 |
25 |
2.2 |
2840 |
56 |
| 50-18-30-3 |
50 |
18 |
30 |
3 |
2880 |
58 |
| 50-25-32-5.5 |
50 |
25 |
32 |
5.5 |
2900 |
53 |
| 50-20-40-7.5 |
50 |
20 |
40 |
7.5 |
2900 |
55 |
| 65-25-15-2.2 |
65 |
25 |
15 |
2.2 |
2840 |
52 |
| 65-37-13-3 |
65 |
37 |
13 |
3 |
2880 |
55 |
| 65-25-30-4 |
65 |
25 |
30 |
4 |
2890 |
58 |
| 65-30-40-7.5 |
65 |
30 |
40 |
7.5 |
2900 |
56 |
| 65-35-50-11 |
65 |
35 |
50 |
11 |
2930 |
60 |
| 65-35-60-15 |
65 |
35 |
60 |
15 |
2930 |
63 |
| 80-40-7-2.2 |
80 |
40 |
7 |
2.2 |
1420 |
52 |
| 80-43-13-3 |
80 |
43 |
13 |
3 |
2880 |
50 |
| 80-40-15-4 |
80 |
40 |
15 |
4 |
2890 |
57 |
| 80-65-25-7.5 |
80 |
65 |
25 |
7.5 |
2900 |
56 |
| 100-80-10-4 |
100 |
80 |
10 |
4 |
1440 |
62 |
| 100-110-10-5.5 |
100 |
110 |
10 |
5.5 |
1440 |
66 |
| 100-100-15-7.5 |
100 |
100 |
15 |
7.5 |
1440 |
67 |
| 100-85-20-7.5 |
100 |
85 |
20 |
7.5 |
1440 |
68 |
| 100-100-25-11 |
100 |
100 |
25 |
11 |
1460 |
65 |
| 100-100-30-15 |
100 |
100 |
30 |
15 |
1460 |
66 |
| 100-100-35-18.5 |
100 |
100 |
35 |
18.5 |
1470 |
65 |
| 125-130-15-11 |
125 |
130 |
15 |
11 |
1460 |
62 |
| 120-130-20-15 |
125 |
130 |
20 |
15 |
1460 |
63 |
| 150-145-9-7.5 |
150 |
145 |
9 |
7.5 |
1440 |
63 |
| 150-180-15-15 |
150 |
180 |
15 |
15 |
1460 |
65 |
| 150-180-20-18.5 |
150 |
180 |
20 |
18.5 |
1470 |
75 |
| 150-180-25-22 |
150 |
180 |
25 |
22 |
1470 |
76 |
| 150-130-30-22 |
150 |
130 |
30 |
22 |
1470 |
75 |
| 150-180-30-30 |
150 |
180 |
30 |
30 |
1470 |
73 |
| 150-200-30-37 |
150 |
200 |
30 |
37 |
1480 |
70 |
| 200-300-7-11 |
200 |
300 |
7 |
11 |
970 |
73 |
| 200-250-11-15 |
200 |
250 |
11 |
15 |
970 |
74 |
| 200-400-10-22 |
200 |
400 |
10 |
22 |
1470 |
76 |
| 200-400-13-30 |
200 |
400 |
13 |
30 |
1470 |
73 |
| 200-250-15-18.5 |
200 |
250 |
15 |
18.5 |
1470 |
72 |
| 200-300-15-22 |
200 |
300 |
15 |
22 |
1470 |
73 |
| 200-250-22-30 |
200 |
250 |
22 |
30 |
1470 |
71 |
| 200-350-25-37 |
200 |
350 |
25 |
37 |
1980 |
75 |
| 200-400-30-55 |
200 |
400 |
30 |
55 |
1480 |
70 |
| 250-600-9-30 |
250 |
600 |
9 |
30 |
980 |
74 |
| 250-600-12-37 |
250 |
600 |
12 |
37 |
1480 |
78 |
| 250-600-15-45 |
250 |
600 |
15 |
45 |
1480 |
75 |
| 250-600-20-55 |
250 |
600 |
20 |
55 |
1480 |
73 |
| 250-600-25-75 |
250 |
600 |
25 |
75 |
1480 |
73 |
| 300-800-12-45 |
300 |
800 |
12 |
45 |
980 |
76 |
| 300-500-15-45 |
300 |
500 |
15 |
45 |
980 |
70 |
| 300-800-15-55 |
300 |
800 |
15 |
55 |
980 |
73 |
| 300-600-20-55 |
300 |
600 |
20 |
55 |
980 |
75 |
| 300-800-20-75 |
300 |
800 |
20 |
75 |
980 |
78 |
| 300-950-20-90 |
300 |
950 |
20 |
90 |
980 |
80 |
| 300-1000-25-110 |
300 |
1000 |
25 |
110 |
980 |
82 |
| 350-1100-10-55 |
350 |
1100 |
10 |
55 |
980 |
84.5 |
| 350-1500-15-90 |
350 |
1500 |
15 |
90 |
980 |
82.5 |
| 350-1200-18-90 |
350 |
1200 |
18 |
90 |
980 |
83.1 |
| 350-1100-28-132 |
350 |
1100 |
28 |
132 |
740 |
83.2 |
| 350-1000-36-160 |
350 |
1000 |
36 |
160 |
740 |
78.5 |
| 400-1500-10-75 |
400 |
1500 |
10 |
75 |
980 |
82.1 |
| 400-2000-15-132 |
400 |
2000 |
15 |
132 |
740 |
85.5 |
| 400-1700-22-160 |
400 |
1700 |
22 |
160 |
740 |
82.1 |
| 400-1500-26-160 |
400 |
1500 |
26 |
160 |
740 |
83.5 |
| 400-1700-30-200 |
400 |
1700 |
30 |
200 |
740 |
83.5 |
| 400-1800-32-250 |
400 |
1800 |
32 |
250 |
740 |
82.1 |
| 500-2500-10-110 |
500 |
2500 |
10 |
110 |
740 |
82 |
| 500-2600-15-160 |
500 |
2600 |
15 |
160 |
740 |
83 |
| 500-2400-22-220 |
500 |
2400 |
22 |
220 |
740 |
84 |
| 500-2600-24-250 |
500 |
2600 |
24 |
250 |
740 |
82 |
Installation instructions for LW vertical unobstructed sewage pump
1. The pump and pipeline should have their own supporting components, and the weight of the pipeline should not be applied to the pump.
2. In order to maintain convenience and ensure safe use, a regulating valve is installed on the inlet and outlet pipelines of the pump, and a pressure gauge is installed near the pump outlet to ensure that the pump operates within the rated head and flow range, ensuring the normal operation of the pump and improving its service life.
When installing the pump, it is necessary to tighten the foundation bolts to avoid the impact of vibration on the pump performance during start-up
Before installation, check the fastening and damage of the water pump and motor.
5. In order to prevent the pump from experiencing thermal deformation of the pipeline during the transportation of high-temperature liquids, the foot bolts of the pump seat are not fixed in turns. When the pipeline system expands and contracts, the pump can move together with the pipeline.
Precautions for using LW vertical non blocking sewage pump
1. Before using the sewage pump, carefully check whether the fasteners have moved or fallen off, and whether the pump has deformed or been damaged during transportation, storage, and installation.
2. After the sewage pump is started, the rotating square should rotate counterclockwise when viewed from the inlet. If the electric pump rotates in the opposite direction, simply swap any two-phase wires in the cable to adjust the wiring position.
3. It is not allowed to operate the electric pump in a low field range state for a long time (generally using a head not less than 60% of the rated head), and it is recommended to control it within the recommended range of swing head to prevent the pump from burning out the motor due to load.
4. The sewage pump should not operate under cavitation conditions to improve the service life of the pump. It is strictly prohibited to operate the pump without liquid, otherwise it is very easy to burn out the mechanical seals.
When the parts of the pump are made of cast iron and installed outdoors in winter. Attention should be paid to preventing breakage, and insulation should be applied when the temperature is particularly low.