LW vertical non blocking sewage pump
The LW vertical non blocking sewage pump is developed by introducing advanced foreign technology and absorbing and transforming it. All performance in
Product details

Overview of LW vertical unobstructed sewage pump

The LW vertical non blocking sewage pump is developed by introducing advanced foreign technology and absorbing and transforming it. All performance indicators meet the national standard for similar products. Due to the use of unique single (double) channel impellers, it has strong drainage capacity and can effectively pass through 5 times the diameter of the pump and solid particles with a diameter of 50% of the pump diameter. The dynamic seal adopts two sets of special hard alloy mechanical seal devices made of cast iron and stainless steel. This series of pumps adopts a unique impeller structure and mechanical seal, which can effectively transport solids and long fibers. Compared with traditional impellers, the impeller of this pump adopts a single channel or double channel form, which is similar to a curved pipe with the same cross-sectional size and has very good flow characteristics. Coupled with a reasonable volute chamber, the pump has high efficiency and the impeller has undergone dynamic and static balance tests, making the pump operate without vibration. The hydraulic performance of this pump is advanced and mature. After testing, all performance indicators of the product have reached the relevant standards and regulations. After its launch on the market, the product has been welcomed and praised by a large number of users for its unique efficacy, reliable performance, and stable quality.

LW vertical non blocking sewage pump product features

1. By adopting a unique single blade or double blade impeller structure, the passage capacity of pollutants is greatly improved, which can effectively pass through 5 times the diameter of fiber material and solid particles with a diameter of about 50% of the pump diameter;

2. The mechanical seal is made of hard all metal corrosion-resistant tungsten carbide material, which allows it to operate in the oil chamber for a long time and can ensure safe and continuous operation of the pump for more than 8000 hours;

3. The overall structure is compact, the volume is small, the noise is low, the energy-saving effect is significant, and the maintenance is convenient. At the same time, due to the use of standard Y series motors, it is easy for users to replace them;

4. The automatic control cabinet can automatically control the pump's over movement and stop according to the required liquid level changes, without the need for dedicated personnel to supervise, making it extremely convenient to use;

5. Square or circular installation systems can be equipped according to user needs, which brings great convenience to installation and maintenance. People do not need to enter the sewage pit for this purpose;

6. Can be used within the full head range while ensuring that the motor does not overload;

7. If the sewage pump is equipped with an outdoor motor, there is no need to build a pump room, and it can be directly installed outdoors to save costs;

8. The pump is a vertical structure.

LW vertical non blocking sewage pump product usage

The LW series non blocking sewage pump is suitable for the discharge of severely polluted wastewater in factories and commercial areas, sewage discharge stations in main residential areas, water distribution systems in urban sewage treatment plants, drainage stations in civil air defense systems, water supply equipment in water plants, sewage discharge in hospitals and hotels, municipal engineering construction sites, mining supporting machines, rural biogas digesters, farmland irrigation and other industries. It can also be used for conveying granular sewage and pollutants, as well as for clean water and weakly corrosive media.

Usage conditions of LW vertical unobstructed sewage pump

1. The operating environment temperature of the sewage pump is ≤ 40 ℃, and the humidity is ≤ 95%; If the altitude is ≤ 1000 meters, it should be raised when ordering.

2. The medium temperature shall not exceed 60 ℃, and the medium density shall be 1-1.3kg/dm3.

3. The use range of cast iron material is PH5-9.

4. 1Cr18Ni9Ti stainless steel material can be used with general corrosive media.

5. The altitude of the usage environment should not exceed 1000 meters. If it exceeds, it should be mentioned when placing an order to provide you with more reliable products.

Note: If the user has special requirements for temperature, medium, etc., please specify the detailed information of the conveying medium when ordering, so that our unit can provide more reliable products.

Structural Description of LW Vertical Non blocking Sewage Pump

The LW vertical sewage pump is a single suction volute pump equipped with non clogging and anti winding single (double) large channel impellers, which have good passing capacity. This series of pumps has two structural forms, one is that the motor is directly coaxial with the pump, and the other is that it is connected by a coupling, and the motor adopts a standard vertical motor. The structural diagram is as follows, and each structural form has two types of base connection forms. One is the inlet horizontal suction, which has a corner function and can be placed at 0 °, 90 °, 180 °, 270 ° according to usage requirements for pipeline connection. The other is the inlet axial suction, which is convenient for vertical installation.


Model number

Caliber
(mm)

Traffic volume
(m3/h)

Head lift
(m)

Power
(kw)

Rotational speed
(r/min)

Efficiency
(%)

25-8-22-1.1

25

8

22

1.1

2825

38.5

32-12-15-1.1

32

12

15

1.1

2825

40

40-15-15-1.5

40

15

15

1.5

2840

45.1

40-15-30-2.2

40

15

30

2.2

2840

48

50-20-7-0.75

50

20

7

0.75

1390

54

50-10-10-0.75

50

10

10

0.75

1390

56

50-20-15-1.5

50

20

15

1.5

2840

55

50-15-25-2.2

50

15

25

2.2

2840

56

50-18-30-3

50

18

30

3

2880

58

50-25-32-5.5

50

25

32

5.5

2900

53

50-20-40-7.5

50

20

40

7.5

2900

55

65-25-15-2.2

65

25

15

2.2

2840

52

65-37-13-3

65

37

13

3

2880

55

65-25-30-4

65

25

30

4

2890

58

65-30-40-7.5

65

30

40

7.5

2900

56

65-35-50-11

65

35

50

11

2930

60

65-35-60-15

65

35

60

15

2930

63

80-40-7-2.2

80

40

7

2.2

1420

52

80-43-13-3

80

43

13

3

2880

50

80-40-15-4

80

40

15

4

2890

57

80-65-25-7.5

80

65

25

7.5

2900

56

100-80-10-4

100

80

10

4

1440

62

100-110-10-5.5

100

110

10

5.5

1440

66

100-100-15-7.5

100

100

15

7.5

1440

67

100-85-20-7.5

100

85

20

7.5

1440

68

100-100-25-11

100

100

25

11

1460

65

100-100-30-15

100

100

30

15

1460

66

100-100-35-18.5

100

100

35

18.5

1470

65

125-130-15-11

125

130

15

11

1460

62

120-130-20-15

125

130

20

15

1460

63

150-145-9-7.5

150

145

9

7.5

1440

63

150-180-15-15

150

180

15

15

1460

65

150-180-20-18.5

150

180

20

18.5

1470

75

150-180-25-22

150

180

25

22

1470

76

150-130-30-22

150

130

30

22

1470

75

150-180-30-30

150

180

30

30

1470

73

150-200-30-37

150

200

30

37

1480

70

200-300-7-11

200

300

7

11

970

73

200-250-11-15

200

250

11

15

970

74

200-400-10-22

200

400

10

22

1470

76

200-400-13-30

200

400

13

30

1470

73

200-250-15-18.5

200

250

15

18.5

1470

72

200-300-15-22

200

300

15

22

1470

73

200-250-22-30

200

250

22

30

1470

71

200-350-25-37

200

350

25

37

1980

75

200-400-30-55

200

400

30

55

1480

70

250-600-9-30

250

600

9

30

980

74

250-600-12-37

250

600

12

37

1480

78

250-600-15-45

250

600

15

45

1480

75

250-600-20-55

250

600

20

55

1480

73

250-600-25-75

250

600

25

75

1480

73

300-800-12-45

300

800

12

45

980

76

300-500-15-45

300

500

15

45

980

70

300-800-15-55

300

800

15

55

980

73

300-600-20-55

300

600

20

55

980

75

300-800-20-75

300

800

20

75

980

78

300-950-20-90

300

950

20

90

980

80

300-1000-25-110

300

1000

25

110

980

82

350-1100-10-55

350

1100

10

55

980

84.5

350-1500-15-90

350

1500

15

90

980

82.5

350-1200-18-90

350

1200

18

90

980

83.1

350-1100-28-132

350

1100

28

132

740

83.2

350-1000-36-160

350

1000

36

160

740

78.5

400-1500-10-75

400

1500

10

75

980

82.1

400-2000-15-132

400

2000

15

132

740

85.5

400-1700-22-160

400

1700

22

160

740

82.1

400-1500-26-160

400

1500

26

160

740

83.5

400-1700-30-200

400

1700

30

200

740

83.5

400-1800-32-250

400

1800

32

250

740

82.1

500-2500-10-110

500

2500

10

110

740

82

500-2600-15-160

500

2600

15

160

740

83

500-2400-22-220

500

2400

22

220

740

84

500-2600-24-250

500

2600

24

250

740

82


Installation instructions for LW vertical unobstructed sewage pump

1. The pump and pipeline should have their own supporting components, and the weight of the pipeline should not be applied to the pump.

2. In order to maintain convenience and ensure safe use, a regulating valve is installed on the inlet and outlet pipelines of the pump, and a pressure gauge is installed near the pump outlet to ensure that the pump operates within the rated head and flow range, ensuring the normal operation of the pump and improving its service life.

When installing the pump, it is necessary to tighten the foundation bolts to avoid the impact of vibration on the pump performance during start-up

Before installation, check the fastening and damage of the water pump and motor.

5. In order to prevent the pump from experiencing thermal deformation of the pipeline during the transportation of high-temperature liquids, the foot bolts of the pump seat are not fixed in turns. When the pipeline system expands and contracts, the pump can move together with the pipeline.

Precautions for using LW vertical non blocking sewage pump

1. Before using the sewage pump, carefully check whether the fasteners have moved or fallen off, and whether the pump has deformed or been damaged during transportation, storage, and installation.

2. After the sewage pump is started, the rotating square should rotate counterclockwise when viewed from the inlet. If the electric pump rotates in the opposite direction, simply swap any two-phase wires in the cable to adjust the wiring position.

3. It is not allowed to operate the electric pump in a low field range state for a long time (generally using a head not less than 60% of the rated head), and it is recommended to control it within the recommended range of swing head to prevent the pump from burning out the motor due to load.

4. The sewage pump should not operate under cavitation conditions to improve the service life of the pump. It is strictly prohibited to operate the pump without liquid, otherwise it is very easy to burn out the mechanical seals.