Vortex Flowmeter、Electromagnetic Flowmeter、ultrasonic flowmeter、Gas turbine flowmeter、Elliptical gear flowmeter、
Precession vortex flowmeter、Metal tube float flowmeter、Mass flowmeter、Small flow micro flowmeter、Non standard customized flowmeter、Liquid turbine flowmeter、differential pressure transmitter、orifice meter、pressure transmitter、temperature transmitter、 Liquid level, material level, material level gauge、Insertion flowmeter、Flow totalizer、Anuba flowmeter、Quantitative flow controller、Submersible flowmeter、Remote video transmitter、PH/ORPMeasuring instrument、Universal flow display instrument、Ultrasonic Open Channel Flowmeter、Automatic monitoring recorder.
1、 Overview:Guangzhou Minghong Automation Instrument Co., Ltd
LDTThe series electromagnetic flowmeter can accurately measure the volumetric flow rate of various liquids and slurries, especially suitable for clean water, sewage, various highly corrosive fluids, food and beverages with hygiene requirements, and any concentration of slurry, pulp, cement slurry, etc.
Features: The inner wall of the sensor measuring tube is smooth and completely straight through; Multiple lining and electrode materials can be selected to meet the hygiene requirements, corrosion resistance, and wear resistance requirements of the tested medium; The output signal is proportional to the volumetric flow rate and is not affected by other physical properties of the measured medium, ensuring the measurement accuracy of volumetric flow rate; Range ratio up to1:40The minimum range is as low as0~0.5m/s.
2、 Technical data
Sensor caliber DN6-2000MM
Measuring medium liquid
Dielectric conductivity: ≥ 10 μ s/cm
Flow velocity range: 0.1-10 m/s
Range upper limit: 0.5-10 m/s
Basic error: 0.5% FS 1.0% FS
Work pressure: 0.6-4.0 Mpa
Medium temperature: -40~200oC
Environmental temperature:<50 ℃
Relative humidity:<90%
Protection level: IP65 (separate IP68)
Insulation grade E connecting flange; According to national standards
Measurement tube material: 1Cr18Ni9Ti stainless steel
Lining material: chloroprene rubber, polyurethane rubber, polytetrafluoroethylene, perfluoroethylene propylene
Electrode material: 1Cr18Ni9Ti (standard type) Hastelloy B Hastelloy C Titanium Tantalum Platinum
Output signal; 4~20mA DC
Signal load: ≤ 350 Ω or 700 Ω
Supply voltage; 220V AC
explain:Guangzhou Minghong Automation Instrument Co., Ltd
We can provide frequency output signals according to user ordering requirements, including active pulses and passive pulses(Optical coupling isolation)Two forms, the maximum output frequency value is4KHZ.
Active pulse: high level=11±1VLow level ≤0.5VLoad current: ≤20mA
Passive pulse: high level=External power supply(≤30V)-1V,Low level ≤0.5V,Load current ≤50mA
There are two ways to express the relationship between frequency signals and flow values:
1Pulse equivalent method -L/Pperhapsm3/PEach output pulse represents how many liters or how many cubic meters.
2Range frequency correspondence method - the maximum flow rate set by the instrument corresponds to the maximum frequency value output, for example, the instrument range is80 m3/hThe maximum frequency output is2KHZ .