main features
|
LCDG-DSSD206-3000 |
electrical parameter |
function |
|
|
solidtimemeasuremeasureprice |
Line voltage U |
ü |
|
|
|
Phase separation current I |
ü |
|
|
|
Total active power P |
ü |
|
|
|
Total reactive power Q |
ü |
|
|
|
Frequency F |
ü |
|
|
electricity ability |
ordinary instrument for drawing circles electricity ability
|
Combined active total electricity+kWh |
ü |
|
|
|
Positive active power+kWh |
ü |
|
|
|
Reverse active power consumption kWh |
ü |
|
|
|
Combined reactive power 1 electricity+kvarh |
ü |
|
|
|
Combination reactive power 2 electricity+kvarh |
ü |
|
|
|
Positive reactive power total+kvarh |
ü |
|
|
|
Reverse reactive power total amount - kvarh |
ü |
|
|
|
4-quadrant reactive power total kVarh |
ü |
|
|
feerateelectricityability |
Combined active total electricity+kWh |
ü |
|
|
|
Positive active power+kWh |
ü |
|
|
|
Reverse active power consumption kWh |
ü |
|
|
|
Combined reactive power 1 electricity+kvarh |
ü |
|
|
|
Combination reactive power 2 electricity+kvarh |
ü |
|
need measure |
Total maximum demand and occurrence time of positive active power |
ü |
|
|
|
Maximum total demand and occurrence time of reverse active power |
ü |
|
|
|
Total maximum demand and occurrence time of positive reactive power |
ü |
|
|
|
Total maximum demand and occurrence time of reverse reactive power |
ü |
|
|
electricitypowerarticlenature |
Voltage harmonic content (HRU) |
ü |
|
|
|
Current harmonic content HRI |
ü |
|
|
|
Voltage distortion HU (A) (total harmonic distortion rate) |
ü |
|
|
|
Current distortion HI (A) (total harmonic distortion rate) |
ü |
|
|
|
Active power distortion HP (A) (total harmonic distortion rate) |
ü |
|
|
|
Reactive power distortion HP (A) (total harmonic distortion rate) |
ü |
|
|
curve data |
Data storage and retrieval for 36 settlement days |
ü |
|
|
|
16 timed freezing data storage and reading |
ü |
|
|
|
16 instantaneous frozen data storage and reading |
ü |
|
|
|
64 daily frozen data storage and retrieval |
ü |
|
|
|
256 point freezing data storage and reading |
ü |
|
|
|
Storage and retrieval of 672 load record data |
ü |
|
|
|
672 harmonic data storage and reading |
ü |
|
|
communicationagreement |
DL/T645-2007 protocol |
ü |
|
|
|
Modbus RTU Powertrain Protocol |
ü |
|
|
displayindicate |
8-bit LCD, supporting loop display and button display |
ü |
|
|
|
Display variable ratio can be set |
ü |
|
|
|
Total harmonic distortion rate of phase separated voltage and current |
ü |
|
|
|
LED with or without power status indication |
ü |
|
|
|
LED pulse output |
ü |
|
|
other |
The direction of current penetration can be set |
ü |
|
|
|
High precision real-time clock with backup battery, supporting perpetual calendar |
ü |
|
|
|
Support zeroing of electrical energy |
ü |
|
|
characteristicfunction |
Line voltage and current can measure up to 31st harmonic |
ü |
|
|
|
Capable of conducting rate based electricity statistics |
ü |
|
major function
|
performance |
parameter |
|||
|
transport Entering Testing Quantity Show off Show |
electricity press |
measuring range |
80V~120V |
|
|
range |
110V |
|||
|
accuracy |
RMS accuracy: Level 0.5 |
|||
|
transformation ratio |
Variable ratio can be set(1~1000), default to 1 |
|||
|
electricity flow |
range |
5A (other ranges can be customized, and external transformers can be used to input mA level signals, which need to be specified in the supply requirements) |
||
|
accuracy |
RMS measurement (current accuracy: 0.5 level) |
|||
|
transformation ratio |
Variable ratio can be set(1~1000), default to 1 |
|||
|
frequency |
Three phase AC 50Hz voltage and current; |
|||
|
power |
Active accuracy: Level 1; Reactive power accuracy: Level 2 |
|||
|
Power factor |
Power factor accuracy: Level 0.5; |
|||
|
Electricity Source |
power supply |
Taken from line voltage, three-phase power supply |
||
|
power consumption |
<3VA |
|||
|
Losing Out Can be Compilation Cheng |
open up or clear out by poking or jabbing interrogate |
output interface |
RS-485 interface, two-wire system |
|
|
Communication Protocol |
MODBUS-RTU communication protocol, DLT645-2007 protocol |
|||
|
data format |
Can be set; 10 bits, 1 start bit 0, 8 data bits, 1 stop bit 1; Or 11 bits, which can be set by software for odd, even, or no verification; |
|||
|
COMMUNICATION RATE |
Baud rates of 1200, 2400, 4800, 9600, 19.2k, adjustable |
|||
|
display |
8-bit LCD segment code display |
|||
|
Active energy pulse output |
Pulse width 80ms ± 20ms, optically isolated |
|||
|
Ring The environment |
work environment |
Working temperature: -20~60 ℃ |
||
|
storage environment |
Storage temperature: -40~80 ℃ |
|||
|
relative humidity |
Relative humidity ≤ 95%, no condensation |
|||
|
An All in all |
pressure resistance |
Voltage signal and 485 withstand voltage>2kV, leakage current<5mA |
||
|
isolation |
Output, input, and power supply to casing>5M |
|||
|
Resistance Disturbing Degree |
Fast transient pulse |
>4kV |
||
|
Lightning Protection |
>4kV |
|||
|
air discharge |
>8kV |
|||