VIP member
JW-DA specific surface area analyzer
Performance parameter model JW-DXJW-DA Testing principle Low temperature nitrogen adsorption, Flow chromatography method Characteristics * * * Technol
Product details
performance parameter
| model | JW-DX | JW-DA |
|---|---|---|
| Testing principle | Low temperature nitrogen adsorption, flow chromatography method | |
| Method features | ***Technology. Using adsorption peaks, similar to the static capacity method, four samples were tested independently without interference, with sharp signal peaks The testing accuracy of 10m2/g small surface area samples has significantly improved |
Traditional detachment techniques. Using desorption peaks, the four samples are parallel and not independent, and the signal peaks are diluted, which is not suitable for precise testing of small surface area samples with a specific area of less than 10m2/g |
| Testing function | Comparison method with surface area test; Single point and multi-point BET specific surface area testing |
Comparison method with surface area test; Single point and multi-point BET specific surface area testing |
| Test gas | High purity nitrogen (99.999%)+high-purity helium (99.999%) | |
| Range of nitrogen partial pressure P/P0 | 0.05-0.35 (multi-point BET) | |
| Scope of testing | Specific surface area 0.01m2/G to no known upper limit, Not suitable for testing microporous materials |
Specific surface area 0.01m2/G to no known upper limit, Not suitable for testing microporous materials |
| Repetitive accuracy | Carbon black standard sample ≤± 1.0%; Highly consistent with the accuracy of static capacity method testing |
Carbon black standard sample ≤± 1.5%; |
| Analysis Station | 4 of them | |
| Testing efficiency | The comparative method takes about 5 minutes to test each sample; Multi point BET testing takes approximately 25 minutes for each sample |
The comparative method takes about 9 minutes to test each sample; Multi point BET testing takes about 30 minutes for each sample; |
| Host specifications | Length 610mm x width 460mm x height 680mm, weight approximately 48Kg; | |
| Environmental temperature requirements | Room temperature, it is recommended to equip with air conditioning | |
| Environmental humidity requirements | 10%-90% | |
| Power requirements | AC 220V ± 20V, 50/60HZ, * * power 300W, current 5A; | |
| Recommended application areas | Graphite, ternary materials, lithium iron phosphate, lithium manganese oxide, lithium cobalt oxide and other positive and negative electrode materials for batteries; Pharmaceutical excipients; Metal powder; Metal oxide powder; Rare earth luminescent materials; Nano calcium carbonate; wait |
Lithium iron phosphate cathode material; Titanium dioxide; Inorganic non-metallic materials such as nano calcium carbonate; wait |
| Degassing station | Standard configuration includes 3 stations at the same location, which can simultaneously perform vacuum heating and degassing of three samples; An external 4-station vacuum heating and degassing machine can also be optionally selected; |
|
Online inquiry
