MBSeries mechanical diaphragm type (Italian OBL metering pump, original imported metering pump,:)
MC model:
MB11 PP,MB16 PP,MB23 PP,MB31 PP,MB50 PP,MB75 PP,MB101 PP,MB120 PP,MB155 PP
MB11 AA,MB16 AA,MB23 AA,MB31 AA,MB50 AA,MB75 AA,MB101 AA,MB120 AA,MB155 AA
Diaphragm type, economical, durable and compact metering pump
When the mechanical diaphragm works, it has the same stroke displacement as a piston pump while isolating the process end liquid from the mechanical transmission system
The pump has fewer components, making it easy to repair and maintain
The unique mechanical diaphragm design of OBL (already obtained) ensures a linear relationship between the conveying flow rate and stroke ratio Actual traffic
Internationally, it is not affected by changes in work pressure
The unique pressure resistant diaphragm of OBL makes the pump leak free
High level of work safety
Spring reset mechanism
Zui high flow rate: 15 l/h stroke length: 2mm, 4mm
Technical Parameter
The maximum back pressure 12~7 Bar Zui high traffic 11~50 rise/time(STROKE LENGTH 2mm) 50~155 rise/Time (stroke length) 4mm) electrical machinery Three phase, power:0.2/0.3kW、230/400VNumber of electrodes:4 Extreme, regulatory standards:IP-55、I.CL.F、S1、IEC 34-1 Single phase, power:0.24/0.37kW、230VNumber of electrodes:4 Extreme, regulatory standards:IP-55、I.CL.F、S1、IEC 34-1 net weight 10~25 kilogram Stroke adjustment Manual: Fine tuning knob(1)Scale 0~10 Corresponding traffic 0%~100% (2)The suggested range for traffic adjustment is 10%~100%(Precision within this range:±2%) The following are remote control devices (optional) (1)Electric:ZType electronic drive device, capable of receiving external signals (Current:-4~20mA、0~20mA、20~4mA、0~10V)The(Pulse:-0.2~2Hz、-1.5~30Hz) (2)Pneumatic:WPneumatic device (air pressure) 3~15psi) (3)RS-485 open up or clear out by poking or jabbingMessage Protocol pump head PP Material (optional)changeFor stainless steel) The suction and discharge interfaces can be threaded or flanged (optional) Maximum self-priming height:1.5 rice Zui High Liquid Temperature:PP 45℃withoutstainless steel 90℃
Pressure flow meter
model | Number of strokes (This time)/Minutes) | Zui high traffic (Rising)/When) | The maximum back pressure (Bar) | connector | ||||
thread | flange | |||||||
3PH | 1PH | PP | A | PP | A | |||
MB11 | 36 | 11 | 12 | 12 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB16 | 50 | 16 | 12 | 12 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB23 | 70 | 23 | 12 | 12 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB31 | 95 | 31 | 10 | 10 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB50 | 155 | 50 | 10 | 10 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB75 | 70 | 75 | 8 | 8 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB101 | 95 | 101 | 8 | 8 | 3/8”BSPF | DN15-1/2”ANSI | ||
MB120 | 115 | 120 | 7 | 7 | 3/8”BSPF | 1/2”BSPF | DN15-1/2”ANSI | |
MB155 | 155 | 155 | 7 | 7 | 3/8”BSPF | 1/2”BSPF | DN15-1/2”ANSI |