Product Introduction
1、 Introduction
American Spike SupermarketInfrared oil condition monitoring deviceQ410 is versatile in high-performance applicationsInfrared spectroscopy analyzerOn the basis of this, application development was carried out for the oil monitoring industry, including OilA analysis control and analysis software, as well as a designed injection method (Flip Top Cell). The oil analysis technology accumulated by Speechao for many years was organically combined with new analytical instruments to achieve direct quantitative determination of oil aging and pollution status, improve the detection accuracy and repeatability of the instrument, and reduce the requirements for instrument operation and result analysis on operators.
Q410Used for qualitative and quantitative analysis of the aging degree and pollution status of oil, based on JOAP and DIN standards and optimized for design, it meets the ASTM E2412 standard (Fourier transform infrared spectroscopy trend analysis detection method for oil lubrication state), and can quickly detect multiple physical and chemical indicators such as oxidation degree, nitrification degree, vulcanization degree, micro water, coolant (pollution), fuel dilution (pollution), residual carbon, and anti-wear additive loss of oil, fully meeting the requirements for oil state monitoring in equipment maintenance.

Q410Specially designed for in use oil analysis and testing (developed for in use oil liquid analysis), with simple operation and no need for extensive professional training for operators. At the same time, it has the characteristics of small size, small footprint, built-in design flip top cell, no solvent required, simple cleaning, simple injection, wide applicability, built-in fixed interferometer, no software or manual calibration required, and optional automatic injection system (to achieve analysis process automation), making it an ideal choice for oil condition monitoring and lubricant quality control laboratories.
IIInfrared oil condition monitoring deviceQ410 Product Features
1. The instruments, sample tanks, and management software are specifically designed and developed for the needs of in use oil detection;
2. Based on JOAP and DIN standards and optimized for design, in accordance with ASTM E2412 standard;
3. Quantitative detection of total acidity/alkalinity (TAN/TBN) with built-in optimization algorithm;
4. Design a reverse loading sample pool that does not require solvents and is easy to clean;
5. Can directly measure high viscosity oils (without the need for oil sample preparation);
6. Fixed interferometer, no software or manual calibration required;
7. Fully enclosed design, with strong practicality in the environment;
8. Desktop, small in size, easy to transport;
9. Specially designed for in use oil analysis software;
10. Fast testing speed;
11. Easy replacement of infrared light source;
12. Built in instrument status monitoring module ensures high reliability operation of the instrument;
13. Bruker OPUS OilAnalysis software works in parallel;
14. Computer control, connected and controlled through Ethernet interface.
IIIQ410 Product Application
1. Application scope: Mineral or synthetic lubricants, biodiesel, and grease used in key oil equipment such as gearboxes, engines, transformers, hydraulic systems, turbines, etc;
2. Output results: TAN (mgKOH/g), TBN (mgKOH/g), oxidation degree (abs/mm2), nitrification degree (abs/mm2), sulfidation degree (abs/mm2), micro water (ppm), ethylene glycol (w%), residual carbon (w%), mixed oil pollution (w%), loss of antioxidant additives (% residual amount), loss of anti-wear additives (w%);
3. Standard methods: ASTM E2412, JOAP, DIN;
4. Cleaning solvent: Manual injection: No need;
5Automatic injection: Pentane.
4、 Q410 Optical System
1Manual injection: Zinc arsenide (ZnSe) reverse transfer cell (transmission method), window, spectrometer, wavenumber range: 6000-500 cm-1;
2. Automatic injection (optional): Zinc arsenide (ZnSe) material transmission carrier cell, window, spectrometer, wavenumber range: 6000-500 cm-1;
3. Sample pool optical path length: 100um;
4. Interferometer: ROCKSOLID ™, * Collimation;
5. Detector: DTGS, thin film pyroelectric;
6. Frequency accuracy: better than 2cm-1, 0.9 cm-1 (optional);
7. Signal to noise ratio:>30000:1 (1.5 x 10-5 AU noise) peak -;
8. Peak value, 4 cm-1 resolution
5、 Q410 Parameter Introduction
1. Using parameters
1)Working temperature: 18-35 ° C;
2) Temperature difference: 2 ° C/day;
3) Relative humidity (non condensing): less than 80%;
4) Installation location: enclosed room;
5) Altitude: below 2000 meters.
2. User interface parameters
1)Software/Operating System: A software system for the Windows operating system;
2) External control computer;
3) Control interface: Ethernet;
4)Power parameters:Power supply: 240VAC, 50 Hz;
5) Fuse current: 1.3A.
3. Mechanical parameters
1)Size: 22 (height) x 30 (length) x 25 (width) centimeters;
2) Weight: approximately 7kg;
6、 Q410 Main consumables
1FL306: Cleaning cotton paper;
2. FL310: Calibration standard oil;
3. P-11052: Pipette (60ul).