- product description
GC-9560-HGHigh purity hydrogen analysis helium ion chromatographSuitable for high-purity hydrogen gasO2(Ar)、N2、 CH4、 CO、CO2classThe detection of trace impurities is carried out using a highly sensitive helium ionization (PDIHID) detector equipped with central cutting and blowback technology. The instrument is equipped with an injection switching valve with a blowback protection gas path and an imported helium purifier. Through non dead volume sampling or online injection methods, high-purity hydrogen gas can be obtained in one goThe above-mentioned impuritiesDetection, with a detection limit of ppb and a repeatability RSD of ≤ 1%.
The national standard GB/T 28726-2012 "Gas Analysis - Helium Ionization Gas Chromatography Method", which was mainly drafted by Hua Ai Chromatography, has been officially announced and implemented since February 1, 2013.
1、 Applicable standards:
- GB/T3634.2-2011 "Pure Hydrogen, High Purity Hydrogen, and Ultra Pure Hydrogen"
- GB/T 28726-2012 "Gas Analysis - Helium Ionization Gas Chromatography Method"
IIHigh purity hydrogen analysis helium ion chromatographTechnical parameters:
1. Detection limit (ppb):
General impurities | |||||
Types of groceries |
O2(Ar) |
N2 |
CH4 |
CO |
CO2 |
inspectMeasurement limit |
10 |
10 |
5 |
25 |
5 |
2. Temperature control indicators:
- Column box: 8 ℃ -400 ℃ at room temperature with an accuracy of ± 0.1 ℃
- Sample injector: Accuracy ± 0.1 ℃ at room temperature between 8 ℃ and 400 ℃
- Detector: Accuracy ± 0.1 ℃ at room temperature between 8 ℃ and 400 ℃
- Temperature control quantity: eight channels
- Program heating: 8th order
- Heating rate: 1 ℃~40 ℃
- Cooling rate: within 7 minutes (350 ℃ to 50 ℃)
3. Helium ionization detector (PDD):
- Discharge mode: Pulse discharge
- Baseline noise: ≤ 0.1mv
- Baseline drift: ≤ 0.5mv/30min
- Detection limit: ≤ 1.0 × 10-10g/ml
4. Carrier gas purifier:
- Purified gases: He, Ar, Ne, Kr, Xe, Rn
- Operating pressure: 1000Psi
- Gas removal: H2、 O2, N2, CO, CO2, CH4, H2O, NO, NH3, CF4, etc
- Residual concentration: ≤ 10pppb
5. Workstation performance:
- Communication interface: RS232/USB interface
- High precision: 24 bit high-precision A/D
- Resolution: ± 1UV
- Input voltage range: -5mv to+1v
- Sampling frequency: high 20 times/second
- Dynamic range: 106
- Integral sensitivity: 1 μ v • sec
- Linearity:<± 0.1%.
- Reproducibility: 0.06%.
6. Other parameters: size, weight, power supply:
- Dimensions: Width 655mm x Height 500mm x Depth 480mm
- Weight:~48kg
- Power supply: 220V ± 22V, 50Hz, power ≥ 2kW
3、 System configuration:
(1) GC-9560-HG helium ion chromatograph (2) helium ionization detector (PDDID)
(3) Central cutting system (4) multi column box system
(5) Helium Purifier (6) Standard Gas
(7) Chromatography Column (9) Oxygen Adsorption and Reduction System
(10) Special pressure reducing valve for carrier gas (11), no dead volume dedicated sampling valve
(12) GC-9560V4.0 Reverse Chromatography Workstation