VIP member
High and low temperature cycle integrated machine
Can fully design and produce non-standard products according to user requirements
Product details
High and low temperature cycle integrated machine


The compressor can be directly started for cooling at 200 degrees Celsius
★ Can design and produce non-standard products completely according to user requirements
Application areas:
Biochemical field: rotary evaporator, Abbe refractometer, polarimeter, atomic absorption spectroscopy ICP-MS、ICP、 Nuclear magnetic resonance CCD、 Biological fermentation tanks, chemical reactors, etc
◆ Medical field: Superconducting magnetic resonance, linear accelerator CT、 Low magnetic field nuclear magnetic resonance, X-ray machine, microwave therapy machine, medical cold cap, cooling blanket, etc
◆ Physical and chemical fields: lasers, magnetic fields, various molecular pumps, diffusion pumps, ion pumps, and various water-cooled equipment used in the materials field
Materials field: electron microscopy, X-ray diffraction, X-ray fluorescence, vacuum sputtering electroplating, vacuum coating machine, ICP etching, various semiconductor equipment, fatigue testing machine, chemical deposition system, atomic deposition system, etc
Product Introduction:
Our company's series of high and low temperature cycle integrated machines adopt the latest international advanced fluorine free refrigeration system, and the main components are directly imported, with stable and reliable performance. Widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, medicine and health, life sciences, light industry and food, physical property testing and chemical analysis, universities, enterprise quality inspection and production departments, providing users with a controlled cold and hot liquid environment with uniform and constant temperature during work. It can be used for direct heating or cooling, as an auxiliary heating or cooling temperature source, such as temperature control for reaction vessels, fully automatic synthesis instruments, extraction and condensation devices
Main features:
◎ Fully enclosed fluorine free environmentally friendly compressor refrigeration system, with multiple protections such as overheating and overcurrent
◎ Maximum feature: The compressor can be directly started for cooling at 200 degrees without damaging the compressor
◎ Imported latest microcomputer intelligent control, large screen high brightness LCD screen, bilingual display in Chinese and English
Built in 1/3B high-precision PT100 temperature sensor
The inner liner and countertop are made of high-quality S304 brushed stainless steel panel
Dual use of water and oil, temperature range: optional -50~200 ℃, high and low temperature can be freely selected (medium can be selected according to temperature range: pure water, methyl silicone oil, etc.)
◎ Humanized R-rounded design structure for front panel and countertop to avoid scratches
◎ External circulation function: The centrifugal jet circulation pump can draw out the constant temperature liquid in the tank, establish a second constant temperature field, and control the external experimental container of the machine
Internal circulation function: Adopting a non heat centrifugal circulation pump to avoid the influence of traditional water pumps on the tank temperature field due to their own heat generation. The internal circulation system is designed based on the principle of porous U-shaped reflux circulation, achieving turbulent and highly uniform flow and temperature fields inside the tank
The cold liquid in the tank can be introduced into the experimental container outside the cooling machine, or low-temperature and constant temperature experiments can be conducted directly in the tank
The drainage system can meet the needs of various laboratories and enterprises for liquid exchange production
◎ Vertical standard with universal wheel feet
◎ Safety protection device:
1. Equipped with power-off protection function
2. Equipped with upper and lower temperature alarm setting function
3. Low water level protection and alarm function
4. Temperature runaway protection and alarm function
5. The heating tube has low water level anti dry burning and explosion-proof functions
◎ Digital display resolution: 0.01 ℃
◎ Temperature fluctuation value: ± 0.05 ℃
◎ The temperature range can be expanded to:- 120~200℃
Technical parameters:
Optional Function Guide:
1. Optional extended external PT100 temperature sensor, which can detect and control the temperature of the external system in real time during external circulation
2. Optional built-in temperature control program with 1-30 segments, capable of automatic program temperature control and real-time display of the set temperature time program running status
3. Optional RS232 or RS485 communication interface, easy to connect to the upper computer, with Modbus RTU communication protocol
4. Optional design and installation of magnetic stirring system, which can directly stir the liquid sample in the beaker placed in the constant temperature bath working room with magnetic stirring, without the need for an external vertical mixer, reducing redundant operations
5. Optional cooling coils built into the tank can quickly cool and control the exothermic reaction of the system
6. Optional height adjustable immersion platform for easy adjustment of the liquid level of the immersed sample
7. Optional horizontal design, featuring compact structure, lowered center of gravity, and strong stability
Manufacturer friendly reminder - When selecting a thermostatic bath, the following points should be considered:
1. Firstly, what is the range of temperature required for use? What medium is used as the temperature field carrier, and the medium used varies depending on the temperature range. The medium is generally selected according to the temperature range: ethylene glycol mixed with water (low temperature), alcohol (ultra-low temperature), pure water (5-95 ℃), imported dimethyl silicone oil (suitable for high and low temperatures), etc
2. Choose the appropriate capacity of the constant temperature bath based on your actual situation. The correct calculation method for effective working volume is: the opening size of the working bath plus the bath depth, in millimeters
3. It is a requirement for the temperature uniformity of the constant temperature bath temperature field. Our company divides it into two categories: 1. Ordinary type: ± 0.05 ℃. 2、 Ultra high precision type: ± 0.0020 ℃
4. What is the maximum head of the external circulation function based on the usage situation


The compressor can be directly started for cooling at 200 degrees Celsius
★ Can design and produce non-standard products completely according to user requirements
Application areas:
Biochemical field: rotary evaporator, Abbe refractometer, polarimeter, atomic absorption spectroscopy ICP-MS、ICP、 Nuclear magnetic resonance CCD、 Biological fermentation tanks, chemical reactors, etc
◆ Medical field: Superconducting magnetic resonance, linear accelerator CT、 Low magnetic field nuclear magnetic resonance, X-ray machine, microwave therapy machine, medical cold cap, cooling blanket, etc
◆ Physical and chemical fields: lasers, magnetic fields, various molecular pumps, diffusion pumps, ion pumps, and various water-cooled equipment used in the materials field
Materials field: electron microscopy, X-ray diffraction, X-ray fluorescence, vacuum sputtering electroplating, vacuum coating machine, ICP etching, various semiconductor equipment, fatigue testing machine, chemical deposition system, atomic deposition system, etc
Product Introduction:
Our company's series of high and low temperature cycle integrated machines adopt the latest international advanced fluorine free refrigeration system, and the main components are directly imported, with stable and reliable performance. Widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, medicine and health, life sciences, light industry and food, physical property testing and chemical analysis, universities, enterprise quality inspection and production departments, providing users with a controlled cold and hot liquid environment with uniform and constant temperature during work. It can be used for direct heating or cooling, as an auxiliary heating or cooling temperature source, such as temperature control for reaction vessels, fully automatic synthesis instruments, extraction and condensation devices
Main features:
◎ Fully enclosed fluorine free environmentally friendly compressor refrigeration system, with multiple protections such as overheating and overcurrent
◎ Maximum feature: The compressor can be directly started for cooling at 200 degrees without damaging the compressor
◎ Imported latest microcomputer intelligent control, large screen high brightness LCD screen, bilingual display in Chinese and English
Built in 1/3B high-precision PT100 temperature sensor
The inner liner and countertop are made of high-quality S304 brushed stainless steel panel
Dual use of water and oil, temperature range: optional -50~200 ℃, high and low temperature can be freely selected (medium can be selected according to temperature range: pure water, methyl silicone oil, etc.)
◎ Humanized R-rounded design structure for front panel and countertop to avoid scratches
◎ External circulation function: The centrifugal jet circulation pump can draw out the constant temperature liquid in the tank, establish a second constant temperature field, and control the external experimental container of the machine
Internal circulation function: Adopting a non heat centrifugal circulation pump to avoid the influence of traditional water pumps on the tank temperature field due to their own heat generation. The internal circulation system is designed based on the principle of porous U-shaped reflux circulation, achieving turbulent and highly uniform flow and temperature fields inside the tank
The cold liquid in the tank can be introduced into the experimental container outside the cooling machine, or low-temperature and constant temperature experiments can be conducted directly in the tank
The drainage system can meet the needs of various laboratories and enterprises for liquid exchange production
◎ Vertical standard with universal wheel feet
◎ Safety protection device:
1. Equipped with power-off protection function
2. Equipped with upper and lower temperature alarm setting function
3. Low water level protection and alarm function
4. Temperature runaway protection and alarm function
5. The heating tube has low water level anti dry burning and explosion-proof functions
◎ Digital display resolution: 0.01 ℃
◎ Temperature fluctuation value: ± 0.05 ℃
◎ The temperature range can be expanded to:- 120~200℃
Technical parameters:
| Model number | Temperature range (℃) | Temperature uniformity (Horizontal/Vertical ℃) Ethylene glycol |
Inner groove volume (mm) (Length X Width X Slot Depth) |
Total capacity (L) | Work slot opening (mm2) | Cooling capacity (W) Pure water at 20 ℃ | External circulation pump flow rate (L/min) |
| VKGD-0506 | -5~200 | ±0.05 | 275×195×120 | 6 | 180×140 | 600 | 13 |
| VKGD -0510 | -5~200 | ±0.05 | 275×195×180 | 10 | 180×140 | 900 | 13 |
| VKGD -0515 | -5~200 | ±0.05 | 300×250×200 | 15 | 235×160 | 1500 | 13 |
| VKGD -0520 | -5~200 | ±0.05 | 300×250×270 | 20 | 235×160 | 2000 | 13 |
| VKGD -0530 | -5~200 | ±0.05 | 440×325×210 | 30 | 310×280 | 2700 | 13 |
| VKGD -0550 | -5~200 | ±0.05 | 500×340×300 | 50 | 350×300 | 4000 | 13 |
| VKGD -05100 | -5~200 | ±0.05 | 625×400×400 | 100 | 400×380 | 7000 | 13 |
| VKGD -1006 | -10~200 | ±0.05 | 275×195×120 | 6 | 180×140 | 800 | 13 |
| VKGD -1010 | -10~200 | ±0.05 | 275×195×180 | 10 | 180×140 | 1200 | 13 |
| VKGD -1015 | -10~200 | ±0.05 | 300×250×200 | 15 | 235×160 | 1800 | 13 |
| VKGD -1020 | -10~200 | ±0.05 | 300×250×270 | 20 | 235×160 | 2300 | 13 |
| VKGD -1030 | -10~200 | ±0.05 | 440×325×210 | 30 | 310×280 | 3000 | 13 |
| VKGD -1050 | -10~200 | ±0.05 | 500×340×300 | 50 | 350×300 | 4300 | 13 |
| VKGD -10100 | -10~200 | ±0.05 | 625×400×400 | 100 | 480×380 | 7500 | 13 |
| VKGD -2006 | -20~200 | ±0.05 | 275×195×120 | 6 | 180×140 | 1200 | 13 |
| VKGD -2010 | -20~200 | ±0.05 | 275×195×180 | 10 | 180×140 | 1600 | 13 |
| VKGD -2015 | -20~200 | ±0.05 | 300×250×200 | 15 | 235×160 | 2200 | 13 |
| VKGD -2020 | -20~200 | ±0.05 | 300×250×270 | 20 | 235×160 | 2700 | 13 |
| VKGD -2030 | -20~200 | ±0.05 | 440×325×210 | 30 | 310×280 | 3400 | 13 |
| VKGD -2050 | -20~200 | ±0.05 | 500×340×300 | 50 | 350×300 | 4700 | 13 |
| VKGD -20100 | -20~200 | ±0.05 | 625×400×400 | 100 | 480×380 | 7900 | 13 |
| VKGD -3006 | -30~200 | ±0.05 | 275×195×120 | 6 | 180×140 | 1700 | 13 |
| VKGD -3010 | -30~200 | ±0.05 | 275×195×180 | 10 | 180×140 | 2100 | 13 |
| VKGD -3015 | -30~200 | ±0.05 | 300×250×200 | 15 | 235×160 | 2700 | 13 |
| VKGD -3020 | -30~200 | ±0.05 | 300×250×270 | 20 | 235×160 | 3200 | 13 |
| VKGD -3030 | -30~200 | ±0.05 | 440×325×210 | 30 | 310×280 | 3900 | 13 |
| VKGD -3050 | -30~200 | ±0.05 | 500×340×300 | 50 | 350×300 | 5200 | 13 |
| VKGD -30100 | -30~200 | ±0.05 | 625×400×400 | 100 | 480×380 | 8400 | 13 |
| VKGD -4006 | -40~200 | ±0.05 | 275×195×120 | 6 | 180×140 | 2300 | 13 |
| VKGD -4010 | -40~200 | ±0.05 | 275×195×180 | 10 | 180×140 | 2900 | 13 |
| VKGD -4015 | -40~200 | ±0.05 | 300×250×200 | 15 | 235×160 | 3400 | 13 |
| VKGD -4020 | -40~200 | ±0.05 | 300×250×270 | 20 | 235×160 | 3900 | 13 |
| VKGD -4030 | -40~200 | ±0.05 | 440×325×210 | 30 | 310×280 | 4600 | 13 |
| VKGD -4050 | -40~200 | ±0.05 | 500×340×300 | 50 | 350×300 | 5800 | 13 |
| VKGD -40100 | -40~200 | ±0.05 | 625×400×400 | 100 | 480×380 | 9000 | 13 |
| VKGD -5006 | -50~200 | ±0.05 | 275×195×120 | 6 | 180×140 | 2700 | 13 |
| VKGD -5010 | -50~200 | ±0.05 | 275×195×180 | 10 | 180×140 | 3400 | 13 |
| VKGD -5015 | -50~200 | ±0.05 | 300×250×200 | 15 | 235×160 | 3900 | 13 |
| VKGD -5020 | -50~200 | ±0.05 | 300×250×270 | 20 | 235×160 | 4500 | 13 |
| VKGD -5030 | -50~200 | ±0.05 | 440×325×210 | 30 | 310×280 | 5200 | 13 |
| VKGD -5050 | -50~200 | ±0.05 | 500×340×300 | 50 | 350×300 | 6400 | 13 |
| VKGD -50100 | -50~200 | ±0.05 | 625×400×400 | 100 | 480×380 | 9800 | 13 |
Optional Function Guide:
1. Optional extended external PT100 temperature sensor, which can detect and control the temperature of the external system in real time during external circulation
2. Optional built-in temperature control program with 1-30 segments, capable of automatic program temperature control and real-time display of the set temperature time program running status
3. Optional RS232 or RS485 communication interface, easy to connect to the upper computer, with Modbus RTU communication protocol
4. Optional design and installation of magnetic stirring system, which can directly stir the liquid sample in the beaker placed in the constant temperature bath working room with magnetic stirring, without the need for an external vertical mixer, reducing redundant operations
5. Optional cooling coils built into the tank can quickly cool and control the exothermic reaction of the system
6. Optional height adjustable immersion platform for easy adjustment of the liquid level of the immersed sample
7. Optional horizontal design, featuring compact structure, lowered center of gravity, and strong stability
Manufacturer friendly reminder - When selecting a thermostatic bath, the following points should be considered:
1. Firstly, what is the range of temperature required for use? What medium is used as the temperature field carrier, and the medium used varies depending on the temperature range. The medium is generally selected according to the temperature range: ethylene glycol mixed with water (low temperature), alcohol (ultra-low temperature), pure water (5-95 ℃), imported dimethyl silicone oil (suitable for high and low temperatures), etc
2. Choose the appropriate capacity of the constant temperature bath based on your actual situation. The correct calculation method for effective working volume is: the opening size of the working bath plus the bath depth, in millimeters
3. It is a requirement for the temperature uniformity of the constant temperature bath temperature field. Our company divides it into two categories: 1. Ordinary type: ± 0.05 ℃. 2、 Ultra high precision type: ± 0.0020 ℃
4. What is the maximum head of the external circulation function based on the usage situation
Online inquiry