The Herocell 240H carbon dioxide incubator, relying on years of production experience and design breakthroughs, has demonstrated some key characteristics in practical cell culture applications. Providing the optimal cell growth environment and effective pollution control technology, the thoughtful design is suitable for more important applications, and it is easy to operate and monitor, allowing you to invest more time in your research goals.
Herocell 240H CO2 incubator adopts a 6-sided direct heating temperature control method, which can provide precise temperature control for your cell culture environment, with a temperature uniformity of ± 0.1 ℃; The 180 ° C dry heat high-temperature sterilization function can easily achieve complete sterilization with just one click, effectively avoiding the risk of bacterial contamination in cell culture; Infrared (IR) CO2Concentration detector accurately controls CO inside the box2Concentration; The touch control panel allows for easy viewing of historical data curves and is equipped with a USB interface for one click export of historical data. Our reliable direct heating carbon dioxide incubator adopts a unique HEPA air filtration system built-in to the cabin, which can sustainably protect the cultivation environment from harmful pollutants in the air. It provides high-temperature sterilization as needed to simplify daily cleaning and maintenance.
Product advantages:
6-sided heated direct heating cabin
The 248L large capacity compartment provides ample cultivation space and an ideal environment for cell culture applications
The 6-sided heating method, with an efficient and high-performance heating system distributed on the surface of each cultivation chamber, provides a highly uniform temperature distribution for the entire cultivation chamber, making the temperature of the entire cultivation chamber more uniform. After stabilization, the temperature field uniformity inside the chamber can reach ± 0.1 ℃
Standard right side door opening method, optional left and right door opening direction according to requirements
The polished stainless steel integrated inner cavity has rounded corners for easy cleaning
The detachable tray can be flexibly combined, and the independent humidity tray can be removed or placed according to needs
The cabin is equipped with a fan that gently blows air, ensuring even distribution throughout the cabin and maintaining a consistent cultivation environment
Stainless steel partitions and brackets are sturdy and durable, and can be disassembled without the need for tools
❏ No condensation water technology
The non condensation water control technology ensures that even when the humidity tray generates high humidity, condensation water will not be generated above the cabin, providing maximum protection for cell and tissue culture and avoiding the danger of condensation formation. Turbulent chamber ventilation ensures a constant and uniform cell culture environment
❏ 180 ° C dry heat high temperature sterilization
Based on the required 180 ° C dry heat high-temperature sterilization, cleaning work is simplified without the need for separate high-temperature and high-pressure disinfection and reassembly of components, effectively improving work efficiency
The 180 ° C dry heat high-temperature sterilization system can effectively eliminate bacteria, mold, yeast, and mycoplasma on the surface of the inner cavity
ISO Level 5 HEPA filtered airflow system
The cabin is equipped with a HEPA air filtration system that continuously filters the air throughout the entire cabin
Within 5 minutes after opening the door, achieve ISO level 5 air quality
Provide continuous protection by reducing the adhesion ability of air pollutants on internal surfaces
Imported sensors and probes designed for precise monitoring
⊙ Infrared (IR) CO2Sensors provide stable monitoring when humidity and temperature are unpredictable, effectively avoiding measurement bias caused by frequent door opening and closing
Best suited for sensitive applications and remote monitoring, or situations where frequent opening of the incubator is required
Temperature probe with overheat protection provided
The rH monitor can be used to monitor humidity levels to prevent the water tray from evaporating (optional)
Active Airflow Technology
The incubator is equipped with a fan assisted airflow circulation, which can achieve rapid recovery and strict consistency. Our airflow pattern is specifically designed to evenly distribute key environmental conditions such as temperature, gas exchange, and humidity
The built-in fan in the chamber can gently blow filtered humid air throughout the entire chamber, ensuring that all cells, regardless of their placement, have the same cultivation environment conditions and will not lose water
5-inch LCD touch control screen
⊙ Intuitive control and easy operation, capable of displaying real-time operating curves and historical operating curves
The installation position above the door is convenient and easy to control, and the capacitive touch screen is sensitive to touch and provides a good control experience
Sound and visual alarms, on-screen menu prompts
Intelligent remote monitoring function (optional)
⊙ Intelligent remote control operation, real-time monitoring of machine operation status
| model | Herocell 240H |
| Control Interface | 5-inch LCD touch screen |
| Temperature control mode | PID control mode |
| Temperature control range | Room temperature+5 ℃~60 ℃ |
| Temperature display resolution | 0.1℃ |
| Temperature Stability | ±0.1℃ |
| Uniformity of temperature field | ±0.3℃ at 37℃ |
| Power | 1000W |
| Timing | 0-999.9 hours |
| Internal dimensions (width x depth x height) | 630 x 600 x 670mm |
| Dimensions (width x depth x height) | 800 x 660 x 1000mm |
| Box volume (L) | 248L |
| CO2measuring principle | Infrared (IR) detection |
| CO2Control range | 0~20% |
| CO2display resolution | 0.10% |
| CO2supply | Maximum overpressure of 10 bar (1MPa) Suggest using 0.5~1bar (0.05~0.1MPa) |
| relative humidity | <95% at 37℃ |
| Humidity display (optional) | Real time display of box humidity |
| Remote control (optional) | Remote wireless viewing and control of operational status |
| HEPA filtration | ISO Level 5, 5 minutes |
| Sterilization method | 180 ° C dry heat high temperature sterilization |
| Temperature recovery time |
≤10 min (Open the door for 30 seconds, room temperature 25 ℃, set value 37 ℃) |
| Gas concentration recovery time |
≤5 min (Set value of 5% after opening the door for 30 seconds) |
| Data export interface | USB interface |
| Historical data storage | 25W pieces of information |
| Ambient Temperature | 10℃~30℃ |
| power supply | 220~240V/50~60Hz |
| weight | 116kg |
| Scalability | Up to 2 units can be stacked |
modelHerocell 240HThe corresponding configuration is:
| Serial Number | name | quantity | unit |
| 1 | host | 1 | tower |
| 2 | hepa filter | 1 | individual |
| 3 | intake filter | 1 | individual |
| 4 | 304 stainless steel humidifying plate | 1 | individual |
| 5 | 304 stainless steel pallet | 3 | piece |
| 6 | power line | 1 | individual |
| 7 | Paper materials such as instruction manuals | 1 | share |