Hash online water quality analyzer and accessories consumables HACH Order Number DESCRIPTION
MODBUS module Running-9013200 SC200 domestic communication module, default 4-20mA configuration. If there are communication requirements, an additional domestic communication module can be added
Hash Online PHAnalyzer SC200 LXV404.99.00102 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
HHACH differential pH electrode PHD ™ PD1R1 Range: 0-14PH, -5~+95 ℃, with 4.5m original cable
Ryton electrode protective cover 1000F3374-003
PH powder pack (4,7,10) Running-PH4710
Immersion installation bracket RNMH434A00B
Automatic electrode cleaning device RN1000A3335-006
Stainless steel circulation pool RNMH314N4MZ Material: 304SS
PH Salt Bridge SB-P1SV-CN Sensor material: PEEK
PH Salt Bridge SB-R1SV-CN Sensor material: Ryton
electrolyte 25M1A1025-115CN
PH electrolyte PH-10PH-500 500ML
O-ring of PH/ORP 5H1306
PH standard solution (pH=4500mL) 2283449 User defined, it is recommended to calibrate on a monthly basis
PH standard solution (pH=7500mL) 2283549 User defined, it is recommended to calibrate on a monthly basis
PH standard solution (pH=10500mL) 2283649 User defined, it is recommended to calibrate on a monthly basis
PH standard solution set Running-PH4710 PH standard solution set (4.01,7.00,10.01) -500ml
ORP standard solution (200mV, 500mL) 25M2A1001-115 User defined
ORP standard solution (600mV, 500mL) 25M2A1002-115CN User defined
Hash transmitter Polymetrion9500 9500.99.00704 Output: 4-20mA, Power Supply: 220VAC, Display: LCD
PH composite electrode PC1R1A Range: 0-14PH, 0~105 ℃, with 4.5m original cable
PH powder pack (4,7,10) Running-PH4710
Immersion installation bracket FGMH432G
DSC-PH-302sensor DSCPH030201 Range: 0-14PHStandard cable length:10rice
Stainless steel circulation pool RNMH313N3NZ
Hash Online PH Analyzer SC200 LXV404.99.00102 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
HACHEncapsulated differential pH electrode 6028P0 Range: 0-14PH, -5~+95 ℃, with 15m original cable
LCP electrode protective cover 60A2F1278
PH powder pack (4,7,10) Running-PH4710
Immersion installation bracket RNMH434B
Automatic electrode cleaning device RN1000A3335-003
PVC circulation pool RNMH376
Hash Online PH Analyzer SC200 LXV404.99.00102 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD, immersion installation
pH electrode EL5600-2-KZ0-(S)
Original item number5600-5F(S)
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃
pH electrode EL5602-0-KZ-(S)
Original item number 5602-5F (S)
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃, drug-resistant electrode
pH electrode EL5603-0-KZ-(S)
Original item number5603-5F(S)
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~95 ℃, drug-resistant and high-temperature resistant electrode
Immersion installation bracket RNHC703C-2-400A Pole material PVC, pole length1.5rice
Hash Online PH Analyzer SC200 LXV404.99.00102 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD, pressurized, flowing or plug-in installation
pH electrode EL5610-2-KZ0-(S)
Original item number5610-5F(S)
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃, pressure type
pH electrode EL5612-0-KZ-(S)
Original item number5612-5F(S)
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃, resistant pressure electrode
pH electrode EL5613-0-KZ-(S)
Original item number5613-5F(S)
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~95 ℃, high temperature and drug resistant pressure electrode
Flow type sheath DK-882-PP Main liquid PP
, O-ring fluororubber; Flange installation, user specified flange standard, pressure resistance 0.6MPAOnline insertion and removal of protective sleeves(domestic
)
(Instrument air pressurization is required on site) DK-SSH-PP
The main liquid is PP, with an insertion depth of 100-300, threaded, and flange installation DN ≥ 50; Pipeline pressure less than 0.4MPa, temperature below 80 degrees Celsius Plug in protective sheath (domestic) DK-880F-PP
Flange installation, user specified flange standard, pressure resistance of 0.6MPA; Main liquid PP , O-ring fluororubber Hash Online ORP Analyzer SC200
LXV404.99.00102 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD HACH differential ORP electrode PHDTM
RD1R5 Range: -1500~+1500mV, -5~+95 ℃, with 4.5m original cable
Ryton electrode protective cover 1000F3374-003 ORP standard solution
ORP200-500 500mlImmersion installation bracketR
N MH434A00B ORP online analyzer Polymetron9500
9500.99.00704 Output: 4-20mA, Power Supply: 220VAC, Display: LCD ORP composite electrode
RC1R5N Range: -2000~+2000mv, with 4.5m original cable ORP standard solution
ORP200-500 500mlImmersion installation bracketR
NMH432GHash Online ORP/T analyzer SC200
LXV404.99.00102Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDH ACH Encapsulated differential ORP electrode
2028R0 Range: -2000~+2000mv, -5~+95 ℃, with 7.5m original cable
LCP electrode protective cover 60A2F1278 ORP standard solution
ORP200-500 500mlImmersion installation bracketR
NMH434B Hash online sludge concentration meter S olitax ™ sc
LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDTurbidity of Ts Line SC / Suspended solids sensor
LXV423.80.10101 Range: 0.001-4000NTU, 0.001mg/L-50g/L, accuracy: 5%, with 10m original cable, material: PVC, with automatic cleaning mechanical scraper Suspension optical path calibration solution
TU667-500 500mlImmersion installation bracketR
N LZX414.00.20000Stainless steel flow-through installation bracket5738100 R
N Material: 304SS Self cleaning scraper blade
LZX050 Replace once a year, silicone resin, set of 5 pieces Suspension optical path calibration solution
TU667-500 500ml 800NTU turbidity standard solution 500ml
2660549-CN 5733000 Two bottles are required for one calibration
Calibration toolkit Purchase upon initial order (including one calibration bucket, one 500mL bottle) 800NTU TablCal standard solution and a probe holder
Hash online sludge concentration meter Solitax ™ scLXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD Turbidity of Ts Line SC /Suspended solids
sensor LXV423.99.12100 Range: 0.001-4000NTU, 0.001mg/L-50g/L, accuracy: 5%, with 10m original cable, material: PVC
Suspension optical path calibration solution TU667-500500mlImmersion installation bracket
R N LZX414.00.20000
Hash Online Dissolved Oxygen Analyzer SC200LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD LDO II
Dissolved oxygen electrode 9020000SLURange: 0-20mg/l, with 10m original cable, fluorescence method9253000
Rod type installation bracket RN9253500
Automatic electrode cleaning device RN9253100
Floating ball installation bracket 9021100
R N Sensor fluorescent cap
HACH Online Dissolved Oxygen Analyzer SC200 LXV404.99.00102 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
5500 Clark Dissolved Oxygen Electrode 5540D0A
Range: 0-40mg/l, with 4.5m original cable, polarographic method Immersion installation bracket FGMH276R00F
Membrane head replacement component 5500A1020-001 Including a pre installed semi permeable membrane, electrode, electrolyte, and O-ring
HACH Conductivity Analyzer SC200 3422 LXV404.99.00202
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD TriE Conductivity Sensor 0-200000us/cm, Equipped with 6m cable
3700E Conductivity Sensor 3725E2T20G Range: from 0-200 μ s/cm to 0-2000000 us/cm, with 6m cable
Conductivity standard solution EC1000-500500mlPVC circulation pool
R NMH538N3NZImmersion installation bracket
R 9302700 NMH432GHash Online COD Analyzer CODmaxIIRange:10-5000mg/lAccuracy:10%Output:4-20mACommunication:
MODBUS/RS485Power supply:220VAC C ODreagent
LCW420 H ACH Producer
COD reagent TZ-HC-CODHash formula, third-party preparationSample Preprocessor
R N CY-A
reagent LCW420
Tested every 2 hours and calibrated and cleaned every 7 days, it can take about 80 days. I have randomly brought a set COD reagent TZ-HC-COD
One year maintenance of components YY0000090 One set per year, I have already brought one set randomly
Sulfuric acid valve YY0000288 One set per year
Dissolving tank 8839100 YY000012224Change every 24 monthsPISTON PUMPevery
Change once a month 4555058
For the first timeWhen purchasing a piston pump, it is necessary to equip it with Fixed parts of piston pump H
ACH online COD analyzer SC200 LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
UVAS Plus SC Organic Matter Sensor (2mm) LXV418.99.20002
Range: 0-1500m-1SAC, can be converted to COD value, no reagent required, with 10m original cable Immersion installation bracket LZY714.99.53520
COD standard solution PH-1COD100-500 500ml
Cleaning brush(2mm optical path) (5 pieces)LZX012 Replace one set per year and bring one set randomly; C
OD analyzer SC200 LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDUVAS eco sc organic matter sensorLXV443.80.10002Range:5-1500m-1SAC, can be converted intoCOD
Value, no reagent required, belt
10m Original cable Immersion installation bracket
LZY714.99.53520 COD standard solution PH-1COD100-500
500ml Cleaning brush LZX148
Replace one set per year and bring one set randomly; 1mm optical path length, UVAS and UVAS Eco universal, 5 pieces
Potassium permanganate index analyzer COD-203 COD203A-2-2C12A11AY0011Range: 0-20mg/L, Reproducibility: ± 1% FS, Output: 4-20mA, Communication: RS485, Power Supply: 220VACPotassium permanganate reagent
TZ-HC-CODMN Sample Preprocessor
RN CY-B Potassium permanganate reagent
TZ-HC-CODMNP1 Pump diaphragm (APN-085LV) 125A114
1 year P1 Spring valve (APN-085LV)
125A1131 year Air pump muffler 136A791
1 year 116E032 Silicon tube
φ6 xφ 8116C008 ` Flexible hose with a diameter of 10 x 14.5
7 per yearsolenoid valve (SV5~10,12~14) 126A135
1 year solenoid valve (SV2~4,7)
126A2821 year Platinum electrode (0.65m) EL2059CE
1 yearreference electrode #4216 (0.3m) EL4216AE
1 year PFA Pipe diameter 2 x 3
116D30213m/year activated carbon 136A075
1 yearPFA 116E023 Pipe diameter 4 x 6
116D3034 months 116E065 Uni
Pipe diameter 5 x 9 116E061 1 year
Uni Pipe diameter 7 x 15
0.2 meters per yearUni Tube 116E028 0.3 meters per year
Connecting pipe 7230570K 1 year
Uni Pipe diameter 6 x 8.5
6 months Sleeve (Z-union 8 PP) 117B858
6 months Online Oil Analyzer SC200 for WaterLXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
FP360 SC Water Oil Sensor LXV441.99.21102 Range: 0-500 μ g/l and 0-5000 μ g/l
(PAH), 0-15mg/l, and 0-150 mg/l (oil); With 10m cable 8646400
Immersion installation bracket R
N LZX914.99.11110 Hash Ammonia Nitrogen Online Analyzer Amtax NA8000
NA8000.02 Range: 0.020mg/L~1000.0mg/L, accuracy: when 0.020mg/L~100.0mg/L: 3%; When 80.00
~1000mg/L: ≤± 10%, power supply: 220VAC, communication: RS485 Modbus, display: color touch screen 4-20 mA analog signal output I/O module Ammonia nitrogen chemical reagents (A and additives, B,C)
LCW937-CN 8646400
Ammonia nitrogen standard solution cleaning solution set TZ-PH-NH40550
Blank standard solution+standard solution 1 (5mg/L)+Standard solution 2 (50mg/L)+Cleaning solution Ammonia nitrogen preprocessor
CY-B-03 Hash Ammonia Nitrogen Online Analyzer Amtax NA8000
NA8000.01 Range: 0.020mg/L~100.0mg/L, accuracy: 3%, power supply: 220VAC, communication: RS485 Modbus, Display: Color touch screen
4-20 mA analog signal output I/O module Ammonia nitrogen chemical reagents (A and additives, B,C)
LCW937-CN Ammonia nitrogen standard solution cleaning solution set TZ-PH-NH40550
Blank standard solution+standard solution 1 8860100 (5mg/L)+Standard solution 2 (50mg/L)+Cleaning solution
Ammonia nitrogen preprocessor CY-B-03 Chemical reagents (A and additives, B,C)
LCW937-CN Change every 2 months, bring a set randomlyStandard solution cleaning solution set TZ-PH-NH40550
Ammonia nitrogen reagent and standard solution kit TZ-HC-NH4-NA8000
Change every 2 months, bring a set randomly 6860100
maintenance kit Replace one set every six months and bring one set randomly Ammonia nitrogen online analyzer SC200
LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDAISE sc ammonia nitrogen electrodeL
XV440.99.10012 Range: 0-1000mg/l NH4-N, Accuracy: 5% ± 0.2mg/l of measured value, with 10m cable
cleaning device LZY706 Self cleaning air compressor
Ammonia nitrogen standard solution PH-1NH410-500
500ml
Handrail installation tool kit
R
N LZX414.00.80000-1 1/4 Handrail installation tool kit
RNLZX414.00.80000 When not equipped with a self-cleaning device, choose
Calibration cylinder LZY6941502 Replace 3 sets per yearSC1000 transmitterLXV402.80.00004LXV400.99.10172
YAB021 Output: 4-channel 4-20mA, communication: MODBUS/RS485, power supply: 220VAC, touch screen display, can connect 4 sensors
Amtax SC ammonia nitrogen analysis module 6157400-CN Range: 0.05-20mg/L, accuracy: 3% ± 0.05mg/L
Sample Preprocessor FGCY-B
SC200 transmitter LXV404.99.0 Output:
2 routes 4-20mA, Communication: MODBUS/RS485, Power supply: 220VAC, display: Chinese LCD
Power module 2894354 LQV155.99.00002
AMTAX sc reagent, 2500 mL 2894452-CN three
Replace once a month, bring a set randomly Ammonia nitrogen reagent TZ-HC-NH4-SC
1 mg/L NH4-N ammonia nitrogen standard solution, 2000mL 2894154-CN three
Replace once a month, bring a set randomly 6182500 Ammonia nitrogen standard solution
PH-1NH41-2000 2000ml 10 mg/L NH4-N ammonia nitrogen standard solution, 2000mL
three Replace once a month, bring a set randomly Ammonia nitrogen standard solution
PH-1NH410-2000 2000ml AMTAX sc cleaning solution, 250 mL2894246-CNthreeReplace once a month, bring a set randomlyAmmonia nitrogen cleaning solutionHC-3NH4-250250mlAmtax SC electrolyte and membrane, 11 mLeveryReplace along with the membrane every 2 to 3 months Comes with three bottles of electrolyte and three films, one set is randomly includedAmmonia nitrogen electrode for AMTAX sc analyzer
LZY069 Replace once a year
Air pump head for AMTAX sc analyzer LZY181 Replace once every 1-2 years
Total Phosphorus Analyzer PHOSPHAX ® Σsigma LPV341.80.20010
Range:0.01-5.0mg/l Accuracy: 2%10Output:24-20mA
Communication: MODBUS RS485
Power Supply: 220VAC
Sample Preprocessor FGCY-B 18Reagent (for 0-5mg/L)
LCW823 The total phosphorus reagent has a 3-month warranty period after configuration, with a measurement interval of 10 minutes. A set of reagents will be replaced every 3 months. You can also use the program to test every 2 hours, and one set of reagents can be used for one year. Mix according to the required ratio, and store the unmixed separately. Randomly bring a set. 18Total phosphorus reagent (low)
TZ-HC-TP-L Standard solution 24(2 mg/l)
LCW824 Measurement Interval Minute, replace within a yearSet, bring one set randomlyTotal phosphorus standard solutionPH-1TP2-500500mlOne year maintenance toolkitLZP959Replace one set per year, bring one set randomlyReaction tankLZP856
Replace one set every month and bring one set randomly Mixing motor
LZP864 Replace one set every month and bring one set randomly Reactor base
LZP845 Replace one set every month and bring one set randomly
Total Phosphorus Analyzer PHOSPHAX ® Σsigma
LPV341.80.21010 Range: 0.01-10.0mg/l
Accuracy: 2%
Output: 4-20mA Communication:
MODBUS RS485
Power supply: 220VAC 4Sample Preprocessor
CY-B Reagent (for 0-10mg/L)
LCW893 The total phosphorus reagent has a 3-month warranty period after configuration, with a measurement interval of 10 minutes. A set of reagents will be replaced every 3 months. You can also use the program to test every 2 hours, and one set of reagents can be used for one year. Mix according to the required ratio, and store the unmixed separately. Randomly bring a set. 1Total phosphorus reagent (high)
TZ-HC-TP-H Other as above
Online orthophosphate analyzer SC200 LXV404.99.00502 1Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
Power module LQV155.99.00002 PHOSPHAX sc orthophosphate analysis module
6159600-CN Range: 0.05-15.0mg/L, accuracy: 2% ± 0.05mg/LSample Preprocessor CY-B
Reagent, 2000ml 2825254-CN Replace one set every month and bring one set randomly
Orthophosphate reagent TZ-HC-P-phosphaxsc
Cleaning solution, 1000ml 2825352-CN Replace one set annually and bring one set randomly
Phosphorus cleaning solution, 1000ml HC-3P-1000
Pump head, used for air pumps LZY181 Replace one set annually
SC200 transmitter LXV404.99.00502
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD 6860100
Nitratax Plus SC nitrate nitrogen sensor L XV417.99.20002
Range: 0.1-50mg/l, accuracy: 3%, with 10m original cable Nitrous nitrogen standard solution
PH-1NO320-500 500mlImmersion installation bracketLZY714.99.53220 Cleaning brush (2mm optical path) (5 pieces)
LZX012 Replace one set per year, bring one set randomly Online nitrate nitrogen analyzer SC200
LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD NISE sc nitrate nitrogen electrode LXV440.99.20012
Range: 0-1000mg/L NO3-N, Accuracy: 5% ± 0.2mg/l of measured value, with 10m cable cleaning device
LZY706 Self cleaning air compressor
Nitrous nitrogen standard solution 6860100
PH-1NO320-500 500ml Handrail installation tool kit
FGLZX414.00.80000-1 1/4 Handrail installation tool kit
F GLZX414.00.80000(When not equipped with a self-cleaning device, choose)
Calibration cylinder LZY694 Replace 3 sets per year
Online ammonia nitrogen/nitrate nitrogen analyzer SC200 LXV404.99.00502
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD AN-ISE sc ammonia nitrogen/nitrate nitrogen two in one electrode LXV440.99.00012
Range: 0-1000mg/l NH4-N、0-1000mg/L NO3-N, Accuracy: 5% ± 0.2mg/l of measured value, with 10m cable
cleaning device LZY706
Self cleaning air compressor Ammonia nitrogen standard solution PH-1NH410-500
500ml Nitrous nitrogen standard solution
PH-1NO320-500 500ml
Handrail installation tool kit R N
LZX414.00.80000-1 1/4 Handrail installation tool kit
RNLZX414.00.80000 (When not equipped with a self-cleaning device, choose)
Calibration cylinder LZY694 Replace 3 sets per year
Hash Total Phosphorus and Nitrogen Analyzer NPW-160H NPW160H-0-11EA00 Total phosphorus: 0-0.5mg/L; Total nitrogen: 0-20mg/L; Municipal sewage outlets for surface water, tap water, and standard discharge
Total phosphorus and total nitrogen reagent TZ-PH-TPTN
Sample pretreatment system CY-B HACH Total Phosphorus and Nitrogen Analyzer NPW-160H
NPW160H-0-11GE00 Total phosphorus: 0~10mg/L; Total nitrogen: 0~50mg/L; Used in the sewage industry Total phosphorus and total nitrogen reagent
TZ-PH-TPTN Sample pretreatment system CY-B
Online TP/TN analyzer NPW-160H NPW160H-0-11HF00 Total phosphorus: 0-20mg/L (factory setting); Total nitrogen: 0~100mg/L (factory setting); Repeatability: 3%, output: 2-channel 4-20mA, communication: RS485
(MODBUS/RTU), Power supply: 220VAC
Total phosphorus and total nitrogen reagent
2976300 TZ-PH-TPTN2Sample pretreatment systemCY-BTotal phosphorus and total nitrogen reagentTZ-PH-TPTNReplace one set every month (range and standard solution values need to be provided)20mm syringe component5461210KOne per yearpistonOne per yearSyringe kit (set of 5)6804420KHalf a year one set
Pump hose 125B724
Half a year one set PTFE hose (one meter) 116D002
Buy 10 meters, one year PFA pipe with a diameter of 2 × 3 meters 116D302
Buy 10 meters, one year Hash ultrasonic sludge interface analyzer SC200 transmitter+SONATAX sc ultrasonic sensor+elbow type installation hardware
Output: road
4-20mA Power supply: 220VAC
, Display: Chinese LCD Range:
0.2-12m Accuracy: 0.1m
, with 10m cable
Install fixed accessories FGLZY428
Sensor Wiper Scraper LZX328
Replace one set per year, I have already brought one set randomly HACH Ultrasonic Open Channel Flow Meter SC200 LXV404.99.00302
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD U53S Ultrasonic Flow Sensor
U53S033 Range: 0.25-6m, accuracy: ± 1mm, with 10m cable Sensor Installation Kit
3004A0017-001 AS950 all-weather refrigerated sampler ASA.CXXX3X41XX
24/7 refrigerated AS950 sampler, Vinyl 8572400 Base, 24 bottles of 1L polyethylene sampling bottles, 230V power supply, USB interface
AS950 all-weather refrigerated sampler ASA.CXRX3X41XX All-weather AS950 sampler, Vinyl
Base 230V power supply, 24 1L polyethylene sampling bottles, communication: RS485 8560400 AS950 refrigerated sampler
ASR.CXXX2X41XX Refrigerated AS950 sampler, Vinyl Base, 24 bottles of 1L polyethylene sampling bottles, 230V power supply, USB interface
AS950 refrigerated sampler 8572400 ASR.CXRX2X41XX
Refrigerated AS950 sampler, Vinyl Base, 24 bottles of 1L polyethylene sampling bottles, 230V power supply, USB interface, MODBUS AS950 portable sampler
ASP.CXXXS141XX 8560400 Battery Charger
8753500EU AS950 portable sampler ASP.CXRXS141XX
9184 RS485 Battery Charger 8753500EU
Pump pipe 4.6m 4600-15
Replace two sets per year Hash online residual chlorine analyzer SC200 controller LXV404.99.00502
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD CL17sc residual chlorine analyzer Range: 0-10mg/L; Installation kit with pressure regulator, no reagents
Residual chlorine reagent 2556900-CN Replace one set every month and bring one set randomly;
CL17sc tube kit Replace one set per year and bring one set randomly; Online Total Chlorine Analyzer SC200 Controller
LXV404.99.00502 9160200 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
CL17sc Total Chlorine Analyzer 9160600 Range: 0-10mg/L; Installation kit with pressure regulator, no reagents
Total Chlorine Reagent 2557000-CN Replace one set every month and bring one set randomly;
CL17sc tube kit Replace one set per year and bring one set randomly; HACH online residual chlorine analyzer SC200 controller
LXV404.99.00502 9180900 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
SC residual chlorine sensor 9181400 LXV432.99.00001
Range: 0.005-20ppm (mg/L) HOCl, accuracy: 2% or ± 10ppb HOCl Residual chlorine film, 9184sc
Z09184=A=3500 Replace the film every six months. This order number includes 4 pieces of film, which can be used for two years 9184sc electrolyte
Z09184=A=3600 Replace every 6 months pH electrode
Z368417,00000 Replace once a year, bring one randomly Hash online residual chlorine analyzer SC200 controller
LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD CLF10 sc residual chlorine analyzer panel
LXV45A.99.13022 Range: 0-10ppm, accuracy: ± 3% Membrane replacement component for residual chlorine sensor
Replace every 6 months Electrolyte for residual chlorine sensor, 100mL Replace every 6 months
Online Total Chlorine Analyzer SC200 Controller LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
CLT10 sc Total Chlorine Analyzer Panel LXV45B.99.13022 Range: 0-10ppm, accuracy: ± 10%
Membrane replacement component for total chlorine sensor Replace every 6 months Electrolyte for total chlorine sensor, 100mL
1Replace every 6 monthsOnline chlorine dioxide analyzer SC200 controller 1895000 LXV404.99.00502
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD 9187sc chlorine dioxide sensor LXV434.99.00001CN
Range: 0-2mg/l, accuracy: 5% 9187sc membrane, 4 pieces Z09187=A=3500
Replace the film every six months. This order number includes 4 pieces of film, which can be used for two years 8630300 9187sc electrolyte, 100ml
Z09187=A=3600CN Replace every 6 months Electrode, replacement, 9187sc
Z09184=A=1001 Replace once a year, bring one randomly Online Ozone Analyzer SC200 Controller
LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD 9185sc ozone sensor
LXV433.99.00001 Range: 0-2ppm, accuracy: ± 3% or ± 10ppb, take the larger value 9185sc membrane, 4 pieces
Z09185=A=3500Replace the film every six months. This order number includes 4 pieces of film, which can be used for two years 9185sc electrolyte, 100ml Z09185=A=3600
Replace every 6 months HACH online low range turbidity meter (SC200+1720E) 2978100-CN
Range: 0.001-100NTU, accuracy: 0 to 40NTU. The range is ± 2% of the reading or ± 0.02NTU, whichever is larger. The range of 40 to 100NTU is ± 5% of the reading. Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD720E 4503400 Lamp components
Replace once a year, bring one randomly; 4000NTU STABLCA standard solution, 500mL 246149-CN
Change one set every year 20NTU Stable standard solution
2660153-CN Change one set every three months SC200 transmitter+TU5300sc online laser turbidity meter
Range: 0-700NTU. Accuracy: When 0-40NTU, it is ± 2% or ± 0.01NTU (whichever is greater) of the reading; At 40-1000NTU, it is ± 10% of the reading. Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD StablCal packaging standard, 10, 20, 600 NTU
LZY898-CN Replace one set every year
Replacement of desiccant LZY876
Replace one set every year 5705001 Online measurement of small bottles
LZY834 5410002Replace once every 1-2 years Fiber scraper brush, self-cleaning module
LZQ176 5740001Suggest replacing it every three months S
S7 High Range Turbidity Meter SC200 Controller LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
SS7 turbidity sensor 5742100 LPV431.80.00002
Range: 0.01-9999.9NTU, Accuracy: 0.01 to 2000NTU Range is ± 5% of reading, 2000 to 9999NTU Range is ± 10% of reading 5744800 SS7
lamp assembly Replace once a year, bring one randomly; 4000NTU STABLCA standard solution, 500mL
246149-CN Calibration frequency is determined according to user needs Sea Turbidity Meter SC200
LXV404.99.00502 Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD
ULTRATURB Seawater SC Sensor LPV415.99.22002
Range: 0-1000NTU, with 5m cable and automatic cleaning system Calibration cleaning components (mandatory for calibration)LZV451Fumalazine, 4000NTU, 100ML
246142-CN Filter, used for zero calibration LZV325
Particle counter 2200 PCX Counting range: 2-750 microns, 8-channel analog signal input and output, flow rate control device
Hardness Monitoring and Alarm Instrument SP510 -CN
Monitoring alarm point: 2mg/L, accuracy: ± 10%, alarm output: 1 SPDT relay, power supply: 220VAC Online fluoride analyzer CA610
-CN Range: 0.1-10mg/L, Accuracy: ± 10% or ± 0.10mg/L, whichever is greater, Output: 4-20mA, Power Supply: 220VAC, Display: LCD
CA610 complete set of reagents: including: reagent 1 (TISAB), standard sample 1, and standard sample 2 2816900-CN Change one set every month
One year spare parts Change one set every year, bring one set randomly sensor assembly
Including ion selection and pH sensors, sensor heads, and filling fluids Fluoride ion analyzer FBM-160 FBM160-1-AA0A0BB0B
Measurement range: 0~99.9mg/L (factory setting: 0~20), power supply: AC 90~264V、50/60Hz, No RS-232C interface, wall mounted installation, electrical connection: G1/2, temperature display range: 0~50 degrees ELCP fluoride ion selective electrode
ELCP-81-5F Cable length: 5m Fluoride ion standard solution (1000mg/L, 500mL)
PH-1F1000-500 Ionic strength regulator (PH5-AB, 500mL) PH-8F-500
Immersion installation bracket R N
MH432G 116E065 Online hexavalent chromium analyzer HMA-CR6
HMA-CR6 Range: 0.01~2 (low), 0.02~5 Mg/L (high), measurement lower limit: 0.001 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface Pure water bucket (including sensor) 7321530K
Waste liquid tank (including sensor) 7321540K
Hexavalent chromium reagent TZ-HC-CR6-HMA
Sample Preprocessor CY-B
20mL syringe assembly 5461210K
1 year Syringe piston assembly 7319030K
6 months Pump pipe 125B724
6 months O-ring component 7319040K
1 year Check valve component 6879770S
6 months PFA hose with a diameter of 2 and a diameter of 3 116D302
1 year sleeve 117B001
1 year 116E065 Resin hose
1 year Lubricant components 6952210K
6 months Online total chromium analyzer HMA-TCR HMA-TCR
Range: 0.02-2 (low), 0.03-5 Mg/L (high), measurement lower limit: 0.002 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface Pure water bucket (including sensor)
7321530K Waste liquid tank (including sensor)
7321540K Total chromium reagent
TZ-HC-TCR-HMA Sample Preprocessor CY-B
20mL syringe assembly 5461210K 1 year
Syringe piston assembly, 3/6 months 7319030K 6 months
Pump pipe 125B724 1 year
O-ring component 7319100K 1 year
PFA hose with a diameter of 2 and a diameter of 3 116D302 1 year
sleeve 116E065 117B001
1 year Resin hose 1 year
Lubricant components 6952210K 6 months
Online total copper analyzer HMA-TCU HMA-TCU
Range: 0.05-3 (low), 0.15-10 Mg/L (high), measurement lower limit: 0.01 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface Pure water bucket (including sensor)
7321530K Waste liquid tank (including sensor)
7321540K Total copper reagent TZ-HC-TCU-HMA
Sample Preprocessor CY-B 20mL syringe assembly
5461210K 1 year Syringe piston assembly
7319030K 6 months Pump pipe
125B724 1 year O-ring component
7319040K 1 year PFA hose with a diameter of 2 and a diameter of 3
116D302 116E065 1 year
sleeve 117B001 1 year
Resin hose 1 year Lubricant components
6952210K 6 months
Online Manganese Analyzer HMA-TMN HMA-TMN
Range: 0.1-5 (low), 0.5-20 Mg/L (high), measurement lower limit: 0.05 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface Pure water bucket (including sensor)
7321530K Waste liquid tank (including sensor) 7321540K
Total Manganese Reagent TZ-HC-TMN-HMA Sample Preprocessor
CY-B 20mL syringe assembly 5461210K
1 year Syringe piston assembly 7319030K
6 months Pump pipe 125B724
1 year O-ring component 7319040K
1 year 116E065 PFA hose with a diameter of 2 and a diameter of 3
116D302 1 year sleeve
117B001 1 year Resin hose
1 year Lubricant components 6952210K
6 months HMA-TNI Total Nickel Analyzer HMA-TNIRange: 0.05-3 (low), 0.4-10
Mg/L (high), measurement lower limit: 0.01 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface Pure water bucket (including sensor)
7321530K Waste liquid tank (including sensor) 7321540K
Total nickel reagent TZ-HC-TNI-HMA
Sample Preprocessor 8652300
CY-B 8649600
20mL syringe assembly 5461210K 1 year
Syringe piston assembly 7319030K 6 months
Pump pipe 125B724 1 year
O-ring component 8648500
7319040K 1 year PFA hose with a diameter of 2 and a diameter of 3
116D302 1 year sleeve
117B001 1 year Resin hose
1 yearLubricant components 6952210K 6 months
400*300*500mm 9253000
YBX-02 Box body 400 * 300 * 500mm, column 1000mm high, plate thickness 1.0mm 400*300*500mm
YBX-02-FL Box body 400 * 300 * 500mm, column 1000mm high, plate thickness 1.0mm, including 1 power lightning protection (brand: Chint), 1 signal lightning protection (brand: Leixunyuan), 1 2P6A circuit breaker (brand: Chint), and several wiring terminals 400W*300D*500H
YBX-435 Material: 3
04SS, The dashboard is 1.2mm thick and processed with large stainless steel
Five parameter analyzer sc1000 display moduleLXV402.80.00004PH、 Conductivity, dissolved oxygen, turbidity, temperatureSC1000 probe module
8330600 LXV400.99.10382Can connect 6 sensors, 8 channels of 4-20mA outputMODBUS RS485 communication module
YAB021
HC3800PH electrode
Digital conversion module
PH standard solution set
TZ-PH-PH4710
PH standard solution set (4.01,7.00,10.01) -500ml 8331800
Immersion installation components 8326800
MH432G 8331600
The pole is made of PVC material and is 2 meters long Immersion installation components LZX414-3/4'NPT
Material 304, pole length 2 meters HD3600 Conductivity Sensor
Conductivity standard solution PH-1EC1000-500
500ml Immersion installation components
MH432G The pole is made of PVC material and is 2 meters long
Immersion installation components 2947600 LZX414-3/4'NPT
Material 304, pole length 2 meters LDO Dissolved oxygen electrode
9020000SLU Range: 0-20mg/l, with 10m original cable Rod type installation bracket
Ts Line SC suspended solids/turbidity sensor LXV423.80.10101 Range: 0-4000NTU,
1mg/l~50g/l, Accuracy: 5%, with 10m original cable, material: PVC, with automatic cleaning mechanical scraper Suspension optical path calibration solution PH-1TU667-500
500ml Immersion installation bracket LZX414.00.20000
Online multi parameter analyzer MS6100.212 (PH
ORPConductivity, turbidity, residual chlorine, total chlorine)Residual chlorine/total chlorine: 0-5 8332500 mg/L as CL
8331800
Turbidity: 0-20 NTU;
pH:4.00-10.00; 2947600 ORP:-1200 mV~+1200 mV;
Conductivity: 20.0 μ S/cm~2000 μ S/cm; Temperature: 0 ℃~50 ℃ MS6100 pH electrode (including packaging)
MS6100 Conductivity Electrode (including packaging) MS6100 ORP electrode (including packaging) Turbidity standard solution
PH-1TU20-500500mlReagent kit for residual chlorine testing 2556900-CN
Residual chlorine reagentTZ-PH-CL Reagent kit for total chlorine testing 2557000-CN
Total Chlorine ReagentTZ-PH-TCL PH buffer solution reagent kit Can be equipped with domestic standard solution
PH standard solution set TZ-PH-PH4710
PH standard solution set (4.01,7.00,10.01) -500ml 8329100 Redox standard solution, 600mV
25M2A1002-115CN Can be equipped with domestic standard solution ORP standard solution
PH-1ORP200-500
9039700 500ml
Conductivity standard solution, 147 uS/cm LZW9700.99 Can be equipped with domestic standard solution
8760200 Conductivity standard solution, 1413 uS/cm
LZW9710.99 Can be equipped with domestic standard solution Conductivity standard solution
PH-1EC1000-500500mlOnline multi parameter instrument MS6100.112( PH Turbidity, residual chlorine, temperature
Secondary water supply testing MS6100 pH electrode (including packaging)
Reagent kit for residual chlorine testing 2556900-CN
PH buffer solution reagent kit Can be equipped with domestic standard solution
Residual chlorine reagent 2556900-CN
A bottle of 500 A milliliter of buffer solution and indicator solution can guarantee usage for 3 months (calculated based on a ten minute measurement cycle)
Total Chlorine Reagent 2557000-CN
9039700 A bottle of 500
A milliliter of buffer solution and indicator solution can guarantee usage for 3 months (calculated based on a ten minute measurement cycle) S tablCal
Calibration kit 8760200 LZY898
TU5300sc/TU5400sc measurement vial LZY834
Replace one set every year TU5300sc/TU5400sc desiccant box
LZY876 It is recommended to replace one set every year (the replacement interval depends on the environmental humidity, temperature, and sample temperature) KIT
LZY907.97.00002 Single channel maintenance kit
Quantity, for one year's use 9039700 Online chlorophyll analyzer HL4
HL4TABATT 8760200 HL4 host with internal battery compartment
HL4CHLOR RS485 Modbus Communication Module Power cords&cables
CZL010 10 meter underwater cable AC power adapter. 90-264V
AC, 47 to 63 Hz, 12V Chlorophyll standard solution PH-1YLS-500
500ml Multi parameter online analyzer HL7(
Five parameters+chlorophyll+blue-green algae )
HL7TABATT HL7 host with internal battery compartment
HLPHIREF PH reference 2-in-1 probe
HLBGRNA Freshwater blue-green algae
HLCOND Conductivity probe
HLLDO 9039700 Optical dissolved oxygen probe
HLCHLOR 8760200 Chlorophyll probe
HLTURB_SC_BRUSH Turbidity probe and central cleaning brush RS485 Modbus Communication Module
5m underwater cable CZL005 5-meter underwater cable
AC Adapter AC power adapter. 90-264V AC, 47 to 63 Hz, 12V
Chlorophyll standard solutionPH-1YLS-500 500ml Blue-green algae standard solution
TZ-PH-1BGA-5000.03mg/l、0.3mg/l、3mg/l Rhodamine B standard solution HL7 seawater chlorophyll analyzer
HL7TABATT HL7 host with internal battery compartment HLCHLORTII
Titanium chlorophyll probe RS485
Modbus communication module RS485 Modbus communication module
AC Adapter AC power adapter. 90-264V AC, 47 to 63 Hz, 12V
5m underwater cable CZL005
5-meter underwater cable Chlorophyll standard solution PH-1YLS-500
500ml HL7 seawater chlorophyll analyzer (five parameters+blue-green algae+chlorophyll) HL7TABATT
HL7 host with built-in battery compartment and temperature probe HLBGRNAMA
Seawater blue-green algae probe, stainless steel casing HLCHLORTII Titanium chlorophyll probe
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!