Hash online water quality analyzer and accessories consumables | HACH Order Number | DESCRIPTION |
MODBUS module | Running-9013200 | SC200 domestic communication module, default 4-20mA configuration. If there are communication requirements, an additional domestic communication module can be added |
Hash Online PHAnalyzer SC200 | LXV404.99.00102 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
HHACH differential pH electrode PHD ™ | PD1R1 | Range: 0-14PH, -5~+95 ℃, with 4.5m original cable |
Ryton electrode protective cover | 1000F3374-003 | |
PH powder pack (4,7,10) | Running-PH4710 | |
Immersion installation bracket | RNMH434A00B | |
Automatic electrode cleaning device | RN1000A3335-006 | |
Stainless steel circulation pool | RNMH314N4MZ | Material: 304SS |
PH Salt Bridge | SB-P1SV-CN | Sensor material: PEEK |
PH Salt Bridge | SB-R1SV-CN | Sensor material: Ryton |
electrolyte | 25M1A1025-115CN | |
PH electrolyte | PH-10PH-500 | 500ML |
O-ring of PH/ORP | 5H1306 | |
PH standard solution (pH=4500mL) | 2283449 | User defined, it is recommended to calibrate on a monthly basis |
PH standard solution (pH=7500mL) | 2283549 | User defined, it is recommended to calibrate on a monthly basis |
PH standard solution (pH=10500mL) | 2283649 | User defined, it is recommended to calibrate on a monthly basis |
PH standard solution set | Running-PH4710 | PH standard solution set (4.01,7.00,10.01) -500ml |
ORP standard solution (200mV, 500mL) | 25M2A1001-115 | User defined |
ORP standard solution (600mV, 500mL) | 25M2A1002-115CN | User defined |
Hash transmitter Polymetrion9500 | 9500.99.00704 | Output: 4-20mA, Power Supply: 220VAC, Display: LCD |
PH composite electrode | PC1R1A | Range: 0-14PH, 0~105 ℃, with 4.5m original cable |
PH powder pack (4,7,10) | Running-PH4710 | |
Immersion installation bracket | FGMH432G | |
DSC-PH-302sensor | DSCPH030201 | Range: 0-14PHStandard cable length:10rice |
Stainless steel circulation pool | RNMH313N3NZ | |
Hash Online PH Analyzer SC200 | LXV404.99.00102 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
HACHEncapsulated differential pH electrode | 6028P0 | Range: 0-14PH, -5~+95 ℃, with 15m original cable |
LCP electrode protective cover | 60A2F1278 | |
PH powder pack (4,7,10) | Running-PH4710 | |
Immersion installation bracket | RNMH434B | |
Automatic electrode cleaning device | RN1000A3335-003 | |
PVC circulation pool | RNMH376 | |
Hash Online PH Analyzer SC200 | LXV404.99.00102 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD, immersion installation |
pH electrode | EL5600-2-KZ0-(S) Original item number5600-5F(S) |
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃ |
pH electrode | EL5602-0-KZ-(S) Original item number 5602-5F (S) |
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃, drug-resistant electrode |
pH electrode | EL5603-0-KZ-(S) Original item number5603-5F(S) |
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~95 ℃, drug-resistant and high-temperature resistant electrode |
Immersion installation bracket | RNHC703C-2-400A | Pole material PVC, pole length1.5rice |
Hash Online PH Analyzer SC200 | LXV404.99.00102 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD, pressurized, flowing or plug-in installation |
pH electrode | EL5610-2-KZ0-(S) Original item number5610-5F(S) |
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃, pressure type |
pH electrode | EL5612-0-KZ-(S) Original item number5612-5F(S) |
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~70 ℃, resistant pressure electrode |
pH electrode | EL5613-0-KZ-(S) Original item number5613-5F(S) |
Pt1000 customized electrode, cable length: 5m, operating temperature: -5~95 ℃, high temperature and drug resistant pressure electrode |
Flow type sheath | DK-882-PP | Main liquid PP |
, O-ring fluororubber; Flange installation, user specified flange standard, pressure resistance 0.6MPAOnline insertion and removal of protective sleeves(domestic ) |
(Instrument air pressurization is required on site) | DK-SSH-PP |
The main liquid is PP, with an insertion depth of 100-300, threaded, and flange installation DN ≥ 50; Pipeline pressure less than 0.4MPa, temperature below 80 degrees Celsius | Plug in protective sheath (domestic) | DK-880F-PP |
Flange installation, user specified flange standard, pressure resistance of 0.6MPA; Main liquid PP | , O-ring fluororubber | Hash Online ORP Analyzer SC200 |
LXV404.99.00102 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | HACH differential ORP electrode PHDTM |
RD1R5 | Range: -1500~+1500mV, -5~+95 ℃, with 4.5m original cable | |
Ryton electrode protective cover | 1000F3374-003 | ORP standard solution |
ORP200-500 | 500mlImmersion installation bracketR | |
N | MH434A00B | ORP online analyzer Polymetron9500 |
9500.99.00704 | Output: 4-20mA, Power Supply: 220VAC, Display: LCD | ORP composite electrode |
RC1R5N | Range: -2000~+2000mv, with 4.5m original cable | ORP standard solution |
ORP200-500 | 500mlImmersion installation bracketR | |
NMH432GHash Online ORP/T | analyzer | SC200 |
LXV404.99.00102Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDH | ACH | Encapsulated differential ORP electrode |
2028R0 | Range: -2000~+2000mv, -5~+95 ℃, with 7.5m original cable | |
LCP electrode protective cover | 60A2F1278 | ORP standard solution |
ORP200-500 | 500mlImmersion installation bracketR | |
NMH434B | Hash online sludge concentration meter S | olitax ™ sc |
LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDTurbidity of Ts Line SC | / | Suspended solids sensor |
LXV423.80.10101 | Range: 0.001-4000NTU, 0.001mg/L-50g/L, accuracy: 5%, with 10m original cable, material: PVC, with automatic cleaning mechanical scraper | Suspension optical path calibration solution |
TU667-500 | 500mlImmersion installation bracketR | |
N | LZX414.00.20000Stainless steel flow-through installation bracket5738100 | R |
N | Material: 304SS | Self cleaning scraper blade |
LZX050 | Replace once a year, silicone resin, set of 5 pieces | Suspension optical path calibration solution |
TU667-500 | 500ml | 800NTU turbidity standard solution 500ml |
2660549-CN | 5733000 | Two bottles are required for one calibration |
Calibration toolkit | Purchase upon initial order (including one calibration bucket, one 500mL bottle) | 800NTU TablCal standard solution and a probe holder |
Hash online sludge concentration meter Solitax ™ scLXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | Turbidity of Ts Line SC | /Suspended solids |
sensor | LXV423.99.12100 | Range: 0.001-4000NTU, 0.001mg/L-50g/L, accuracy: 5%, with 10m original cable, material: PVC |
Suspension optical path calibration solution | TU667-500500mlImmersion installation bracket | |
R | N | LZX414.00.20000 |
Hash Online Dissolved Oxygen Analyzer SC200LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | LDO | II |
Dissolved oxygen electrode | 9020000SLURange: 0-20mg/l, with 10m original cable, fluorescence method9253000 | |
Rod type installation bracket | RN9253500 | |
Automatic electrode cleaning device | RN9253100 | |
Floating ball installation bracket | 9021100 | |
R | N | Sensor fluorescent cap |
HACH Online Dissolved Oxygen Analyzer SC200 | LXV404.99.00102 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
5500 Clark Dissolved Oxygen Electrode | 5540D0A | |
Range: 0-40mg/l, with 4.5m original cable, polarographic method | Immersion installation bracket | FGMH276R00F |
Membrane head replacement component | 5500A1020-001 | Including a pre installed semi permeable membrane, electrode, electrolyte, and O-ring |
HACH Conductivity Analyzer SC200 | 3422 | LXV404.99.00202 |
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | TriE Conductivity Sensor | 0-200000us/cm, Equipped with 6m cable |
3700E Conductivity Sensor | 3725E2T20G | Range: from 0-200 μ s/cm to 0-2000000 us/cm, with 6m cable |
Conductivity standard solution | EC1000-500500mlPVC circulation pool | |
R | NMH538N3NZImmersion installation bracket | |
R | 9302700 | NMH432GHash Online COD Analyzer CODmaxIIRange:10-5000mg/lAccuracy:10%Output:4-20mACommunication: |
MODBUS/RS485Power supply:220VAC | C | ODreagent |
LCW420 | H | ACH Producer |
COD reagent | TZ-HC-CODHash formula, third-party preparationSample Preprocessor | |
R | N | CY-A |
reagent | LCW420 | |
Tested every 2 hours and calibrated and cleaned every 7 days, it can take about 80 days. I have randomly brought a set | COD reagent | TZ-HC-COD |
One year maintenance of components | YY0000090 | One set per year, I have already brought one set randomly |
Sulfuric acid valve | YY0000288 | One set per year |
Dissolving tank | 8839100 | YY000012224Change every 24 monthsPISTON PUMPevery |
Change once a month | 4555058 | |
For the first timeWhen purchasing a piston pump, it is necessary to equip it with | Fixed parts of piston pump | H |
ACH online COD analyzer SC200 | LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
UVAS Plus SC Organic Matter Sensor (2mm) | LXV418.99.20002 | |
Range: 0-1500m-1SAC, can be converted to COD value, no reagent required, with 10m original cable | Immersion installation bracket | LZY714.99.53520 |
COD standard solution | PH-1COD100-500 | 500ml |
Cleaning brush(2mm optical path) (5 pieces)LZX012 | Replace one set per year and bring one set randomly; | C |
OD analyzer | SC200 | LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDUVAS eco sc organic matter sensorLXV443.80.10002Range:5-1500m-1SAC, can be converted intoCOD |
Value, no reagent required, | belt | |
10m | Original cable | Immersion installation bracket |
LZY714.99.53520 | COD standard solution | PH-1COD100-500 |
500ml | Cleaning brush | LZX148 |
Replace one set per year and bring one set randomly; 1mm optical path length, UVAS and UVAS | Eco universal, 5 pieces | |
Potassium permanganate index analyzer COD-203 | COD203A-2-2C12A11AY0011Range: 0-20mg/L, Reproducibility: ± 1% FS, Output: 4-20mA, Communication: RS485, Power Supply: 220VACPotassium permanganate reagent | |
TZ-HC-CODMN | Sample Preprocessor | |
RN | CY-B | Potassium permanganate reagent |
TZ-HC-CODMNP1 | Pump diaphragm (APN-085LV) | 125A114 |
1 year | P1 | Spring valve (APN-085LV) |
125A1131 year | Air pump muffler | 136A791 |
1 year | 116E032 | Silicon tube |
φ6 xφ 8116C008 | ` | Flexible hose with a diameter of 10 x 14.5 |
7 per yearsolenoid valve | (SV5~10,12~14) | 126A135 |
1 year | solenoid valve | (SV2~4,7) |
126A2821 year | Platinum electrode (0.65m) | EL2059CE |
1 yearreference electrode | #4216 (0.3m) | EL4216AE |
1 year | PFA | Pipe diameter 2 x 3 |
116D30213m/year | activated carbon | 136A075 |
1 yearPFA | 116E023 | Pipe diameter 4 x 6 |
116D3034 months | 116E065 | Uni |
Pipe diameter 5 x 9 | 116E061 | 1 year |
Uni | Pipe diameter 7 x | 15 |
0.2 meters per yearUni Tube | 116E028 | 0.3 meters per year |
Connecting pipe | 7230570K | 1 year |
Uni | Pipe diameter 6 x | 8.5 |
6 months | Sleeve (Z-union 8 PP) | 117B858 |
6 months | Online Oil Analyzer SC200 for WaterLXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | |
FP360 SC Water Oil Sensor | LXV441.99.21102 | Range: 0-500 μ g/l and 0-5000 μ g/l |
(PAH), 0-15mg/l, and 0-150 mg/l (oil); With 10m cable | 8646400 | |
Immersion installation bracket | R | |
N | LZX914.99.11110 | Hash Ammonia Nitrogen Online Analyzer Amtax NA8000 |
NA8000.02 | Range: 0.020mg/L~1000.0mg/L, accuracy: when 0.020mg/L~100.0mg/L: 3%; When 80.00 | |
~1000mg/L: ≤± 10%, power supply: 220VAC, communication: RS485 Modbus, display: color touch screen | 4-20 mA analog signal output I/O module | Ammonia nitrogen chemical reagents (A and additives, B,C) |
LCW937-CN | 8646400 | |
Ammonia nitrogen standard solution cleaning solution set | TZ-PH-NH40550 | |
Blank standard solution+standard solution 1 | (5mg/L)+Standard solution 2 (50mg/L)+Cleaning solution | Ammonia nitrogen preprocessor |
CY-B-03 | Hash Ammonia Nitrogen Online Analyzer Amtax NA8000 | |
NA8000.01 | Range: 0.020mg/L~100.0mg/L, accuracy: 3%, power supply: 220VAC, communication: RS485 | Modbus, Display: Color touch screen |
4-20 mA analog signal output I/O module | Ammonia nitrogen chemical reagents (A and additives, B,C) | |
LCW937-CN | Ammonia nitrogen standard solution cleaning solution set | TZ-PH-NH40550 |
Blank standard solution+standard solution 1 | 8860100 | (5mg/L)+Standard solution 2 (50mg/L)+Cleaning solution |
Ammonia nitrogen preprocessor | CY-B-03 | Chemical reagents (A and additives, B,C) |
LCW937-CN | Change every 2 months, bring a set randomlyStandard solution cleaning solution set | TZ-PH-NH40550 |
Ammonia nitrogen reagent and standard solution kit | TZ-HC-NH4-NA8000 | |
Change every 2 months, bring a set randomly | 6860100 | |
maintenance kit | Replace one set every six months and bring one set randomly | Ammonia nitrogen online analyzer SC200 |
LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCDAISE sc ammonia nitrogen electrodeL | |
XV440.99.10012 | Range: 0-1000mg/l | NH4-N, Accuracy: 5% ± 0.2mg/l of measured value, with 10m cable |
cleaning device | LZY706 | Self cleaning air compressor |
Ammonia nitrogen standard solution | PH-1NH410-500 500ml Handrail installation tool kit |
R |
N | LZX414.00.80000-1 1/4 | Handrail installation tool kit |
RNLZX414.00.80000 | When not equipped with a self-cleaning device, choose | |
Calibration cylinder | LZY6941502 | Replace 3 sets per yearSC1000 transmitterLXV402.80.00004LXV400.99.10172 |
YAB021 | Output: 4-channel 4-20mA, communication: MODBUS/RS485, power supply: 220VAC, touch screen display, can connect 4 sensors | |
Amtax SC ammonia nitrogen analysis module | 6157400-CN | Range: 0.05-20mg/L, accuracy: 3% ± 0.05mg/L |
Sample Preprocessor | FGCY-B | |
SC200 transmitter | LXV404.99.0 | Output: |
2 routes | 4-20mA, Communication: | MODBUS/RS485, Power supply: 220VAC, display: Chinese LCD |
Power module | 2894354 | LQV155.99.00002 |
AMTAX sc reagent, 2500 mL | 2894452-CN | three |
Replace once a month, bring a set randomly | Ammonia nitrogen reagent | TZ-HC-NH4-SC |
1 mg/L NH4-N ammonia nitrogen standard solution, 2000mL | 2894154-CN | three |
Replace once a month, bring a set randomly | 6182500 | Ammonia nitrogen standard solution |
PH-1NH41-2000 | 2000ml | 10 mg/L NH4-N ammonia nitrogen standard solution, 2000mL |
three | Replace once a month, bring a set randomly | Ammonia nitrogen standard solution |
PH-1NH410-2000 | 2000ml | AMTAX sc cleaning solution, 250 mL2894246-CNthreeReplace once a month, bring a set randomlyAmmonia nitrogen cleaning solutionHC-3NH4-250250mlAmtax SC electrolyte and membrane, 11 mLeveryReplace along with the membrane every 2 to 3 months Comes with three bottles of electrolyte and three films, one set is randomly includedAmmonia nitrogen electrode for AMTAX sc analyzer |
LZY069 | Replace once a year | |
Air pump head for AMTAX sc analyzer | LZY181 | Replace once every 1-2 years |
Total Phosphorus Analyzer PHOSPHAX ® Σsigma | LPV341.80.20010 | |
Range:0.01-5.0mg/l | Accuracy: | 2%10Output:24-20mA |
Communication: | MODBUS | RS485 |
, | Power Supply: | 220VAC |
Sample Preprocessor | FGCY-B | 18Reagent (for 0-5mg/L) |
LCW823 | The total phosphorus reagent has a 3-month warranty period after configuration, with a measurement interval of 10 minutes. A set of reagents will be replaced every 3 months. You can also use the program to test every 2 hours, and one set of reagents can be used for one year. Mix according to the required ratio, and store the unmixed separately. Randomly bring a set. | 18Total phosphorus reagent (low) |
TZ-HC-TP-L | Standard solution | 24(2 mg/l) |
LCW824 | Measurement Interval | Minute, replace within a yearSet, bring one set randomlyTotal phosphorus standard solutionPH-1TP2-500500mlOne year maintenance toolkitLZP959Replace one set per year, bring one set randomlyReaction tankLZP856 |
Replace one set every month and bring one set randomly | Mixing motor | |
LZP864 | Replace one set every month and bring one set randomly | Reactor base |
LZP845 | Replace one set every month and bring one set randomly | |
Total Phosphorus Analyzer PHOSPHAX ® Σsigma | ||
LPV341.80.21010 | Range: | 0.01-10.0mg/l |
Accuracy: | 2% | |
Output: | 4-20mA | Communication: |
MODBUS | RS485 | |
Power supply: | 220VAC | 4Sample Preprocessor |
CY-B | Reagent (for 0-10mg/L) | |
LCW893 | The total phosphorus reagent has a 3-month warranty period after configuration, with a measurement interval of 10 minutes. A set of reagents will be replaced every 3 months. You can also use the program to test every 2 hours, and one set of reagents can be used for one year. Mix according to the required ratio, and store the unmixed separately. Randomly bring a set. | 1Total phosphorus reagent (high) |
TZ-HC-TP-H | Other as above | |
Online orthophosphate analyzer SC200 | LXV404.99.00502 | 1Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
Power module | LQV155.99.00002 | PHOSPHAX sc orthophosphate analysis module |
6159600-CN | Range: 0.05-15.0mg/L, accuracy: 2% ± 0.05mg/LSample Preprocessor | CY-B |
Reagent, 2000ml | 2825254-CN | Replace one set every month and bring one set randomly |
Orthophosphate reagent | TZ-HC-P-phosphaxsc | |
Cleaning solution, 1000ml | 2825352-CN | Replace one set annually and bring one set randomly |
Phosphorus cleaning solution, | 1000ml | HC-3P-1000 |
Pump head, used for air pumps | LZY181 | Replace one set annually |
SC200 transmitter | LXV404.99.00502 | |
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | 6860100 | |
Nitratax Plus SC nitrate nitrogen sensor | L | XV417.99.20002 |
Range: 0.1-50mg/l, accuracy: 3%, with 10m original cable | Nitrous nitrogen standard solution | |
PH-1NO320-500 | 500mlImmersion installation bracketLZY714.99.53220 | Cleaning brush (2mm optical path) (5 pieces) |
LZX012 | Replace one set per year, bring one set randomly | Online nitrate nitrogen analyzer SC200 |
LXV404.99.00502Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | NISE sc nitrate nitrogen electrode | LXV440.99.20012 |
Range: 0-1000mg/L | NO3-N, Accuracy: 5% ± 0.2mg/l of measured value, with 10m cable | cleaning device |
LZY706 | Self cleaning air compressor | |
Nitrous nitrogen standard solution | 6860100 | |
PH-1NO320-500 | 500ml | Handrail installation tool kit |
FGLZX414.00.80000-1 | 1/4 | Handrail installation tool kit |
F | GLZX414.00.80000(When not equipped with a self-cleaning device, choose) | |
Calibration cylinder | LZY694 | Replace 3 sets per year |
Online ammonia nitrogen/nitrate nitrogen analyzer | SC200 | LXV404.99.00502 |
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | AN-ISE sc ammonia nitrogen/nitrate nitrogen two in one electrode | LXV440.99.00012 |
Range: 0-1000mg/l | NH4-N、0-1000mg/L NO3-N, Accuracy: 5% ± 0.2mg/l of measured value, with 10m cable | |
cleaning device | LZY706 | |
Self cleaning air compressor | Ammonia nitrogen standard solution | PH-1NH410-500 |
500ml | Nitrous nitrogen standard solution | |
PH-1NO320-500 | 500ml | |
Handrail installation tool kit | R | N |
LZX414.00.80000-1 1/4 | Handrail installation tool kit | |
RNLZX414.00.80000 | (When not equipped with a self-cleaning device, choose) | |
Calibration cylinder | LZY694 | Replace 3 sets per year |
Hash Total Phosphorus and Nitrogen Analyzer NPW-160H | NPW160H-0-11EA00 | Total phosphorus: 0-0.5mg/L; Total nitrogen: 0-20mg/L; Municipal sewage outlets for surface water, tap water, and standard discharge |
Total phosphorus and total nitrogen reagent | TZ-PH-TPTN | |
Sample pretreatment system | CY-B | HACH Total Phosphorus and Nitrogen Analyzer NPW-160H |
NPW160H-0-11GE00 | Total phosphorus: 0~10mg/L; Total nitrogen: 0~50mg/L; Used in the sewage industry | Total phosphorus and total nitrogen reagent |
TZ-PH-TPTN | Sample pretreatment system | CY-B |
Online TP/TN analyzer NPW-160H | NPW160H-0-11HF00 | Total phosphorus: 0-20mg/L (factory setting); Total nitrogen: 0~100mg/L (factory setting); Repeatability: 3%, output: 2-channel 4-20mA, communication: RS485 |
(MODBUS/RTU), Power supply: 220VAC Total phosphorus and total nitrogen reagent |
2976300 | TZ-PH-TPTN2Sample pretreatment systemCY-BTotal phosphorus and total nitrogen reagentTZ-PH-TPTNReplace one set every month (range and standard solution values need to be provided)20mm syringe component5461210KOne per yearpistonOne per yearSyringe kit (set of 5)6804420KHalf a year one set |
Pump hose | 125B724 | |
Half a year one set | PTFE hose (one meter) | 116D002 |
Buy 10 meters, one year | PFA pipe with a diameter of 2 × 3 meters | 116D302 |
Buy 10 meters, one year | Hash ultrasonic sludge interface analyzer | SC200 transmitter+SONATAX sc ultrasonic sensor+elbow type installation hardware |
Output: | road | |
4-20mA | Power supply: | 220VAC |
, Display: Chinese | LCD | Range: |
0.2-12m | Accuracy: | 0.1m |
, with | 10m | cable |
Install fixed accessories | FGLZY428 | |
Sensor Wiper Scraper | LZX328 | |
Replace one set per year, I have already brought one set randomly | HACH Ultrasonic Open Channel Flow Meter SC200 | LXV404.99.00302 |
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | U53S Ultrasonic Flow Sensor | |
U53S033 | Range: 0.25-6m, accuracy: ± 1mm, with 10m cable | Sensor Installation Kit |
3004A0017-001 | AS950 all-weather refrigerated sampler | ASA.CXXX3X41XX |
24/7 refrigerated AS950 sampler, Vinyl | 8572400 | Base, 24 bottles of 1L polyethylene sampling bottles, 230V power supply, USB interface |
AS950 all-weather refrigerated sampler | ASA.CXRX3X41XX | All-weather AS950 sampler, Vinyl |
Base 230V power supply, 24 1L polyethylene sampling bottles, communication: RS485 | 8560400 | AS950 refrigerated sampler |
ASR.CXXX2X41XX | Refrigerated AS950 sampler, Vinyl | Base, 24 bottles of 1L polyethylene sampling bottles, 230V power supply, USB interface |
AS950 refrigerated sampler | 8572400 | ASR.CXRX2X41XX |
Refrigerated AS950 sampler, Vinyl | Base, 24 bottles of 1L polyethylene sampling bottles, 230V power supply, USB interface, MODBUS | AS950 portable sampler |
ASP.CXXXS141XX | 8560400 | Battery Charger |
8753500EU | AS950 portable sampler | ASP.CXRXS141XX |
9184 RS485 | Battery Charger | 8753500EU |
Pump pipe | 4.6m | 4600-15 |
Replace two sets per year | Hash online residual chlorine analyzer SC200 controller | LXV404.99.00502 |
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | CL17sc residual chlorine analyzer | Range: 0-10mg/L; Installation kit with pressure regulator, no reagents |
Residual chlorine reagent | 2556900-CN | Replace one set every month and bring one set randomly; |
CL17sc tube kit | Replace one set per year and bring one set randomly; | Online Total Chlorine Analyzer SC200 Controller |
LXV404.99.00502 | 9160200 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
CL17sc Total Chlorine Analyzer | 9160600 | Range: 0-10mg/L; Installation kit with pressure regulator, no reagents |
Total Chlorine Reagent | 2557000-CN | Replace one set every month and bring one set randomly; |
CL17sc tube kit | Replace one set per year and bring one set randomly; | HACH online residual chlorine analyzer SC200 controller |
LXV404.99.00502 | 9180900 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
SC residual chlorine sensor | 9181400 | LXV432.99.00001 |
Range: 0.005-20ppm (mg/L) HOCl, accuracy: 2% or ± 10ppb | HOCl | Residual chlorine film, 9184sc |
Z09184=A=3500 | Replace the film every six months. This order number includes 4 pieces of film, which can be used for two years | 9184sc electrolyte |
Z09184=A=3600 | Replace every 6 months | pH electrode |
Z368417,00000 | Replace once a year, bring one randomly | Hash online residual chlorine analyzer SC200 controller |
LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | CLF10 sc residual chlorine analyzer panel |
LXV45A.99.13022 | Range: 0-10ppm, accuracy: ± 3% | Membrane replacement component for residual chlorine sensor |
Replace every 6 months | Electrolyte for residual chlorine sensor, 100mL | Replace every 6 months |
Online Total Chlorine Analyzer SC200 Controller | LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
CLT10 sc Total Chlorine Analyzer Panel | LXV45B.99.13022 | Range: 0-10ppm, accuracy: ± 10% |
Membrane replacement component for total chlorine sensor | Replace every 6 months | Electrolyte for total chlorine sensor, 100mL |
1Replace every 6 monthsOnline chlorine dioxide analyzer SC200 controller | 1895000 | LXV404.99.00502 |
Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | 9187sc chlorine dioxide sensor | LXV434.99.00001CN |
Range: 0-2mg/l, accuracy: 5% | 9187sc membrane, 4 pieces | Z09187=A=3500 |
Replace the film every six months. This order number includes 4 pieces of film, which can be used for two years | 8630300 | 9187sc electrolyte, 100ml |
Z09187=A=3600CN | Replace every 6 months | Electrode, replacement, 9187sc |
Z09184=A=1001 | Replace once a year, bring one randomly | Online Ozone Analyzer SC200 Controller |
LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | 9185sc ozone sensor |
LXV433.99.00001 | Range: 0-2ppm, accuracy: ± 3% or ± 10ppb, take the larger value | 9185sc membrane, 4 pieces |
Z09185=A=3500Replace the film every six months. This order number includes 4 pieces of film, which can be used for two years | 9185sc electrolyte, 100ml | Z09185=A=3600 |
Replace every 6 months | HACH online low range turbidity meter (SC200+1720E) | 2978100-CN |
Range: 0.001-100NTU, accuracy: 0 to 40NTU. The range is ± 2% of the reading or ± 0.02NTU, whichever is larger. The range of 40 to 100NTU is ± 5% of the reading. Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD720E | 4503400 | Lamp components |
Replace once a year, bring one randomly; | 4000NTU STABLCA standard solution, 500mL | 246149-CN |
Change one set every year | 20NTU | Stable standard solution |
2660153-CN | Change one set every three months | SC200 transmitter+TU5300sc online laser turbidity meter |
Range: 0-700NTU. Accuracy: When 0-40NTU, it is ± 2% or ± 0.01NTU (whichever is greater) of the reading; At 40-1000NTU, it is ± 10% of the reading. Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | StablCal packaging standard, 10, 20, 600 NTU | |
LZY898-CN | Replace one set every year | |
Replacement of desiccant | LZY876 | |
Replace one set every year | 5705001 | Online measurement of small bottles |
LZY834 | 5410002Replace once every 1-2 years | Fiber scraper brush, self-cleaning module |
LZQ176 | 5740001Suggest replacing it every three months | S |
S7 High Range Turbidity Meter SC200 Controller | LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD |
SS7 turbidity sensor | 5742100 | LPV431.80.00002 |
Range: 0.01-9999.9NTU, Accuracy: 0.01 to 2000NTU Range is ± 5% of reading, 2000 to 9999NTU Range is ± 10% of reading | 5744800 | SS7 |
lamp assembly | Replace once a year, bring one randomly; | 4000NTU STABLCA standard solution, 500mL |
246149-CN | Calibration frequency is determined according to user needs | Sea Turbidity Meter SC200 |
LXV404.99.00502 | Output: 2-channel 4-20mA, power supply: 220VAC, display: Chinese LCD | |
ULTRATURB Seawater SC Sensor | LPV415.99.22002 | |
Range: 0-1000NTU, with 5m cable and automatic cleaning system | Calibration cleaning components (mandatory for calibration)LZV451Fumalazine, 4000NTU, 100ML | |
246142-CN | Filter, used for zero calibration | LZV325 |
Particle counter 2200 PCX | Counting range: 2-750 microns, 8-channel analog signal input and output, flow rate control device | |
Hardness Monitoring and Alarm Instrument SP510 | -CN | |
Monitoring alarm point: 2mg/L, accuracy: ± 10%, alarm output: 1 SPDT relay, power supply: 220VAC | Online fluoride analyzer CA610 | |
-CN | Range: 0.1-10mg/L, Accuracy: ± 10% or ± 0.10mg/L, whichever is greater, Output: 4-20mA, Power Supply: 220VAC, Display: LCD | |
CA610 complete set of reagents: including: reagent 1 (TISAB), standard sample 1, and standard sample 2 | 2816900-CN | Change one set every month |
One year spare parts | Change one set every year, bring one set randomly | sensor assembly |
Including ion selection and pH sensors, sensor heads, and filling fluids | Fluoride ion analyzer FBM-160 | FBM160-1-AA0A0BB0B |
Measurement range: 0~99.9mg/L (factory setting: 0~20), power supply: AC | 90~264V、50/60Hz, No RS-232C interface, wall mounted installation, electrical connection: G1/2, temperature display range: 0~50 degrees | ELCP fluoride ion selective electrode |
ELCP-81-5F | Cable length: 5m | Fluoride ion standard solution (1000mg/L, 500mL) |
PH-1F1000-500 | Ionic strength regulator (PH5-AB, 500mL) | PH-8F-500 |
Immersion installation bracket | R | N |
MH432G | 116E065 | Online hexavalent chromium analyzer HMA-CR6 |
HMA-CR6 | Range: 0.01~2 (low), 0.02~5 | Mg/L (high), measurement lower limit: 0.001 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS |
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface | Pure water bucket (including sensor) | 7321530K |
Waste liquid tank (including sensor) | 7321540K | |
Hexavalent chromium reagent | TZ-HC-CR6-HMA | |
Sample Preprocessor | CY-B | |
20mL syringe assembly | 5461210K | |
1 year | Syringe piston assembly | 7319030K |
6 months | Pump pipe | 125B724 |
6 months | O-ring component | 7319040K |
1 year | Check valve component | 6879770S |
6 months | PFA hose with a diameter of 2 and a diameter of 3 | 116D302 |
1 year | sleeve | 117B001 |
1 year | 116E065 | Resin hose |
1 year | Lubricant components | 6952210K |
6 months | Online total chromium analyzer HMA-TCR | HMA-TCR |
Range: 0.02-2 (low), 0.03-5 | Mg/L (high), measurement lower limit: 0.002 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS | |
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface | Pure water bucket (including sensor) | |
7321530K | Waste liquid tank (including sensor) | |
7321540K | Total chromium reagent | |
TZ-HC-TCR-HMA | Sample Preprocessor | CY-B |
20mL syringe assembly | 5461210K | 1 year |
Syringe piston assembly, 3/6 months | 7319030K | 6 months |
Pump pipe | 125B724 | 1 year |
O-ring component | 7319100K | 1 year |
PFA hose with a diameter of 2 and a diameter of 3 | 116D302 | 1 year |
sleeve | 116E065 | 117B001 |
1 year | Resin hose | 1 year |
Lubricant components | 6952210K | 6 months |
Online total copper analyzer HMA-TCU | HMA-TCU | |
Range: 0.05-3 (low), 0.15-10 | Mg/L (high), measurement lower limit: 0.01 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS | |
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface | Pure water bucket (including sensor) | |
7321530K | Waste liquid tank (including sensor) | |
7321540K | Total copper reagent | TZ-HC-TCU-HMA |
Sample Preprocessor | CY-B | 20mL syringe assembly |
5461210K | 1 year | Syringe piston assembly |
7319030K | 6 months | Pump pipe |
125B724 | 1 year | O-ring component |
7319040K | 1 year | PFA hose with a diameter of 2 and a diameter of 3 |
116D302 | 116E065 | 1 year |
sleeve | 117B001 | 1 year |
Resin hose | 1 year | Lubricant components |
6952210K | 6 months | |
Online Manganese Analyzer HMA-TMN | HMA-TMN | |
Range: 0.1-5 (low), 0.5-20 | Mg/L (high), measurement lower limit: 0.05 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS | |
RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface | Pure water bucket (including sensor) | |
7321530K | Waste liquid tank (including sensor) | 7321540K |
Total Manganese Reagent | TZ-HC-TMN-HMA | Sample Preprocessor |
CY-B | 20mL syringe assembly | 5461210K |
1 year | Syringe piston assembly | 7319030K |
6 months | Pump pipe | 125B724 |
1 year | O-ring component | 7319040K |
1 year | 116E065 | PFA hose with a diameter of 2 and a diameter of 3 |
116D302 | 1 year | sleeve |
117B001 | 1 year | Resin hose |
1 year | Lubricant components | 6952210K |
6 months | HMA-TNI Total Nickel Analyzer | HMA-TNIRange: 0.05-3 (low), 0.4-10 |
Mg/L (high), measurement lower limit: 0.01 ppm, accuracy: ± 3% F.S (according to relevant national verification regulations), output: 4-20mA, communication: MODBUS | RTU/RS485, Power supply: 220VAC, display: Chinese color LCD touch surface | Pure water bucket (including sensor) |
7321530K | Waste liquid tank (including sensor) | 7321540K |
Total nickel reagent | TZ-HC-TNI-HMA | |
Sample Preprocessor | 8652300 | |
CY-B | 8649600 | |
20mL syringe assembly | 5461210K | 1 year |
Syringe piston assembly | 7319030K | 6 months |
Pump pipe | 125B724 | 1 year |
O-ring component | 8648500 | |
7319040K | 1 year | PFA hose with a diameter of 2 and a diameter of 3 |
116D302 | 1 year | sleeve |
117B001 | 1 year | Resin hose |
1 yearLubricant components | 6952210K | 6 months |
400*300*500mm | 9253000 | |
YBX-02 | Box body 400 * 300 * 500mm, column 1000mm high, plate thickness 1.0mm | 400*300*500mm |
YBX-02-FL | Box body 400 * 300 * 500mm, column 1000mm high, plate thickness 1.0mm, including 1 power lightning protection (brand: Chint), 1 signal lightning protection (brand: Leixunyuan), 1 2P6A circuit breaker (brand: Chint), and several wiring terminals | 400W*300D*500H |
YBX-435 | Material: 3 | |
04SS, The dashboard is 1.2mm thick and processed with large stainless steel Five parameter analyzer sc1000 display moduleLXV402.80.00004PH、 Conductivity, dissolved oxygen, turbidity, temperatureSC1000 probe module |
8330600 | LXV400.99.10382Can connect 6 sensors, 8 channels of 4-20mA outputMODBUS RS485 communication module YAB021 HC3800PH electrode Digital conversion module PH standard solution set TZ-PH-PH4710 |
PH standard solution set (4.01,7.00,10.01) -500ml | 8331800 | |
Immersion installation components | 8326800 | |
MH432G | 8331600 | |
The pole is made of PVC material and is 2 meters long | Immersion installation components | LZX414-3/4'NPT |
Material 304, pole length 2 meters | HD3600 Conductivity Sensor | |
Conductivity standard solution | PH-1EC1000-500 | |
500ml | Immersion installation components | |
MH432G | The pole is made of PVC material and is 2 meters long | |
Immersion installation components | 2947600 | LZX414-3/4'NPT |
Material 304, pole length 2 meters | LDO | Dissolved oxygen electrode |
9020000SLU | Range: 0-20mg/l, with 10m original cable | Rod type installation bracket |
Ts Line SC suspended solids/turbidity sensor | LXV423.80.10101 | Range: 0-4000NTU, |
1mg/l~50g/l, Accuracy: 5%, with 10m original cable, material: PVC, with automatic cleaning mechanical scraper | Suspension optical path calibration solution | PH-1TU667-500 |
500ml | Immersion installation bracket | LZX414.00.20000 |
Online multi parameter analyzer MS6100.212 | (PH | 、 |
ORPConductivity, turbidity, residual chlorine, total chlorine)Residual chlorine/total chlorine: 0-5 | 8332500 | mg/L as CL |
₂ | 8331800 | |
; | Turbidity: 0-20 NTU; | |
pH:4.00-10.00; | 2947600 | ORP:-1200 mV~+1200 mV; |
Conductivity: 20.0 μ S/cm~2000 μ S/cm; | Temperature: 0 ℃~50 ℃ | MS6100 pH electrode (including packaging) |
MS6100 Conductivity Electrode (including packaging) | MS6100 ORP electrode (including packaging) | Turbidity standard solution |
PH-1TU20-500500mlReagent kit for residual chlorine testing | 2556900-CN | |
Residual chlorine reagentTZ-PH-CL | Reagent kit for total chlorine testing | 2557000-CN |
Total Chlorine ReagentTZ-PH-TCL | PH buffer solution reagent kit | Can be equipped with domestic standard solution |
PH standard solution set | TZ-PH-PH4710 | |
PH standard solution set (4.01,7.00,10.01) -500ml | 8329100 | Redox standard solution, 600mV |
25M2A1002-115CN | Can be equipped with domestic standard solution | ORP standard solution |
PH-1ORP200-500 | ||
9039700 | 500ml | |
Conductivity standard solution, 147 uS/cm | LZW9700.99 | Can be equipped with domestic standard solution |
8760200 | Conductivity standard solution, 1413 uS/cm | |
LZW9710.99 | Can be equipped with domestic standard solution | Conductivity standard solution |
PH-1EC1000-500500mlOnline multi parameter instrument MS6100.112( | PH | Turbidity, residual chlorine, temperature |
Secondary water supply testing | MS6100 pH electrode (including packaging) | |
Reagent kit for residual chlorine testing | 2556900-CN | |
PH buffer solution reagent kit | Can be equipped with domestic standard solution | |
Residual chlorine reagent | 2556900-CN | |
A bottle of 500 | A milliliter of buffer solution and indicator solution can guarantee usage for 3 months (calculated based on a ten minute measurement cycle) | |
Total Chlorine Reagent | 2557000-CN | |
9039700 | A bottle of 500 | |
A milliliter of buffer solution and indicator solution can guarantee usage for 3 months (calculated based on a ten minute measurement cycle) | S | tablCal |
Calibration kit | 8760200 | LZY898 |
TU5300sc/TU5400sc measurement | vial | LZY834 |
Replace one set every year | TU5300sc/TU5400sc desiccant | box |
LZY876 | It is recommended to replace one set every year (the replacement interval depends on the environmental humidity, temperature, and sample temperature) | KIT |
LZY907.97.00002 | Single channel maintenance kit | |
Quantity, for one year's use | 9039700 | Online chlorophyll analyzer HL4 |
HL4TABATT | 8760200 | HL4 host with internal battery compartment |
HL4CHLOR | RS485 Modbus Communication Module | Power cords&cables |
CZL010 | 10 meter underwater cable | AC power adapter. 90-264V |
AC, 47 to 63 Hz, 12V | Chlorophyll standard solution | PH-1YLS-500 |
500ml | Multi parameter online analyzer HL7( | |
Five parameters+chlorophyll+blue-green algae | ) | |
HL7TABATT | HL7 host with internal battery compartment | |
HLPHIREF | PH reference 2-in-1 probe | |
HLBGRNA | Freshwater blue-green algae | |
HLCOND | Conductivity probe | |
HLLDO | 9039700 | Optical dissolved oxygen probe |
HLCHLOR | 8760200 | Chlorophyll probe |
HLTURB_SC_BRUSH | Turbidity probe and central cleaning brush | RS485 Modbus Communication Module |
5m underwater cable | CZL005 | 5-meter underwater cable |
AC Adapter | AC power adapter. 90-264V | AC, 47 to 63 Hz, 12V |
Chlorophyll standard solutionPH-1YLS-500 | 500ml | Blue-green algae standard solution |
TZ-PH-1BGA-5000.03mg/l、0.3mg/l、3mg/l | Rhodamine B standard solution | HL7 seawater chlorophyll analyzer |
HL7TABATT | HL7 host with internal battery compartment | HLCHLORTII |
Titanium chlorophyll probe | RS485 | |
Modbus communication module | RS485 | Modbus communication module |
AC Adapter | AC power adapter. 90-264V | AC, 47 to 63 Hz, 12V |
5m underwater cable | CZL005 | |
5-meter underwater cable | Chlorophyll standard solution | PH-1YLS-500 |
500ml | HL7 seawater chlorophyll analyzer (five parameters+blue-green algae+chlorophyll) | HL7TABATT |
HL7 host with built-in battery compartment and temperature probe | HLBGRNAMA | |
Seawater blue-green algae probe, stainless steel casing | HLCHLORTII | Titanium chlorophyll probe |
Online inquiry