HYDC double shell leak free liquid chlorine magnetic pump
The HYDC leak free double shell magnetic submersible pump is a pump type designed for applications where full sealing is required to prevent leakage o
Product details

1、 HYDC Liquid Chlorine Magnetic Pump General

Model Meaning HYDC50-32
H Enterprise code
Y Submersible pump
DC chemical pump
50 Imported caliber 80mm
32 Lift 32
name: HYDC Leak Free Double Shell Magnetic Submersible Pump/Leak Free Liquid Chlorine Magnetic Pump/Double Shell Liquid Chlorine Magnetic Pump/Liquid Chlorine Special Pump
Transport medium: Liquid chlorine
Applicable industries: Chlor alkali, chemical industry, flammable, explosive, volatile, high-risk industries
Product features: Double isolation sleeve protection, secondary sealing alarm, no leakage
Structural form: API685 standard, bucket bag type, pump and motor direct coupling connection
Caliber: 25~125mm
Traffic: 1.8-400m3/h
Lift: 15-125m
Speed: 1450/2900r/min
Working temperature: -20~+200℃
Pressure level: 1.6-5.0Mpa
Power: 1.5-110kw
Material Science:

304, 304L, 316, 316L HC276


2、 Overview of HYDC Liquid Chlorine Magnetic Pump

HYDC The leak free double shell magnetic submersible pump is a type of submersible pump designed to prevent leakage of the medium during transportation and requires full enclosure. The submersible part that comes into contact with the liquid is made of stainless steel, and the main body of the pump is completely placed in the liquid. It adopts a static seal design and does not have traditional mechanical seals. The medium can be completely isolated from the external air, truly achieving no leakage. It is particularly suitable for flammable, explosive, toxic, and high-risk media. It has the advantages of wide corrosion resistance, high efficiency, safe and reliable shaft connection structure, and easy disassembly. It can pump without filling the liquid. Due to the axial force and radial force generated by the pump operation being supported by rolling bearings and sliding bearings respectively, it runs quietly and noiselessly. A high-tech and sustainable product that combines environmental protection and energy conservation, with strong corrosion resistance Good wear resistance, high mechanical strength, food grade, reasonable design, compact structure, reliable performance, easy use and maintenance, high efficiency, and energy saving.

Not the product you want? Click here to return to the previous page

3、 Characteristics of HYDC liquid chlorine magnetic pump

1.HYDCThe leak free double shell magnetic submersible pump is a new type of industrial pump developed and designed by our company based on HG/T2730-2012 and API685-2000, featuring a fully sealed, leak free, and pollution-free double shell structure. It has fewer sealing points, a compact structure, strong versatility, vertical installation, and more convenient maintenance;

2. The materials of the overcurrent components such as the pump body, inner rotor, pump cover, impeller, isolation sleeve, and pump shaft can be 304, 316, 316L, 904, TA2, HC276, etc;
3. The pump body and pump cover are designed with CFD computer fluid dynamics hydraulic components for module design and precision casting, which have high anti cavitation ability, precise size, smooth flow channel, and ensure the corrosion resistance and pressure resistance of the pump;
4. The impeller adopts CFD computer fluid dynamics to design hydraulic components for module design and precision casting, ensuring reliable torque transmission. Its closed structure, optimized flow channel design, high efficiency, and low NPSHR value ensure the stability of pump flow and head;
5. The isolation sleeve is made of materials such as 316L, TA2, HC276, and designed with a low vortex isolation sleeve. The isolation sleeve is located in a sinusoidal alternating magnetic field, inducing eddy currents on a cross-section perpendicular to the magnetic field lines and converting them into heat. The use of high resistivity and high-strength materials such as 316L, TA2, HC276, etc. has a significant effect on reducing eddy currents, with high resistance to rupture pressure and high safety factor. At the same time, the pump chamber is completely isolated from the outside, making the pump chamber completely sealed and achieving no leakage during transportation.
6. The dynamic ring, shaft sleeve, and sliding bearing are made of high wear-resistant and temperature resistant materials such as crystalline silicon carbide and tungsten carbide, which have high strength, wear resistance, good flexibility, and strong corrosion resistance, effectively ensuring the service life of the pump. The rolling bearings are imported NSK or SKF grease lubricated maintenance free bearings;
7. The magnetic block is made of samarium cobalt 2:17, with a magnetic energy product of 28 megaGauss Ultras and a maximum temperature tolerance of 350 ℃, which can greatly avoid demagnetization and ensure a theoretical service life of up to 20 years for the magnetic material;
8. The pump axial force self balancing structure utilizes hydraulic principles to automatically balance axial force through fluid pressure difference. The thrust plate of the rolling bearing only bears unbalanced axial force at the moment of starting and stopping, and can achieve almost zero axial force at the operating point, greatly improving the stability of the whole machine operation;
9. The magnetic pump adopts a double sliding bearing structure, which runs more smoothly, ensures smooth medium circulation, and provides excellent lubrication effect for the sliding bearings; The elastic gasket structure in the shaft sleeve and sliding bearing extends the service life of the bearing, reduces pump vibration, and avoids sliding bearing expansion and cracking caused by high temperature conditions;
10. No leakage, all sealing points adopt closed static sealing, driven by magnetic couplings, no need for nitrogen sealing, safe, economical and efficient, completely solving medium leakage;


4、 Working range of HYDC liquid chlorine magnetic pump


5、 HYDC application scope

Widely used in the transportation of volatile, flammable, explosive, toxic, harmful and other high-risk media in production processes such as petroleum, chemical, coalification, alkali production, smelting, rare earth, pesticides, dyes, pharmaceuticals, scientific research institutions, and national defense industries.


6、 Attention points for HYDC liquid chlorine magnetic pump

1.Media with a specific gravity greater than 1.3mg/cm3 should be specified when ordering;

2.Prohibit air freight transfer;

3.Do not transport media containing particles or crystals.


7、 Schematic diagram of HYDC liquid chlorine magnetic pump structure



8、 Performance parameter table of HYDC magnetic pump


model rotational speed
r/min
internet traffic
m3/h
lift
m
efficiency
npsh
m
Import X Export
mm
Motor Power
kw
25HYDC-20 2900 1.5 22 28 2.5 25×20 2.2
2 20 34.5 2.5
3.2 18.5 36 3
25HYDC-32 2900 1.5 34.3 24 2.5 25×20 3
2 32 32 2.5
3.2 29.6 33 3
25HYDC-50 2900 1.5 52.5 28 2.5 25×20 5.5
2 50 32 2.5
3.2 48 30 3
25HYDC-80 2900 1.5 82 26 2.5 25×20 11
2 80 30 2.5
3.2 78.5 28 3
32HYDC-20 2900 2 22 40 2.5 32×20 2.2
3.2 20 44 2.5
5.5 18.5 42 3
32HYDC-32 2900 2 34.3 40 2.5 32×20 3
3.2 32 44 2.5
5.5 29.6 42 3
32HYDC-50 2900 2 52.5 32 2.5 32×20 5.5
3.2 50 36 2.5
5.5 48 34 3
32HYDC-80 2900 2 82 26 2.5 32×20 11
3.2 80 30 2.5
5.5 78.5 28 3
40HYDC-20 2900 4.4 22 41 2.5 40×25 2.2
6.3 20 46 2.5
8.3 18.5 43 3
40HYDC-32 2900 4.4 34.3 35 2.5 40×25 3
6.3 32 40 2.5
8.3 29.6 38 3
40HYDC-50 2900 4.4 52.5 26 2.5 40×25 7.5
6.3 50 33 2.5
8.3 48 32 3
40HYDC-80 2900 4.4 82 24 2.5 40×25 11
6.3 80 28 2.5
8.3 78.5 28 3
50HYDC-20 2900 7.5 22 43 2 50×32 3
12.5 20 51 2
15 18.5 49 2.5
50HYDC-32 2900 7.5 34.3 33 2 50×32 4
12.5 32 44.5 2
15 29.6 46 2.5
50HYDC-50 2900 7.5 52.5 28 2 50×32 7.5
12.5 50 37 2
15 48 40.5 2.5
50HYDC-80 2900 7.5 82 23 2 50×32 15
12.5 80 32 2
15 78.5 36.5 2.5
65HYDC-20 2900 15 21.8 37 2 65×50 4
25 20 57 2
30 18.5 60 2.5
65HYDC-32 2900 15 35 44 2 65×50 5.5
25 32 53 2
30 30 57 2.5
65HYDC-50 2900 15 53 41 2 65×40 11
25 50 50 2
30 47 53.5 2.5
65HYDC-80 2900 15 82 34 2 65×40 18.5
25 80 46 2
30 78 50 2.5
65HYDC-125 2900 15 127 28 2.5 65×40 30
25 125 39 2.5
30 123 48.5 3
80HYDC-20 2900 30 22.5 53 3 80×65 7.5
50 20 57 3
60 18 47 3.5
80HYDC-32 2900 30 36 52 2.5 80×65 11
50 32 62 2.5
60 29 60 3
80HYDC-50 2900 30 53 53 2.5 80×50 15
50 50 60 2.5
60 47 58 3
80HYDC-80 2900 30 84 44 2.5 80×50 30
50 80 55 2.5
60 75 57 3
80HYDC-125 2900 30 128 39 2.5 80×50 45
50 125 48 2.5
60 123 47.5 3
100HYDC-20 2900 60 24 59 4 100×80 11
100 20 67 4.5
120 16.5 57 5
100HYDC-32 2900 60 36 56 3.5 100×80 15
100 32 67 4
120 28 68 5
100HYDC-50 2900 60 54 57 3 100×65 30
100 50 67 3.6
120 47 66 4.8
100HYDC-80 2900 60 87 52 3.5 100×65 45
100 80 63 3.8
120 74.5 62 4.8
100HYDC-125 2900 60 133 48 3 100×65 75
100 125 57 3.6
120 118 59 4.2
125HYDC-20 2900 120 23 63 4.5 125×100 22
200 20 72 4.5
240 18 65 5
125HYDC-32 2900 120 35 57 3.8 125×100 30
200 32 70 4.2
240 28 69 5
125HYDC-50 1450 120 55 57 2.5 150×125 45
100 50 70 2.5
240 45 67 3
150HYDC-20 1450 120 132.5 56 4 125×100 22
200 20 65 4.5
240 120 58 5
150HYDC-32 1450 120 52 51 2.5 125×100 30
200 32 57 2.5
240 48.5 53 3
150HYDC-50 1450 120 53 56 2.5 150×125 45
200 50 65 2.8
240 46 58 3.5
200HYDC-20 1450 240 21.5 68 3.5 200×150 37
400 20 74 4.3
460 17.5 70 5
200HYDC-32 1450 240 37 62 3 200×150 75
400 32 74 3.5
460 28.5 72 4
200HYDC-50 1450 240 55 62 3 200×150 110
400 50 73 3.8
460 45 70 4.5
250HYDC-20 1450 600 22 75 4.1 250×200 75
800 20 78 5
960 16 77 6
250HYDC-32 1450 600 34 73 4.8 250×200 90
800 32 75 5.5
960 28 75 6.4
250HYDC-50 1450 600 54.5 55 3.5 250×200 160
800 50 68 4.3
960 39 70 5
300HYDC-32 1450 1550 35 58 3.6 300×250 220
1400 32 74 4.5
1300 26 65 5.4
300HYDC-50 1450 1550 55 65 4.1 300×250 315
1400 50 75 5
1300 42.5 73 6

Installation diagram:



——————————————————————————————————————————————————————————————————————————

Product shooting:








Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!