1、 HYDC Liquid Chlorine Magnetic Pump General
Model Meaning | HYDC50-32 |
H | Enterprise code |
Y | Submersible pump |
DC | chemical pump |
50 | Imported caliber 80mm |
32 | Lift 32 |
name: | HYDC Leak Free Double Shell Magnetic Submersible Pump/Leak Free Liquid Chlorine Magnetic Pump/Double Shell Liquid Chlorine Magnetic Pump/Liquid Chlorine Special Pump |
Transport medium: | Liquid chlorine |
Applicable industries: | Chlor alkali, chemical industry, flammable, explosive, volatile, high-risk industries |
Product features: | Double isolation sleeve protection, secondary sealing alarm, no leakage |
Structural form: | API685 standard, bucket bag type, pump and motor direct coupling connection |
Caliber: | 25~125mm |
Traffic: | 1.8-400m3/h |
Lift: | 15-125m |
Speed: | 1450/2900r/min |
Working temperature: | -20~+200℃ |
Pressure level: | 1.6-5.0Mpa |
Power: | 1.5-110kw |
Material Science: |
304, 304L, 316, 316L HC276 |
2、 Overview of HYDC Liquid Chlorine Magnetic Pump
HYDC The leak free double shell magnetic submersible pump is a type of submersible pump designed to prevent leakage of the medium during transportation and requires full enclosure. The submersible part that comes into contact with the liquid is made of stainless steel, and the main body of the pump is completely placed in the liquid. It adopts a static seal design and does not have traditional mechanical seals. The medium can be completely isolated from the external air, truly achieving no leakage. It is particularly suitable for flammable, explosive, toxic, and high-risk media. It has the advantages of wide corrosion resistance, high efficiency, safe and reliable shaft connection structure, and easy disassembly. It can pump without filling the liquid. Due to the axial force and radial force generated by the pump operation being supported by rolling bearings and sliding bearings respectively, it runs quietly and noiselessly. A high-tech and sustainable product that combines environmental protection and energy conservation, with strong corrosion resistance Good wear resistance, high mechanical strength, food grade, reasonable design, compact structure, reliable performance, easy use and maintenance, high efficiency, and energy saving.
Not the product you want? Click here to return to the previous page】
3、 Characteristics of HYDC liquid chlorine magnetic pump
1.HYDCThe leak free double shell magnetic submersible pump is a new type of industrial pump developed and designed by our company based on HG/T2730-2012 and API685-2000, featuring a fully sealed, leak free, and pollution-free double shell structure. It has fewer sealing points, a compact structure, strong versatility, vertical installation, and more convenient maintenance;
2. The materials of the overcurrent components such as the pump body, inner rotor, pump cover, impeller, isolation sleeve, and pump shaft can be 304, 316, 316L, 904, TA2, HC276, etc;
3. The pump body and pump cover are designed with CFD computer fluid dynamics hydraulic components for module design and precision casting, which have high anti cavitation ability, precise size, smooth flow channel, and ensure the corrosion resistance and pressure resistance of the pump;
4. The impeller adopts CFD computer fluid dynamics to design hydraulic components for module design and precision casting, ensuring reliable torque transmission. Its closed structure, optimized flow channel design, high efficiency, and low NPSHR value ensure the stability of pump flow and head;
5. The isolation sleeve is made of materials such as 316L, TA2, HC276, and designed with a low vortex isolation sleeve. The isolation sleeve is located in a sinusoidal alternating magnetic field, inducing eddy currents on a cross-section perpendicular to the magnetic field lines and converting them into heat. The use of high resistivity and high-strength materials such as 316L, TA2, HC276, etc. has a significant effect on reducing eddy currents, with high resistance to rupture pressure and high safety factor. At the same time, the pump chamber is completely isolated from the outside, making the pump chamber completely sealed and achieving no leakage during transportation.
6. The dynamic ring, shaft sleeve, and sliding bearing are made of high wear-resistant and temperature resistant materials such as crystalline silicon carbide and tungsten carbide, which have high strength, wear resistance, good flexibility, and strong corrosion resistance, effectively ensuring the service life of the pump. The rolling bearings are imported NSK or SKF grease lubricated maintenance free bearings;
7. The magnetic block is made of samarium cobalt 2:17, with a magnetic energy product of 28 megaGauss Ultras and a maximum temperature tolerance of 350 ℃, which can greatly avoid demagnetization and ensure a theoretical service life of up to 20 years for the magnetic material;
8. The pump axial force self balancing structure utilizes hydraulic principles to automatically balance axial force through fluid pressure difference. The thrust plate of the rolling bearing only bears unbalanced axial force at the moment of starting and stopping, and can achieve almost zero axial force at the operating point, greatly improving the stability of the whole machine operation;
9. The magnetic pump adopts a double sliding bearing structure, which runs more smoothly, ensures smooth medium circulation, and provides excellent lubrication effect for the sliding bearings; The elastic gasket structure in the shaft sleeve and sliding bearing extends the service life of the bearing, reduces pump vibration, and avoids sliding bearing expansion and cracking caused by high temperature conditions;
10. No leakage, all sealing points adopt closed static sealing, driven by magnetic couplings, no need for nitrogen sealing, safe, economical and efficient, completely solving medium leakage;
4、 Working range of HYDC liquid chlorine magnetic pump
5、 HYDC application scope
Widely used in the transportation of volatile, flammable, explosive, toxic, harmful and other high-risk media in production processes such as petroleum, chemical, coalification, alkali production, smelting, rare earth, pesticides, dyes, pharmaceuticals, scientific research institutions, and national defense industries.
6、 Attention points for HYDC liquid chlorine magnetic pump
1.Media with a specific gravity greater than 1.3mg/cm3 should be specified when ordering;
2.Prohibit air freight transfer;
3.Do not transport media containing particles or crystals.
7、 Schematic diagram of HYDC liquid chlorine magnetic pump structure
8、 Performance parameter table of HYDC magnetic pump
model |
rotational speed r/min |
internet traffic m3/h |
lift m |
efficiency % |
npsh m |
Import X Export mm |
Motor Power kw |
25HYDC-20 | 2900 | 1.5 | 22 | 28 | 2.5 | 25×20 | 2.2 |
2 | 20 | 34.5 | 2.5 | ||||
3.2 | 18.5 | 36 | 3 | ||||
25HYDC-32 | 2900 | 1.5 | 34.3 | 24 | 2.5 | 25×20 | 3 |
2 | 32 | 32 | 2.5 | ||||
3.2 | 29.6 | 33 | 3 | ||||
25HYDC-50 | 2900 | 1.5 | 52.5 | 28 | 2.5 | 25×20 | 5.5 |
2 | 50 | 32 | 2.5 | ||||
3.2 | 48 | 30 | 3 | ||||
25HYDC-80 | 2900 | 1.5 | 82 | 26 | 2.5 | 25×20 | 11 |
2 | 80 | 30 | 2.5 | ||||
3.2 | 78.5 | 28 | 3 | ||||
32HYDC-20 | 2900 | 2 | 22 | 40 | 2.5 | 32×20 | 2.2 |
3.2 | 20 | 44 | 2.5 | ||||
5.5 | 18.5 | 42 | 3 | ||||
32HYDC-32 | 2900 | 2 | 34.3 | 40 | 2.5 | 32×20 | 3 |
3.2 | 32 | 44 | 2.5 | ||||
5.5 | 29.6 | 42 | 3 | ||||
32HYDC-50 | 2900 | 2 | 52.5 | 32 | 2.5 | 32×20 | 5.5 |
3.2 | 50 | 36 | 2.5 | ||||
5.5 | 48 | 34 | 3 | ||||
32HYDC-80 | 2900 | 2 | 82 | 26 | 2.5 | 32×20 | 11 |
3.2 | 80 | 30 | 2.5 | ||||
5.5 | 78.5 | 28 | 3 | ||||
40HYDC-20 | 2900 | 4.4 | 22 | 41 | 2.5 | 40×25 | 2.2 |
6.3 | 20 | 46 | 2.5 | ||||
8.3 | 18.5 | 43 | 3 | ||||
40HYDC-32 | 2900 | 4.4 | 34.3 | 35 | 2.5 | 40×25 | 3 |
6.3 | 32 | 40 | 2.5 | ||||
8.3 | 29.6 | 38 | 3 | ||||
40HYDC-50 | 2900 | 4.4 | 52.5 | 26 | 2.5 | 40×25 | 7.5 |
6.3 | 50 | 33 | 2.5 | ||||
8.3 | 48 | 32 | 3 | ||||
40HYDC-80 | 2900 | 4.4 | 82 | 24 | 2.5 | 40×25 | 11 |
6.3 | 80 | 28 | 2.5 | ||||
8.3 | 78.5 | 28 | 3 | ||||
50HYDC-20 | 2900 | 7.5 | 22 | 43 | 2 | 50×32 | 3 |
12.5 | 20 | 51 | 2 | ||||
15 | 18.5 | 49 | 2.5 | ||||
50HYDC-32 | 2900 | 7.5 | 34.3 | 33 | 2 | 50×32 | 4 |
12.5 | 32 | 44.5 | 2 | ||||
15 | 29.6 | 46 | 2.5 | ||||
50HYDC-50 | 2900 | 7.5 | 52.5 | 28 | 2 | 50×32 | 7.5 |
12.5 | 50 | 37 | 2 | ||||
15 | 48 | 40.5 | 2.5 | ||||
50HYDC-80 | 2900 | 7.5 | 82 | 23 | 2 | 50×32 | 15 |
12.5 | 80 | 32 | 2 | ||||
15 | 78.5 | 36.5 | 2.5 | ||||
65HYDC-20 | 2900 | 15 | 21.8 | 37 | 2 | 65×50 | 4 |
25 | 20 | 57 | 2 | ||||
30 | 18.5 | 60 | 2.5 | ||||
65HYDC-32 | 2900 | 15 | 35 | 44 | 2 | 65×50 | 5.5 |
25 | 32 | 53 | 2 | ||||
30 | 30 | 57 | 2.5 | ||||
65HYDC-50 | 2900 | 15 | 53 | 41 | 2 | 65×40 | 11 |
25 | 50 | 50 | 2 | ||||
30 | 47 | 53.5 | 2.5 | ||||
65HYDC-80 | 2900 | 15 | 82 | 34 | 2 | 65×40 | 18.5 |
25 | 80 | 46 | 2 | ||||
30 | 78 | 50 | 2.5 | ||||
65HYDC-125 | 2900 | 15 | 127 | 28 | 2.5 | 65×40 | 30 |
25 | 125 | 39 | 2.5 | ||||
30 | 123 | 48.5 | 3 | ||||
80HYDC-20 | 2900 | 30 | 22.5 | 53 | 3 | 80×65 | 7.5 |
50 | 20 | 57 | 3 | ||||
60 | 18 | 47 | 3.5 | ||||
80HYDC-32 | 2900 | 30 | 36 | 52 | 2.5 | 80×65 | 11 |
50 | 32 | 62 | 2.5 | ||||
60 | 29 | 60 | 3 | ||||
80HYDC-50 | 2900 | 30 | 53 | 53 | 2.5 | 80×50 | 15 |
50 | 50 | 60 | 2.5 | ||||
60 | 47 | 58 | 3 | ||||
80HYDC-80 | 2900 | 30 | 84 | 44 | 2.5 | 80×50 | 30 |
50 | 80 | 55 | 2.5 | ||||
60 | 75 | 57 | 3 | ||||
80HYDC-125 | 2900 | 30 | 128 | 39 | 2.5 | 80×50 | 45 |
50 | 125 | 48 | 2.5 | ||||
60 | 123 | 47.5 | 3 | ||||
100HYDC-20 | 2900 | 60 | 24 | 59 | 4 | 100×80 | 11 |
100 | 20 | 67 | 4.5 | ||||
120 | 16.5 | 57 | 5 | ||||
100HYDC-32 | 2900 | 60 | 36 | 56 | 3.5 | 100×80 | 15 |
100 | 32 | 67 | 4 | ||||
120 | 28 | 68 | 5 | ||||
100HYDC-50 | 2900 | 60 | 54 | 57 | 3 | 100×65 | 30 |
100 | 50 | 67 | 3.6 | ||||
120 | 47 | 66 | 4.8 | ||||
100HYDC-80 | 2900 | 60 | 87 | 52 | 3.5 | 100×65 | 45 |
100 | 80 | 63 | 3.8 | ||||
120 | 74.5 | 62 | 4.8 | ||||
100HYDC-125 | 2900 | 60 | 133 | 48 | 3 | 100×65 | 75 |
100 | 125 | 57 | 3.6 | ||||
120 | 118 | 59 | 4.2 | ||||
125HYDC-20 | 2900 | 120 | 23 | 63 | 4.5 | 125×100 | 22 |
200 | 20 | 72 | 4.5 | ||||
240 | 18 | 65 | 5 | ||||
125HYDC-32 | 2900 | 120 | 35 | 57 | 3.8 | 125×100 | 30 |
200 | 32 | 70 | 4.2 | ||||
240 | 28 | 69 | 5 | ||||
125HYDC-50 | 1450 | 120 | 55 | 57 | 2.5 | 150×125 | 45 |
100 | 50 | 70 | 2.5 | ||||
240 | 45 | 67 | 3 | ||||
150HYDC-20 | 1450 | 120 | 132.5 | 56 | 4 | 125×100 | 22 |
200 | 20 | 65 | 4.5 | ||||
240 | 120 | 58 | 5 | ||||
150HYDC-32 | 1450 | 120 | 52 | 51 | 2.5 | 125×100 | 30 |
200 | 32 | 57 | 2.5 | ||||
240 | 48.5 | 53 | 3 | ||||
150HYDC-50 | 1450 | 120 | 53 | 56 | 2.5 | 150×125 | 45 |
200 | 50 | 65 | 2.8 | ||||
240 | 46 | 58 | 3.5 | ||||
200HYDC-20 | 1450 | 240 | 21.5 | 68 | 3.5 | 200×150 | 37 |
400 | 20 | 74 | 4.3 | ||||
460 | 17.5 | 70 | 5 | ||||
200HYDC-32 | 1450 | 240 | 37 | 62 | 3 | 200×150 | 75 |
400 | 32 | 74 | 3.5 | ||||
460 | 28.5 | 72 | 4 | ||||
200HYDC-50 | 1450 | 240 | 55 | 62 | 3 | 200×150 | 110 |
400 | 50 | 73 | 3.8 | ||||
460 | 45 | 70 | 4.5 | ||||
250HYDC-20 | 1450 | 600 | 22 | 75 | 4.1 | 250×200 | 75 |
800 | 20 | 78 | 5 | ||||
960 | 16 | 77 | 6 | ||||
250HYDC-32 | 1450 | 600 | 34 | 73 | 4.8 | 250×200 | 90 |
800 | 32 | 75 | 5.5 | ||||
960 | 28 | 75 | 6.4 | ||||
250HYDC-50 | 1450 | 600 | 54.5 | 55 | 3.5 | 250×200 | 160 |
800 | 50 | 68 | 4.3 | ||||
960 | 39 | 70 | 5 | ||||
300HYDC-32 | 1450 | 1550 | 35 | 58 | 3.6 | 300×250 | 220 |
1400 | 32 | 74 | 4.5 | ||||
1300 | 26 | 65 | 5.4 | ||||
300HYDC-50 | 1450 | 1550 | 55 | 65 | 4.1 | 300×250 | 315 |
1400 | 50 | 75 | 5 | ||||
1300 | 42.5 | 73 | 6 |
Installation diagram:
——————————————————————————————————————————————————————————————————————————
Product shooting: