HT250D Headspace Automatic Sample Injector
HT250D Headspace Automatic Sample Injector: The new automatic sample injector supports dual inlet injection in both liquid and headspace injection mod
Product details

HT250D Headspace Automatic Sample Injectorcharacteristic:

As an automatic sampler manufacturer in the industry, hta continuously launches new products to meet users' requirements for chromatographic analysis accuracy and automation. The HT250D is based on the HT200H high-sensitivity headspace automatic sampler and adds the HT300A liquid sampler module, so the instrument has two injection methods simultaneously. The redesigned components are all user replaceable, making the switching between headspace injection and liquid injection very simple, without the need to move the automatic sampler or recalibrate the injection port. The new automatic sampler supports dual injection ports in both liquid and headspace injection modes, with the function of a dual tower automatic sampler, and IQ/OQ/PQ support services.

HT250D Headspace Automatic Sample InjectorSpecifications:

Liquid injection mode

Number of samples

110 (2 ml sample bottle)

Injection needle capacity

You can choose 1ul, 10ul, 25ul, 50ul or 100ul (standard configuration is 10ul)

Injection volume

Zui can reach as little as 0.1ul

Air Volume

Zui can reach as little as 0.1ul

Extraction speed

Can be set from 0.1 to 100 ul/sec

Injection speed

Can be set from 0.1 to 100 ul/sec

Needle washing program

Can be set to repeat up to 15 times, providing four types of solvents for cleaning

Injection mode

The repeated extraction method can effectively remove bubbles and can be set to repeat up to 15 times

Viscosity delay

Can be set to 1 to 60 seconds

Internal standard injection

1. The minimum injection volume can reach 0.1ul

2. The minimum air volume can reach 0.1ul

3. The air gap between the sample or internal standard can be set

Procedural method

10 methods that can be set for sample extraction, injection, and cleaning, with a minimum volume of 0.1ul, and 15 steps that can be set

Headspace injection mode

Number of samples

40 bottles (20ml headspace bottle, 10ml headspace bottle is optional)

Injection needle capacity

2.5ml

injection volume

Zui can reach as little as 0.01ml

Injection speed

Can be set from 0.1 to 100ml/min

Injection balance delay

Can be set from 0 to 60 seconds

Injection frequency

Can be repeated up to 15 times

Injection needle temperature

Can be set from 40 to 150 ℃

Sample heating box

1. Zui can heat up to 6 sample bottles simultaneously

2. The temperature can be set from 40 to 150 ℃

3. The heating time can be set from 0 to 23 hours and 59 minutes

4. The oscillation time can be set from 0 to 99 minutes

purge gas

Use inert gas (nitrogen or helium)

Injection mode

Repeated extraction method, and can be set to repeat up to 15 times

Dual injection mode

Only applicable to certain models (with front and rear injection ports), such as Shimadzu GC-17/2010, Varian3400/3800

Efficient injection: Two types of samples can be automatically injected into two injection ports in sequence for efficient analysis.

Repeated injection: The same sample can be automatically injected into two injection ports in sequence for confirmation analysis experiments.

compatibility

Seamless compatibility with various atmospheric phase manufacturers (agilent, Perkin Elmer, Varian, Shimadzu, Thermo, etc.), sample tray can be freely changed to the left or right.

software

Ht comsoft ah or clarity chromatography workstation

Related product links:

HT300A high-efficiency gas-phase liquid automatic sampler
HT200H high-sensitivity gas phase headspace automatic sampler
HT250D gas phase liquid/headspace automatic sampler
HPLC dual channel high-throughput automatic sampler

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!