Shanghai Jiahui Instrument Co., Ltd
Home>Products>HI122 laboratory high-precision pH/ORP/temperature measuring instrument [built-in printing]
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1590219666713818101591
  • Address
    209, Building 1, Kaige Technology Park, No. 2653 Hunan Road, Pudong New Area, Shanghai
Contact Now
HI122 laboratory high-precision pH/ORP/temperature measuring instrument [built-in printing]
HI122 laboratory high-precision pH/ORP/temperature measuring instrument with built-in printing. Can measure pH value, ORP, Multiple parameters such as
Product details

HI122 laboratory high-precision pH/ORP/temperature measuring instrument with built-in printing. Can measure pH value, ORP, Multiple parameters such as temperature. High precision analysis, easy operation, unique direct printing function, can conveniently store and print measurement results.

Humanized design, convenient operation, large screen display
• Can simultaneously measure multiple parameters to meet various laboratory requirements
Up to five points of automatic calibration ensure high measurement accuracy
PH resolution can be selected, with automatic temperature compensation function
• Large capacity storage function, GLP laboratory standard, can view calibration data
Equipped with RS232 data interface, it can be connected to a computer for data output analysis
Built in printer that can directly print measurement results.

model

HI 122

range pH value

-2.00 to 16.00 pH; -2.000 to 16.000 pH

ORP

±999.9 mV;±2000 mV

temperature

-20.0 to 120.0°C

resolution pH value

0.01 pH; 0.001 pH

ORP

0.1 mV;1 mV

temperature

0.1 °C

accuracy pH value

±0.01pH;±0.002pH

ORP

±0.2 mV;±0.5 mV;±1 mV

temperature

± 0.4°C

PH calibration

Automatic 1-point or 2-point calibration, with 7 built-in calibration points (pH 1.68/4.01/6.86/7.01/9.18/10.01/12.45)

temperature compensation

Automatic or manual temperature compensation, -20.0 to 120.0 ° C

Relative potential offset

±2000 mV

Calibration verification

Electrode status, response time, and calibration solution status

electrode type

Using BNC acidity electrode interface and HI7662 temperature probe

Data Storage

Manually store 50 data and automatically store 1000 measurement data

data interface

RS232 data interface, connected to a computer (data software and cable need to be purchased)

printer

Built in printer, 44mm printing paper

Input impedance

10 12Ohm

Power supply mode

12 Vdc power adapter

Usage environment

0 to 50°C (32 to 122°F);RH max 95%

Dimension

280 x 203 x 84mm; 1.9 kg