Principle and Structure of HFS Target Water Flow Switch
When the flow rate exceeds the set value, the fluid pushes the blade and drives the micro switch at the top through the mechanical device inside the water flow switch. Its single pole double throw switch contact (SPDT) can make one circuit conductive while cutting off the other circuit This water flow switch is usually used in places that require interlocking or "cut-off" protection. The number of blades can be adjusted and the length of the blades can be adjusted to meet the needs of different pipe diameters and flow rates.

HFS target water flow switch
Overview of HFS Target Water Flow Switch
The water flow switch has SPDT output, excellent performance, high precision and reliability. Can be installed in water pipes or liquid pipelines that have no corrosive effect on copper. When the liquid flow rate reaches a certain rate, one circuit may close and the other circuit may open without reaching the rated point.
The water flow switch is only used for liquid media above 0 ℃, and can also be used for high salt liquids, but not classified as hazardous liquids.
The water flow switch can be installed outdoors and can be installed horizontally or vertically in pipelines.
The water flow switch is only used for operational control. It is necessary to strengthen the sense of responsibility and limit control of installation personnel, as well as the alarm monitoring system, to prevent the occurrence of control failures.
Note: The water flow switch cannot be hit by water. If a quick closing valve is installed downstream of the water flow switch, a throttle must be used.
Application of HFS Target Water Flow Switch
Water flow switches are mainly used in water treatment systems, central air conditioning, water-cooled units and other fields. They are suitable for water, ethylene glycol and any other liquid that has no corrosive effect on brass, phosphor copper and has no impact on sealing performance.
| Technical Parameter | ||
|---|---|---|
| degrees of protection provided by enclosure | IP54 or IP67 | |
| Output format: | Micro switch SPDT output | |
| Wiring method: | Terminal wiring | |
| lifetime | Contact life: | 100000 times |
| Bellows lifespan: | 100000 times | |
| medium | Temperature range: | -10~105℃ |
| Media type: | Air, water, and oil | |
| Maximum pressure: | 16 bar or 40 bar | |
| texture of material: | The shell is made of brass or stainless steel, and the baffle is made of stainless steel material | |
| electrical | Electrical parameters: | AC 250V |
| power | ||
| 2.5A | ||
| 15A | ||
| Insulation resistance: | Over 100w.DC500VM | |
| Micro switch parameters: | 15A(max.)、250VAC/DC) | |
| Flow control range | ||||||
|---|---|---|---|---|---|---|
| category | Flow range | LPA(GPM) | ||||
| pipe diameter | Flow direction sheet | minimum | maximum | |||
| the metric system | English system | Off-Fiow | Off-Fiow | |||
| DN25 | 1 | 1P | 8(2.0) | 41(11.0) | ||
| DN32 | 1-1/4 | 13(3.4) | 68(18.0) | |||
| DN40 | 1-1/2 | 20(5.3) | 94(25.0) | |||
| DN50 | 2 | 2P | 17(4.5) | 105(28.0) | ||
| DN65 | 2-1/2 | 34(9.0) | 188(50.0) | |||
| DN80 | 3 | 30(8.0) | 275(73.0) | |||
| DN100 | 4 | 3P | 64(17.0) | 360(95.0) | ||
| DN125 | 5 | 113(30.0) | 652(172) | |||
| DN150 | 6 | 172(45.0) | 975(258) | |||
| Note: This table contains experimental data and requires consideration of 10/margin. The actual operation department will adjust it based on the actual flow rate | ||||||

Flow control range diagram of HFS target water flow switch

Dimensional drawing of HFS target water flow switch
| Selection code | ||||
|---|---|---|---|---|
| HFS- | 1 | 2 | 3 | 4 |
| Applicable pipe diameter | ||||
| 1 | 10 | G3/8 '' -19 internal thread (suitable for diameter DN10) | ||
| 15 | G1/2 "-14 tooth internal pipe thread (suitable for pipe diameter DN15) | |||
| 20 | G3/4 "-14 tooth internal pipe thread (suitable for pipe diameter DN20) | |||
| 25 | G1 "-11 tooth internal pipe thread (applicable for pipe diameter DN25) | |||
| A | G1 "-11 tooth external pipe thread (DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150) | |||
| 2 | Material Description | |||
| 1 | POM engineering plastic valve body | |||
| 2 | Original copper valve body | |||
| 3 | Stainless steel 304 valve body | |||
| 3 | Factory set parameters | |||
| 1 | Cut off min 0.5N (N) and connect Max 1.5N (N) | |||
| 4 | Material of protective cover | |||
| A | Fire grade carbonated polymer protective shell | |||
| 5 | OEM customization | |||
| / | Regular shipment without customized content | |||
| A | Nameless light plate customized product | |||
| B | Designated nameplate, designated trademark product | |||