Shanghai Yidong Electric Appliance Co., Ltd
Home>Products>Gitec GK500 Mini Inverter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    021-59109252
  • Address
    3-4/F, Building E, 1055 Kesheng Road, Malu Town, Jiading District, Shanghai
Contact Now
Gitec GK500 Mini Inverter
Mini frequency converters are specially designed for low-power applications, with small size and simple operation. They also have open-loop vector con
Product details

Naming rules


Naming rules for product models


20180621142434_68883

Product nameplate description
20180621142434_70234

Product series description

voltage
grade
Type power level
(kW)
output current
(A)
Input current (A) electrical machinery
(kW)
brake
unit
200V GK500-2T0.4B 0.4 2.6 5.5 0.4 standard
built-in
GK500-2T0.75B 0.75 4.5 9.2 0.75
GK500-2T1.5B 1.5 7.5 14.5 1.5
GK500-2T2.2B 2.2 9.5 23 2.2
400V GK500-4T0.75B 0.75 2.5 3.4 0.75
GK500-4T1.5B 1.5 3.8 5.6 1.5
GK500-4T2.2B 2.2 5.5 8.1 2.2
GK500-4T3.7B 3.7 9 13.5 3.7

Note: The 2T model is compatible with both three-phase 200V input and single-phase 200V input.


Technical Parameter


product specification

power input rated voltage 3-phase 380VAC~480VAC
3-phase 200VAC~240VAC, single-phase 200VAC~240VAC
input current Refer to Section 2.3
frequency 50Hz/60Hz, Range of fluctuation ± 5%
Allowable voltage range Voltage fluctuates continuously by ± 10%, with brief fluctuations ranging from -15% to 10%;
Voltage imbalance rate<3%, distortion rate meets the requirements of IEC61800-2
power output Standard applicable motor (kW) Refer to Section 2.3
Rated current (A) Refer to Section 2.3
Output voltage (V) 3-phase: 0 to rated input voltage, with an error of less than ± 3%
Output frequency (Hz) 0~600.00Hz, Unit 0.01Hz
Overload capacity 150% for 1 minute; 180% 10 seconds; 200% 0.5 seconds
Operational control characteristics control mode V/f control
No PG vector control 1
No PG vector control 2
speed range 1: 100 (V/f control, no PG vector control 1)
1: 200 (without PG vector control 2)
Speed control accuracy ± 0.5% (V/f control)
± 0.2% (without PG vector control 1,2)
Speed fluctuation ± 0.3% (without PG vector control 1,2)
Torque response <10ms (without PG vector control 1,2)
starting torque 0.5Hz: 180% (V/f control, no PG vector control 1)
0.25Hz: 180% (without PG vector control 2)
basic function START FREQUENCY 0.00~600.00Hz
Acceleration and deceleration time 0.00~60000s
Carrier Frequency 0.7kHz~12kHz
Frequency setting method Number setting+operation panel ∧/∨
Digital setting+terminal UP/DOWN
Control panel potentiometer
Communication settings
Simulation Setting (AI)
Start mode Starting from the starting frequency
DC brake first and then start
Shutdown mode Slow down and stop the machine
Free parking
Deceleration and shutdown+DC braking
Energy consumption braking capability Braking unit operating voltage: 400V level: 650V~750V;
200V level: 350-400V
Usage time: 0.0~100.0s
DC braking capability DC braking starting frequency: 0.00~600.00Hz
DC braking current: 0.0~100.0% DC braking time: 0.0~30.00s
Input terminal Four switch input terminals
An analog input terminal with optional voltage and current inputs
Output terminal A switch output terminal
A set of relay output terminals
An analog output terminal with optional voltage and current outputs, capable of outputting physical quantities such as set frequency and output frequency
Featured Features Flexible function code display implicit, various main and auxiliary settings and switching, multiple acceleration and deceleration curve selection, analog automatic correction, up to 8-speed operation, swing frequency control operation, fixed length control, counting function, three sets of fault records, overexcitation braking, overvoltage stall, undervoltage stall, power failure restart, jumping frequency, frequency binding, four stage acceleration and deceleration time free switching, motor temperature protection, process PID control, simple PLC, parameter identification, weak magnetic control, high-precision torque limitation
Protection function Refer to Chapter 7 "Fault Diagnosis and Exception Handling"
environment Place of use Indoor, not exposed to direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, dripping or salt, etc
altitude 0-2000 meters
Reduce the rated output current by 1% for every 100 meters increase when using over 1000 meters
ambient temperature -10℃~50℃
humidity 5% to 95%, condensation is not allowed
vibrate Less than 5.9 m/s2(0.6g)
Storage temperature -40℃~70℃
other efficiency At rated power
3.7kW and below: ≥ 93%
Installation method Wall Mount
protection grade IP20
Cooling method Forced air cooling





Product appearance and installation dimensions

Type Appearance and installation dimensions (mm)
W H D W1 H1 Installation hole d
GK500-4T0.75B 75 166 168 59 154 4.5
GK500-4T1.5B
GK500-4T2.2B 85 188 172 69 175 4.5
GK500-4T3.7B
GK500-2S0.4B 75 166 168 59 154 4.5
GK500-2S0.75B
GK500-2S1.5B 85 188 172 69 175 4.5
GK500-2S2.2B



Function Description of Control Terminal


category Terminal symbol Terminal name technical specifications
Analog input +10V analog input
reference voltage
10.3V ±3%
maximumtransportOutput current 25mA
When connecting an external potentiometer, a potentiometer with a resistance greater than 4k Ω should be selected
GND analog ground Internal and COM connection
AI analog input 0-20mA: Input impedance of 500 Ω,maximumInput current 25mA
0-10V: Input impedance 100k Ω,maximumInput voltage 12.5V
By toggling the switch, AI can switch between 0-20mA and 0-10V analog inputs, with the default voltage input at the factory
Analog output AO analog output 0-20mA: Impedance requirement of 200 Ω -500 Ω
0-10V: Impedance requirement ≥ 10k Ω
By toggling the switch, AO can switch between 0-20mA and 0-10V analog output, with default voltage output at the factory
GND analog ground Internal and COM isolation
Switching input +24V +24V 24V ± 10%, internally connected to GND
maximumLoad 200mA
COM +24V ground Internally connected to GND
X1~X4 Switching input
Terminals 1-4
Input specifications: 24VDC, 5mA
Frequency range: 0-200Hz
Voltage range: 10V~30V
Switching Output Y Open collector output Voltage range: 0-24V
Current range: 0-50mA
Relay RA/RB/RC Control board relay output RA-RB: normally closed; RA-RC: normally open
Contact capacity: 250VAC/3A, 30VDC/3A
Terminal 485
interface
485+ 485 differential signal positive Speed: 800/9600/19200/38400/57600/115200bps
485− 485 differential signal negative Maximum distance of 500 meters (using standard Ethernet cable)
GND 485 communication shielding grounding Internal and COM connection
Operation panel interface CN2 Grounding of operation panel The longest communication distance when connecting the operation panel is 15 meters
Using standard Ethernet cables



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!