Jiedao IslandGC1690Introduction to series gas chromatographs:
Product name: Gas chromatograph
model:GC1690series
Manufacturer: Jiedao
GC1690The series of high-performance gas chromatographs are laboratory analytical instruments independently developed, produced, and marketed by Jiedao Company. They can be optionally combined with hydrogen flame ionization according to usage needs(FID)TheThermal conductivity(TCD)Two types of detectors that can detect boiling points399.CPerform constant, trace, and even trace analysis on the following organic, inorganic, and gas substances. Widely used in fields such as petroleum, chemical, fertilizer, pharmaceuticals, electricity, food, fermentation, environmental protection, and metallurgy.GC1690The series of high-performance gas chromatographs is a generation of gas chromatographs developed by Jiedao Company using advanced technology and integrating the advantages of domestic gas chromatographs. Flexible selection of hydrogen flame ionization according to usage needs(FID)The Thermal conductivity(TCD)Flame luminosity(FPD)Nitrogen and phosphorus(NPD)
Jiedao IslandGC1690Main features of series gas chromatographs
The new model adopts back pressure valve diversion/splitless
column oven
Taking into account the thermal radiation generated by the heating of the gasification chamber or detector, the high-performance column temperature box is designed as an upright structure to achieve maximum operating temperature420℃,Temperature range+7℃~420℃,5Step program temperature rise, automatic rear door opening, can be set420Temperature for use at heights within ℃, fixed450℃ independent protection circuit with dual protection structure.
injector
1.Fill the column with samples
2.shunt/splitless
3.Large caliber capillary tubeWBCinjection
4.Filling column vaporization injection
5.Six way valve air inlet style
Jiedao IslandGC1690Main technical parameters and indicators of series gas chromatographs:
column oven
Temperature range:room temperature+7℃~420℃
Temp Accuracy:be better than±0.1℃
Internal volume:240×160×360
Program order:5steps
heating rate:0.1~39.9℃/minAny setting
heating up time:0~665min(increment1min)
*1、 Over temperature protection: When the actual temperature of each hot zone exceeds the set maximum value, the over temperature protection device works, automatically cutting off the power supply of each heating zone of the instrument, and sounding an alarm to avoid accidents.
*2Overcurrent protection: WhenTCDWhen the detector is working, if the current is set too high orTCDWhen the resistance suddenly increases, the overcurrent protection device works and automatically cuts offTCDBridge current, alarm and display simultaneouslyOVER TCDTo protect the tungsten wire from burning out (if the user starts it without gas supply due to operational errors)TCDThe device can also automatically cut off the power to protect the tungsten wire. Amplification circuits can also be added to increase sensitivity.
*3、 Crash protection: When the instrument is in operation, it can automatically cut off the power and sound an alarm in case of short circuit or open circuit of the thermistor in each heating zone, grounding of the heating wire, or system crash of the microcomputer operating system, to avoid accidents caused by continuing to work. The above three protection functions can make your analysis work safer and more reassuring.
Six major temperature controls
GC1690The gas chromatograph is capable of six temperature control channels, among whichAUX1Control external heating device, column temperature andAUX1Equipped with a five stage program for heating up.
Pneumatic control
The gas path controller adopts an external type, with capillary gas path box and gas combustion assisting gas path box placed independently. The airflow ratio adjustment is intuitive and easy to understand, and the control is flexible. Moreover, once a certain gas path problem occurs, it can be immediately switched, which has no impact on the operation of the host and is easy to maintain.
Low noise
Each fan blade inside the host is molded in one go using molds, with good symmetry to avoid imbalance and noise during operation.
Flexible configuration
The capillary injector is independent and can be configured with dual capillary injectors and dual amplification plates according to user requirements, allowing for the simultaneous installation of two capillary columns; Two filling columns can also be installed simultaneously; It is also possible to install both a packed column and a capillary column simultaneously; It can also be flexibly increased on this basisTCD、FPD、NPD、ECDDetector to meet different analysis requirements; One instrument can be equipped with up to three types of injectors and three types of detectors.
Beautiful appearance
Using a vertical column box, it has a beautiful and elegant appearance, and occupies a small area, suitable for use in small laboratory spaces.
belt“*'Indicates that the technology is domestic *.
detector |
Sensitivity or sensitivity |
drift |
noise |
linear range |
Hydrogen Flame (FID) |
Mt≤1×10-11g/s |
≤1×10-12(A/30min) |
≤2×10-13A |
≥106 |
Thermal conductivity (TCD) |
S≥2000mV. m1/mg |
≤0.1(mV/30min) |
≤0.01mV |
≥106 |
Flame (FPD) |
P≤2×11-12g/s S≤5×10-11g/s |
≤4 ×10-11(A/30min) |
≤2×10-11A |
P ≥103 S ≥102 |
Nitrogen (NPD) |
N≤1×10-12g/s P≤5×10-11g/s |
≤2 ×10-12(A/30min) |
≤4 ×10-13A |
≥103 |
Electron Capture (ECD) |
≤2×10-13g/ml |
≤50(uV/30min) |
≤20uV |
≥103 |
Inventory name |
Specification and model |
unit |
Reference selling price |
gas chromatograph |
GC1690F(twoPIP+twoFID) |
tower |
30800.00 |
gas chromatograph |
GC1690F(J)(Single)FID+SPL) |
tower |
30800.00 |
gas chromatograph |
GC1690F(S)(Single)PIP+oneFID) |
tower |
25800.00 |
gas chromatograph |
GC1690T(S)(Single)PIP+TCD) |
tower |
25800.00 |
gas chromatograph |
GC1690T(twoPIP+TCD) |
tower |
30800.00 |
gas chromatograph |
GC1690T(Double)PIP+TCD+Gas injection) |
tower |
32000.00 |
gas chromatograph |
GC1690J(twoFID+twoPIP+SPL) |
tower |
34800.00 |
gas chromatograph |
GC1690J(S)(twoFID+onePIP+SPL) |
tower |
33800.00 |
gas chromatograph |
GC1690A(twoFID+TCD+twoPIP+SPL) |
tower |
38800.00 |
gas chromatograph |
GC1690B(twoFID+twoPIP+TCD) |
tower |
34800.00 |
gas chromatograph |
GC1690B(FID+twoPIP+TCD+Dual gas injection+reformer) |
tower |
38400.00 |
gas chromatograph |
GC1690C(twoFID+twoPIP+SPL+Double enlarged board) |
tower |
37800.00 |
gas chromatograph |
GC1690G(twoFID+twoPIP+Double enlarged board) |
tower |
33800.00 |
gas chromatograph |
GC1690Q(twoFID+twoSPL+Single amplification board) |
tower |
36800.00 |
gas chromatograph |
GC1690N(twoFID+twoSPL+Double enlarged board) |
tower |
39800.00 |
gas chromatograph |
GC1691F(twoPIP+twoFID) |
tower |
39921.90 |
gas chromatograph |
GC1650J(constant temperature+oneFID+SPL) |
tower |
27800.00 |
gas chromatograph |
GC1650F(constant temperature+onePIP+oneFID) |
tower |
23800.00 |
gas chromatograph |
GC1650T(constant temperature+onePIP+TCD) |
tower |
23800.00 |
gas chromatograph |
GC1650TF(constant temperature+twoPIP+TCD+oneFID) |
tower |
27800.00 |
gas chromatograph |
GC1650E(constant temperature+onePIP+ECD) |
tower |
33600.00 |
gas chromatograph |
GC1650E(J)(constant temperature+oneSPL+ECD) |
tower |
36600.00 |
gas chromatograph |
GC1650P(constant temperature+onePIP+FPD) |
tower |
37800.00 |
gas chromatograph |
GC1650P(J)(constant temperature+oneSPL+FPD) |
tower |
40800.00 |
gas chromatograph |
GC1650S(constant temperature+onePIP+NPD) |
tower |
39600.00 |
gas chromatograph |
GC1650S(J)(constant temperature+oneSPL+NPD) |
tower |
42600.00 |
gas chromatograph |
GC1690E(Cheng Sheng+onePIP+ECD) |
tower |
35600.00 |
gas chromatograph |
GC1690E(J)(Cheng Sheng+oneSPL+ECD) |
tower |
38600.00 |
gas chromatograph |
GC1690P(Cheng Sheng+onePIP+FPD) |
tower |
39800.00 |
gas chromatograph |
GC1690P(J)(Cheng Sheng+oneSPL+FPD) |
tower |
42800.00 |
gas chromatograph |
GC1690S(Cheng Sheng+onePIP+NPD) |
tower |
41600.00 |
gas chromatograph |
GC1690S(J)(Cheng Sheng+oneSPL+NPD) |
tower |
44600.00 |
gas chromatograph |
GC1690D(Cheng Sheng+twoPIP+FID+FPD) |
tower |
47800.00 |
gas chromatograph |
GC1690D(J)(Cheng Sheng+twoPIP+SPL+FID+FPD) |
tower |
51800.00 |
gas chromatograph |
GC1690DJJ(Cheng Sheng+twoSPL+FID+FPD) |
tower |
54800.00 |
gas chromatograph |
GC1690K(Cheng Sheng+twoPIP+FID+ECD) |
tower |
43600.00 |
gas chromatograph |
GC1690K(J)(Cheng Sheng+twoPIP+SPL+FID+ECD) |
tower |
47600.00 |
gas chromatograph |
GC1690KJJ(Cheng Sheng+twoSPL+FID+ECD) |
tower |
50600.00 |
gas chromatograph |
GC1690R(Cheng Sheng+twoPIP+FID+NPD) |
tower |
45400.00 |
gas chromatograph |
GC1690R(J)(Cheng Sheng+twoPIP+SPL+FID+NPD) |
tower |
49400.00 |
gas chromatograph |
GC1690RJJ(Cheng Sheng+twoSPL+FID+NPD) |
tower |
52400.00 |
gas chromatograph |
GC1690ENJJ(Cheng Sheng+twoSPL+ECD+NPD) |
tower |
65400.00 |
gas chromatograph |
GC1690EPJJ(Cheng Sheng+twoSPL+ECD+FPD) |
tower |
63600.00 |
gas chromatograph |
GC1690L-1(Cheng Sheng+twoPIP+SPL+FID+FPD+ECD) |
tower |
65600.00 |
gas chromatograph |
GC1690L-2(Cheng Sheng+twoPIP+SPL+FID+NPD+ECD) |
tower |
67400.00 |
gas chromatograph |
GC1690L-3(Cheng Sheng+onePIP+twoSPL+FID+ECD+FPD) |
tower |
68600.00 |
gas chromatograph |
GC1690L-4(Cheng Sheng+onePIP+twoSPL+FID+ECD+NPD) |
tower |
70400.00 |
gas chromatograph |
GC1690L-5(Cheng Sheng+3*SPL+FID+ECD+FPD) |
tower |
71600.00 |
gas chromatograph |
GC1690L-6(Cheng Sheng+3*SPL+FID+ECD+NPD) |
tower |
73400.00 |
ECd |
GC1690-ECD |
tower |
13800.00 |
flame photometric detector |
GC1690-FPD |
tower |
18000.00 |
Nitrogen and phosphorus detector |
GC1690-NPD |
tower |
19800.00 |
thermal conductivity detector |
GC1690-TCD |
tower |
5000.00 |
GC-FID |
GC1690-FID(twoFID) |
tower |
5000.00 |