Fluke51II thermometer from the United States
Fluke51II thermometer from the United States, single input digital thermometer, includes: anti-collision protective cover, one 80PK-1 bead probe therm
Product details
brand Fluke

Product features of Fluke51II thermometer from the United States

  • The minimum, maximum, and average values with relative time stamps provide time references for major events
  • The electronic compensation function can compensate for thermocouple errors and maximize overall accuracy
  • Measure J, K, T, and E type thermocouples
  • The sturdy Fluke 50 II series new contact type handheld thermometer features fast response capability and laboratory accuracy (0.05%+0.3 ° C).
  • The reading unit can be º C, º F, or Kelvin (K)
  • Waterproof and dust-proof shell, protective sheath that absorbs impact force
  • Humanized front panel, easy to set up and operate
  • Sleep mode, extending battery life - typical value is 1000 hours
  • Replace the battery without breaking the calibration lead seal
  • By using the optional ToolPak accessory, the thermometer can be hung on any metal object (using a magnet) or on a pipe (using nylon straps and buckles), freeing up both hands
  • 3-year warranty

Technical parameters of Fluke51II thermometer from the United States:

Temperature accuracy
Above -100 ° C: J. K, T, E, and N types: ± [0.05%+0.3 ° C]*
R and S types: ± [0.05%+0.4 ° C]*
Below -100 ° C: J. K, E, and N types: ± [0.20%+0.3 ° C]*
T-type: ± [0.50%+0.3 ° C]
Temperature range J-type: -210 ° C to 1200 ° C
K-type: -200 ° C to 1372 ° C
T-type: -250 ° C to 400 ° C
E-type: -150 ° C to 1000 ° C
N-type: -200 ° C to 1300 ° C*
R and S types: 0 ° C to 1767 ° C*
Temperature scale ITS-90
Standards NIST-175
display resolution 0.1 °C, 0.1 K < 1000

1°C, 1 K >=1000

pour Only Fluke 53 II and 54 II thermometers can measure N, R, and S thermocouples

Environmental technical indicators

operation temperature -10 ° C to 50 ° C
storage temperature -40 ° C to 60 ° C
Relative humidity (non condensing) 0% to 90%; 0 ° C to 35 ° C
0% to 70%; 0 ° C to 50 ° C

Safety technical indicators

Overvoltage protection category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
authentication CE, CSA, T Ü V (pending approval)

Mechanical and General Technical Indicators

size 173 mm L x 86 mm W x 38 mm
weight 400 g
battery 3 AA model batteries, with a typical battery life of 1000 hours