Fixed wireless acetylene detector
Fixed wireless acetylene detector with integrated sound and light alarm on site ● Explosion proof grade Exia Ⅱ CT6 Ga ● High precision, long-life impo
Product details
brand NGP/High Quality Technology Origin category domestic
  Fixed wireless acetylene detector
Gas detection: acetylene
Measurement range: 0-10ppm, 20ppm, 50ppm, 100ppm, 200ppm, 500ppm, 1000ppm, 5000ppm, 0-100% LEL
Resolution: 0.01ppm, 0.1ppm, 0.1% LEL
Detection principle: Electrochemical and catalytic combustion optional
Detection methods: fixed, wireless detection, diffusion measurement, pump suction measurement optional
Installation methods: wall mounted, pipe mounted, and flow-through options are available
Accuracy: ± 3% FS
Display mode: LCD display (optional)
Response time: ≤ 30 seconds
Recovery time: ≤ 60 seconds
Explosion proof mark: Exia Ⅱ CT6 Ga
A、 Suitable for Zone 0, Zone 1, Zone 2, locations containing explosive gas mixtures of Class IIA-IIC and T1-T6;
B、 The product has passed the inspection of the National Explosion proof Electrical Product Quality Inspection Center and obtained the Explosion proof Certificate of Conformity;
Explosion proof connection thread: 3/4'NPT
Output signal: Users can choose according to their actual requirements. It can transmit up to 2000 meters (single core 1mm ² shielded cable) and supports wireless transmission without wiring
Three wire system 4-20mA current signal output, relay output, alarm output
RS-485 digital signal output, combined with signal transmitter and receiver for long-distance wireless transmission
1 set of relay output: passive electric shock capacity 220VAC 3A, 24VDC 3A (optional)
Related accessories: 1 set of data acquisition hose, 1 signal transmitter and 1 receiver each
Supports RS485 serial port output and direct communication with computers for synchronous monitoring
Working temperature: -20 ℃~+50 ℃
Relative humidity: 10% to 95% RH (non condensing)
Power supply: 24VDC ± 12VDC
Maximum power consumption: 2.5W
Weight: Approximately 1.5Kg