A fluid concentration online measurement device specifically developed for solid-liquid two-phase fluids with high concentration and wide range of concentration changes. Compared to the commonly used radiation concentration meter in iron mines, this concentration meter has outstanding advantages: firstly, it avoids the difficulties in safety and management caused by the use of radioactive sources, as well as the potential harm to the health of employees; At the same time, it solves the problem that the radiation concentration meter cannot accurately measure concentrations that vary over a large range.
Introduction to FWC&D-A1 Capacitive Concentration Meter and Density Meter Products | |
Product Introduction |
A fluid concentration online measurement device specifically developed for solid-liquid two-phase fluids with high concentration and wide range of concentration changes. Compared to the commonly used radiation concentration meter in iron mines, this concentration meter has outstanding advantages: firstly, it avoids the difficulties in safety and management caused by the use of radioactive sources, as well as the potential harm to the health of employees; At the same time, it solves the problem that the radiation concentration meter cannot accurately measure concentrations that vary over a large range. |
measuring principle |
Adopting relative capacitance method and self sampling measurement method. Select two measuring tube segments with the same cross-section and length, install a pair of electrodes on the measuring tube, apply a stable high-frequency sine signal to the electrodes, and measure the capacitance of solid and liquid two-phase fluids and the capacitance of pure liquid objects separated from solid and liquid two-phase fluids, respectively. The capacitance size is related to the density and concentration of the measured medium. |
Technical features of the product |
(1) Multi purpose, synchronous measurement: volume concentration, mass concentration, and density of solid and liquid two-phase flow; |
(2) Realize high-precision, online continuous measurement for solid and liquid two-phase flow with large range of concentration and density changes; | |
(3) On site calibration does not require downtime, with a single sampling calibration process that is concise and efficient; | |
(4) No movable parts, stable and reliable long-term operation; | |
(5) No radioactive source, safe operation, no need for daily maintenance. | |
Parameters | |
measuring range |
0~75%M/M |
measurement accuracy |
±0.5% F.S |
repeatability |
±0.1% |
Measurement medium |
Solid liquid two-phase fluid |
Dielectric conductivity |
≤10S/m |
Maximum temperature of the medium |
≤96℃ |
Sampling tube diameter |
DN12 |
Sampling tube material |
UHMWPE (3 million molecular units) |
Electrode material |
316 stainless steel |
ambient temperature |
-40℃ ~ 65℃ |
Working pressure |
0.1MPa ~ 4.0MPa |
output signal |
4 ~ 20mA,RS485 |
protection grade |
IP54 |
Connecting flange |
GB9115 |
power supply |
220VAC |
power consumption |
5W |
communication |
RS485 |
Installation form |
Integrated and split type |
Application |
Accurate measurement of density/concentration of solid-liquid two-phase fluids such as drilling mud, cementing mud, slurry, coal water slurry, flotation fluid, drilling mud, fracturing slurry, and heavy medium beneficiation, as well as the inflow sediment volume and effluent turbidity in the water treatment industry |