★ Overview

Scope of Application

FB0803 Industrial Diffusion Silicon Pressure Transmitter

Industrial site process pressure detection and control

Ships and Navigation Systems

Aircraft and aviation systems

Air separation equipment and thermal and hydroelectric units

Gas and oil pipelines

Boiler pipeline pressure control

FB0803X miniature diffusion silicon pressure transmitter

Hydraulic and pneumatic control system

Industrial process detection and control

Laboratory pressure calibration

Engine, internal combustion engine

■ Locomotive braking system

Refrigeration and air conditioning units

■ Thermal power unit

Compressor, gas dispenser

● FB0803Z sanitary diffused silicon pressure transmitter (no inlet hole, no cavity, flat membrane structure, anti scaling)

■ Food

■ Medicine

■ Hygiene

■ Brewing

★ Features

Stable output with high sensitivity

The output of a typical strain gauge sensor is only about 10mv, while the full-scale output of a diffusion silicon sensor is about 100mv. The interference and noise factors have relatively small effects, greatly improving the resolution, and there is no dead zone near zero pressure.

High precision and good repeatability

The diffusion silicon piezoresistive pressure sensor realizes pressure sensing, pressure transmission, and electrical conversion on the same component, without intermediate conversion links, pressure hysteresis, or mechanical displacement deformation, ensuring minimal repeatability and hysteresis errors, with good linearity, stability, reliability, and long service life.

Good temperature characteristics

Due to the use of advanced technologies such as laser resistance adjustment and computer compensation, as well as clever control of diffusion concentration, full range temperature drift (sensitivity temperature coefficient) self compensation is achieved. Overcoming the defect of high temperature coefficient in semiconductor chips, the zero position and full temperature drift of the transmitter have reached a high level, expanding the operating temperature range.

Suitable for applications in hazardous and explosive fields and locations

The diffusion silicon pressure transmitter has the characteristics of low current, low voltage, and low power consumption, and belongs to the intrinsic safety explosion-proof product. It has obtained the explosion-proof certificate issued by the national safety explosion-proof organization.

High reliability and anti-interference performance

The product is made of stainless steel material and has a special protective structure. The circuit is designed with a series of protection measures such as lightning protection, anti-interference, overvoltage, and overcurrent, which improves the ability to seal and resist corrosion and harsh working environments. It is fully suitable for the needs of general industrial field measurement and control.

★ Technical parameters

technical indicators

● Target audience

Liquid, gas or vapor

● Measurement range

Gauge pressure: 0-10kPa~60MPa, absolute pressure: 0-100kPa~10MPa

Negative pressure: -0.1MPa to 2MPa

● Output

4~20mADC

● Power supply

12~30VDC

● Load characteristics

4-20mADC two-wire load R ≤ 50 (V-12) Ω

● Temperature range

Environmental temperature -20 ℃~+70 ℃; Standard medium temperature -20 ℃~+80 ℃

● Shell protection

Better than IP65

Explosion proof type

Explosion proof Exd Ⅱ CT6; The intrinsic safety Exia Ⅱ CT6 should be equipped with an external safety barrier

performance metrics

● Comprehensive accuracy

Accuracy level: ± 0.1%, ± 0.25%, ± 0.5%

● Stability

Better than ± 0.1% FS/year

● Temperature impact

Within the range of -20 ℃ to+70 ℃, the variation is less than ± 0.18%/10 ℃

● Vibration impact

When the vibration frequency is 20-200Hz in any direction, the change is less than ± 0.02% FS

● Impact impact

After a 100G impact in any direction for 11ms, the change is less than ± 0.02% FS

● Load impact

As long as the terminal voltage of the input transmitter is higher than 12V, there will be no load impact

● Location impact

The installation position does not affect the zero point

Structural indicators

● Structural materials

Shell: Polyurethane baked paint low copper cast aluminum alloy

The contact medium material is related to the type of sensor selected and the sealing method used

O-ring sealing structure: Fluororubber

● Process connection

Standard M20 × 1.5 external thread provided

● Electrical connection

It can be led out from any outlet as needed, suitable for industrial cables with diameters ranging from φ 8.5 to φ 10.0 as leads for sealing The universal cable connector PG16 or M20 × 1.5 can be used for the lead out joint, and the non lead end should be sealed with an end cap

★ Selection Table

FB0803 Industrial Diffusion Silicon Pressure Transmitter Selection Table

FB0803

Diffuse silicon pressure transmitter

code name

Measurement range (please specify the factory range when ordering; if not specified, the highest rated range shall be used for factory delivery)

02

0~1kPa~2.5kPaNote 1

03

0~2.5kPa~7kPaNote 1

04

0~7kPa~20kPa

05

0~10kPa~35kPa

06

0~20kPa~70kPa

07

0~35kPa~100kPa

08

0~70kPa~200kPa

09

0~100kPa~350kPa

10

0~200kPa~700kPa

11

0~350kPa~1.0MPa

12

0~700kPa~2.0MPa

13

0~1.0MPa~3.5MPa

14

0~2.0MPa~7.0MPa

15

0~3.5MPa~10MPa

16

0~7.0MPa~20MPa

17

0~10MPa~35MPa

18

0~20MPa~60MPa

code name

output signal

E

4~20mADC

S

Intelligent 4-20mADC two-wire system+fieldbus HART protocol

9

Special requirements

code name

accuracy class

1

0.1%

2

0.25%

3

0.5%

code name

process connection

R

Standard M20 × 1.5 external thread

T1

Plane membrane G1/2 external threadNote 2

O

Process according to the size provided by the user

code name

option

d

Explosion proof ExdII CT6

i

Intrinsic safety ExiaICT6

M1

Simulated indicator header

M3

3 1/2LCD digital display header

G

Gauge pressure measurement

A

Absolute pressure measurement (customized according to user agreement)

F

Negative pressure measurement (customized according to user agreement)

S

Radiators and process connectors

Y

User agreement

FB0803 05(0~30kPa) E

3

R

i G

Example of transmitter selection

Note 1: When using measurement range codes 02 and 03, they are suitable for measuring non corrosive, dust-free, and dry gases;

Note 2: Use measurement range code 07 or above (including 07).

1199RFW type flange mounted remote transmission flange pressure transmitter

1199EFW type plug-in remote transmission flange pressure transmitter

1199RTW thread mounted remote flange pressure transmitter

1199PFW flat remote flange pressure transmitter

1199CAP capillary tube

FB1151DP/GP type remote differential pressure/pressure transmitter

FB1151HP type high static pressure differential pressure transmitter

FB1151DR type micro differential pressure transmitter

FB1151DP differential pressure transmitter

FB1151AP type absolute pressure transmitter

FB1151GP type gauge pressure transmitter

FB0803 Industrial Diffuse Silicon Pressure Transmitter_FB0803 Pressure Transmitter_FB0803 Transmitter Selection, Price, Parameters, Industrial Diffuse Silicon Transmitter

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!