Xi'an Xihong Automation Equipment Co., Ltd
Home>Products>FB0802 Ceramic Capacitive Pressure Transmitter | FB0802 Pressure Transmitter | FB0802|
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    2-5 floors, Jingxinli Building, West Chang'an Avenue, Chang'an District, Xi'an City
Contact Now
FB0802 Ceramic Capacitive Pressure Transmitter | FB0802 Pressure Transmitter | FB0802|
★ Overview FB0802 Ceramic Capacitive Pressure Transmitter adopts internationally advanced ceramic capacitive sensors, combined with high-precision ele
Product details

★ Overview

The FB0802 ceramic capacitive pressure transmitter adopts internationally advanced ceramic capacitive sensors, combined with high-precision electronic components, and is assembled through strict manufacturing processes. It adopts dry pressure measurement technology without intermediate liquid, fully utilizing the technical advantages of ceramic sensors, making the pressure transmitter have excellent technical performance. It has strong overload and impact resistance, high stability, and high measurement accuracy. FB0802 ceramic capacitive pressure transmitter has multiple models, ranges, process connection forms and materials, and can be widely used in many industrial fields such as petroleum, chemical, power, metallurgy, pharmaceuticals, food, etc. It can adapt to various occasions and media of industrial measurement and is an ideal upgraded product for traditional pressure gauges and pressure transmitters. It is also an ideal pressure measuring instrument in the field of industrial automation.

★ Features

Strong resistance to overload and impact

Overvoltage can reach several to a hundred times the range.

High precision and good repeatability,high stability

Better than 0.1% F.S/year

Small temperature drift

Due to the elimination of the intermediate liquid in the measuring element, the sensor has achieved high measurement accuracy and is less affected by temperature.

Strong anti-interference ability

Waterproof, dustproof, vibration proof, explosion-proof, and anti-corrosion.

Easy installation

The product has a reasonable structure, small size, light weight, and can be installed directly at any position.

★ Technical parameters

technical indicators

● Target audience

Liquid, gas or vapor

● Measurement range

Gauge pressure: 0-2kPa to 7MPa;

Absolute pressure: 0-20kPa to 100kPa;

Negative pressure: -100kPa~7MPa

● Output

4~20mADC

● Power supply

12~30VDC

● Load characteristics

4-20mADC two-wire load R ≤ 50 (V-12) Ω

● Temperature range

Environmental temperature -20 ℃~+70 ℃; Standard medium temperature -20 ℃~+80 ℃

● Shell protection

Better than IP65

Explosion proof type

Explosion proof Exd Ⅱ CT6; The intrinsic safety Exia Ⅱ CT6 should be equipped with an external safety barrier

performance metrics

● Accuracy

Accuracy level: ± 0.25%, ± 0.5%

● Stability

Better than ± 0.1% FS/year

● Temperature impact

Within the range of -20 ℃ to+70 ℃, the variation is less than ± 0.18%/10 ℃

● Vibration impact

When the vibration frequency is 20-200Hz in any direction, the change is less than ± 0.02% FS

● Impact impact

After a 100G impact in any direction for 11ms, the change is less than ± 0.02% FS

● Load impact

As long as the terminal voltage of the input transmitter is higher than 12V, there will be no load impact.

● Location impact

The installation position does not affect the zero point

Structural indicators

● Structural materials

Diaphragm: Aluminum oxide ceramic

Shell: Polyurethane baked paint low copper cast aluminum alloy

FB0802 pressure transmitter contact medium material: stainless steel 316L

O-ring sealing structure: polytetrafluoroethylene or fluororubber

● Process connection

Standard M20 × 1.5 external thread provided

● Electrical connection

It can be led out from any outlet as needed, suitable for industrial cables with diameters ranging from φ 8.5 to φ 10.0 as leads for sealing The universal cable connector PG16 or M20 × 1.5 can be used for the lead out joint, and the non lead end should be sealed with an end cap.

Selection Table

FB0802

Industrial ceramic capacitive pressure transmitter

code name

measurement range

01

0~2kPa~7kPa

02

0~7kPa~20kPa

03

0~20kPa~50kPa

04

0~50kPa~100kPa

05

0~100kPa~200kPa

06

0~200kPa~500kPa

07

0~500kPa~1.0MPa

08

0~1.0MPa~2.0MPa

09

0~2.0MPa~4.0MPa

10

0~4.0MPa~7.0MPa

code name

output signal

E

4~20mADC

S

Intelligent 4-20mADC two-wire system+fieldbus HART protocol

9

Special requirements

code name

accuracy class

2

0.25%

3

0.5%

code name

process connection

R

Standard M20 × 1.5 external thread

P

M42 × 1.5 external thread

O

Process according to the size provided by the user

code name

option

d

Explosion proof ExdIICT6

i

Intrinsic safety ExiaICT6

M1

Simulated indicator header

M3

3 1/2LCD digital display header

G

Gauge pressure measurement

A

Absolute pressure measurement (customized according to user agreement)

F

Negative pressure measurement (customized according to user agreement)

S

Radiators and process connectors

Y

User agreement

FB0802 03(0~40kPa) E

3

R

i G

Example of transmitter selection

FB0803G diaphragm pressure transmitter

FB0803 Precision/Sanitary Diffusion Silicon Pressure Transmitter

FB0803 Industrial Diffusion Silicon Pressure Transmitter

FB0802 Ceramic Capacitive Pressure Transmitter

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!