Shenzhen Kerei Technology Development Co., Ltd
Home>Products>F905 Low Noise 3D Flux Gate Sensor
F905 Low Noise 3D Flux Gate Sensor
F905 Low Noise 3D Flux Gate Sensor
Product details


Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G92

hall

handheld

1

1%

10T

10μT

G93

hall

handheld

3

1%, 0.5%

20T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G203

hall/reluctance

Desktop computer

3

0.2%

10T

10nT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%

10T

Output: ±3V

GSP301D

hall

Digital transmitter

1

1%, 0.2%

10T

1μT

GSP303D

hall

Digital transmitter

3

1%, 0.2%

20T

1μT

GSP303D-S

hall

Digital transmitter

3

0.5%, 0.1%

3T

1μT

Magnetic field testing system

GAS3000

Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location

GMS980

High precision Gaussian meter calibration system (High precision Tesla meter calibration device)

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF601

fluxgate

handheld

1

0.5%

1mT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

GFP703S

fluxgate

Spectrum analyzer

3

0.5%

1mT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

G1000

reluctance

Smart Transmitters

3

DC- 1% AC- 2%

400μT/ Axis

DC- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

GSP301HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

GSP303HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

10 to 20pT

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

F23

fluxgate

split type|large range

3

<>

1500μT

±10V,single-ended

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

Magnetic flux gate sensor data acquisition unit

FDU301

Connectable1A three-axis flux gate sensor

ASA1000

Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor

AFS

Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters

GMR-16

Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor

GR100

Digital three-axis flux gate gradiometer

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model



Tag: Three dimensional flux gate sensor, three-axis flux gate probe, three component flux gate Mag-13 Mag-03, three-axis magnetometer, weak magnetic measurement, geomagnetic measurement

F905 Low Noise 3D Flux Gate Sensor


sketch:

The F905 low-noise 3D flux gate sensor is a high-level 3D flux gate sensor that can directly convert magnetic field strength into analog signals (± 10V). Typical application scenarios include geomagnetic detection, package detection, underwater magnetic field monitoring, traffic monitoring, residual magnetism measurement, weak magnetic field measurement, laboratory, etc.

The F905 low-noise 3D flux gate sensor has a measurement range of ± 70 μ T and ± 100 μ T, with a frequency response of DC-3kHz; In addition, F905 also has excellent linearity (<><><6ptrms hz='' at=''>6ptrms>

The packaging types of F905 low-noise 3D flux gate sensor can be divided into standard packaging and submersible packaging. The protection level of standard packaging is IP67; And the submersible level packaging can support work at a depth of 2000 meters underwater, making it very suitable for underwater magnetic field monitoring and measurement.






characteristic

High level 3D flux gate sensor

Excellent linearity:<>

Excellent orthogonality:<>

Power supply:±12V ~ ±17Vperhaps5- 36VDC

analog signaloutput(±10V)

Can be used for underwater magnetic field monitoring and measurement

Measurement range options:±70μTand±100μT

Frequency response range:DC- 3kHz

Noise level: as low as<6ptrms hz='' at=''>6ptrms>

Standard packaging,IP67protection grade

Optional diving grade packaging(underwater2000rice)

Optional temperature sensor(High precision±0.2)



F905Three dimensional flux gate sensor parameters:

model

F905

performance parameter

number of axles

3

range

X,Y,Z

±70μT

±100μT

vectorR

121μT

173μT

bandwidth(-3dB)

> 3kHz

Internal noise level

Standard version:6 to ≤10pTrms/√Hz at 1Hz

Low noise version(“L”)<>Hz at 1Hz

Start Time

150ms

Warm-up time

15mins

zero drift error

≤±5nT

Zero drift temperature coefficient

±0.3nT/

Magnetic field simulation signal

(Output voltage)

±10 V/axle(unbalanced, single ended ref. 0V)

sensitivity

14.3mV/μT

10mV/μT

Simulate output impedance

< 10=''>

Voltage calibration error

±0.3%

temperature coefficient

≤±15ppm/

≤±20ppm/

Orthogonality error

<>

linearity error

<>least-squares fit)

hysteresis

<2nt>2nt>Exposed to magnetic field environments up to twice the range)

Temperature sensor specifications(optional)

measuring range

-40°Cto+90°C

type of output

voltage

Output voltage

943.227mV at 30°C

output scaling

-5.194mV/°C

accuracy

±0.2°C (Within the entire measurement range of the temperature sensor)

Specification of 3D Flux Gate Sensor

operation temperature

- 40 to +70

storage temperature

- 40 to +85

Connecting cable length

standard1.5m (Other lengths can be customized)

power consumption

1.5W

power supply

±12Vto±17Vperhaps5- 36VDC

protection grade

IP67Or submersible grade packaging, supporting underwater operations2000Rice work

size

197 mmW× 32 mmH× 32 mmD

weight

135g

qualification

CECertificationEMCauthentication






Three dimensional flux gate sensormodel selection

F905

L

-100

-S

T

Three dimensional flux gate sensor types

F905Low noise 3D flux gate sensor

noise level

Default:6 to ≤10pT

L<>

Sensor range

-7070μT/axle

-100100μT/axle

Power source

S5- 36VDC

P±12Vto±17V

Built in temperature sensor

-Thave

BLANK: No



Note:

1. Model example:F905L-100-STThis is a low-noise 3D flux gate sensor(F905)The noise level is<6ptrms/√ hz='' at=''>(L)The range is 100 μ T/axis(100)The power type is 5-36VDC(S)Built in temperature sensor(-T)

2. The default cable length for the 3D flux gate sensor is 1.5m, and other lengths can be customized;

3. The default packaging level for the 3D flux gate sensor is IP67. If you need a submersible version packaging (supporting work at 2000 meters underwater), please contact Colin.








Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!