Exquisite pressure switch
■ Pressure measurement setting range 0.6 bar~400 bar ■ Return setting value optional ■ Wide measurement range, overload capacity up to 1000 bar ■ With
Product details
Product Application
■ Wind turbine host, hydraulic transmission equipment
Food and pharmaceutical pipelines
Boiler and power plant
Pressure measurement of water, oil, and gas media
Industries such as electricity, metallurgy, glass, chemical, rubber, and textile
Technical data
| Measurement range | 0.6bar~400bar |
| Fixed hysteresis | 10% to 20% set value (standard) |
| 1% to 5% set value (optional) | |
| 25% to 35% set value (optional) | |
| medium temperature | -20 ℃~85 ℃ (standard) |
| -40 ℃~-160 ℃ (customized) | |
| precision error | 3% set value |
| Protection level | IP65 |
| ambient temperature | -25℃~80℃ |
| ambient humidity | 5%~95% |
| signal output | SPDT contact gold plating |
| Contact capacity | ≤DC 42V,1A |
| ≤DC 42V,3A | |
| ≤DC 115V,0.15A | |
| ≤DC 125V,3A | |
| sensor type | Thin film type: measurement value 0.2~50bar |
| Maximum working pressure 150bar | |
| Maximum safe pressure 300bar | |
| Piston type: measurement value of 50-400 bar | |
| Maximum working pressure 450 bar | |
| Maximum safe pressure 1000bar | |
| working life | 1 million times |
| Product weight | 0.1KG |
Instructions
·When installing the pressure switch, it can be installed horizontally or vertically in a forward direction, but be careful not to install it upside down;
·Adjust switch point: Loosen the top bolt of the Husman plug, remove the protective cover and female plug, use a hex wrench to adjust the size of the switch point, clockwise to increase and counterclockwise to decrease;
Online inquiry