■product overview
The electronic electric single seat regulating valve is composed ofComposed of 3810L/PSL series electronic electric actuators (intelligent integrated actuators) and single seat regulating valves. The electronic electric actuator is equipped with a built-in servo system and does not require a separate servo amplifier. It can be controlled with input signals and power supply to operate. The electronic actuator has simple connection, and the single seat regulating valve core adopts a top guided sealing performance, which is suitable for situations with strict leakage requirements, small pressure difference before and after the valve, and certain viscosity or fiber like media.
■Main component materials
Valve body and valve cover:WCB(ZG230—450)、CF8(ZG1Cr18Ni9Ti)、CF8M(0Cr17Ni12Mo2)、
Valve core:1Cr18Ni9Ti、 Si Ti Lai alloy overlay welding, reinforced polytetrafluoroethylene
Packing: PTFE, flexible graphite, stainless steel corrugated pipe
Push rod and liner:2Cr13
Sealing gasket: rubber asbestos board1Cr18Ni9Ti、 Graphite wrapped gasket
Valve stem:304、316、326L、17-4PH
■Main technical parameters
|
G3/4” |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
|||||||||||
Valve seat diameter mm |
3 |
4 |
5 |
6 |
7 |
8 |
10 |
12 |
15 |
20 |
26 |
32 |
40 |
50 |
66 |
80 |
100 |
125 |
150 |
200 |
|||
Rated flow coefficient kv |
0.08 |
0.12 |
0.20 |
0.32 |
0.5 |
0.8 |
1.2 |
2.0 |
3.2 |
5.0 |
8.0 |
12 |
20 |
32 |
50 |
80 |
120 |
200 |
280 |
450 |
|||
Nominal pressure (MPa) |
1.6 4.0 6.4 (normal temperature), 4.0 6.4 (medium temperature), 0.6 4.0 6.4 (low temperature) |
||||||||||||||||||||||
Travel distance (mm) |
10 |
16 |
25 |
40 |
60 |
||||||||||||||||||
Action speed mm/s |
4.2 |
2.1 |
3.5 |
1.7 |
3.4 |
||||||||||||||||||
Working temperature ℃ |
straight line |
Straight line, equal percentage longitude |
|||||||||||||||||||||
Flange medium |
-20 ℃~+200, -40~+250 (normal temperature) -40~+450 (medium temperature) -250~-60 (low temperature) |
||||||||||||||||||||||
Flange size |
Cast iron flanges according to JB78-59, cast steel flanges according to JB79-59 |
||||||||||||||||||||||
flange type |
The flange sealing type shall be in accordance with JB77-59, the cast iron flange shall be smooth, the cast steel flange shall be concave, and the low-temperature flange shall be quasi groove |
||||||||||||||||||||||
valve |
state-owned |
0.6 |
Low temperature: -250 ℃~-60 ℃ ZG1r18Ni9Ti |
||||||||||||||||||||
1.6 |
Room temperature: -20 ℃~+200 ℃ Ht200 |
||||||||||||||||||||||
4.0 |
Room temperature: -40 ℃~+200 ℃ ZG230-450, ZG1Cr18Ni9Ti |
||||||||||||||||||||||
Medium temperature: -40 ℃~-450 ℃ ZG230-450, ZG1Cr18Ni9Ti |
|||||||||||||||||||||||
Low temperature: -250 ℃~-60 ℃ ZG1Cr18Ni9Ti |
|||||||||||||||||||||||
6.4 |
Room temperature: -40 ℃~+200 ℃ ZG230-450, ZG1Cr18Ni9Ti |
||||||||||||||||||||||
Medium temperature: -40 ℃~-450 ℃ ZG230-450, ZG1Cr18Ni9Ti | |||||||||||||||||||||||
Low temperature: -250 ℃~-60 ℃ ZG1Cr18Ni9Ti | |||||||||||||||||||||||
Valve core material |
1Cr18Ni9 |
||||||||||||||||||||||
Upper valve cover type |
Ordinary type (room temperature), hot plate type (medium temperature), long force type (low temperature) |
||||||||||||||||||||||
Equipped with electric actuator model |
361LSA-08 |
361LSA-20 |
361LSB-30 |
361LSB-50 |
361LSC-65 |
||||||||||||||||||
361LXA-20 |
361LXB-30 |
361LXB-50 |
|||||||||||||||||||||
Note: Can be provided to usersThe flange spacing of products that comply with national flange standards such as ANSI, JPI, and JPI is determined according to user needs.
■Execution mechanism parameters
|
Rated output force N |
Speed mm/s |
Technical Parameter |
361LSA-08 |
800 |
4.2 |
Power supply: AC220V 50Hz |
361LSA-20 |
2000 |
2.1 |
|
361LSB-30 |
3000 |
3.5 |
|
361LSB-50 |
5000 |
1.7 |
|
361LSC-65 |
6500 |
2.8 |
■performance index
|
Indicator value |
||
Basic error% |
±2.5 |
||
Return difference% |
2.5 |
||
Dead zone% |
1.0 |
||
Constant point deviation% |
teletransmission |
Starting point |
±2.5 |
End |
±2.5 |
||
Electricity off |
Starting point |
±2.5 |
|
End |
±2.5 |
||
Rated travel deviation% |
2.5 |
||
Allowable discharge rate L/H |
10-4 times the rated capacity of the valve |
||