【 Product Introduction 】: The Y09-6E laser dust particle counter is used for particle counting, with real-time display of particle data in 6 channels
Product details

产品概述

Y09-6E-1

The Hongji Clean Y09-6E Laser Dust Particle Counter (2.83L/min) is a detection instrument used to measure and analyze the size and quantity of dust particles per unit volume of air in clean environments, and to determine the cleanliness level of clean environments according to standards.
Widely used for clean room testing in enterprises such as medicine and health, optics, chemistry, food, cosmetics, electronics, biological products, aerospace, etc.


工作原理

Particles in the air scatter when exposed to light, a phenomenon known as light scattering. Light scattering is related to factors such as particle size, wavelength of light waves, refractive index of particles, and their light absorption characteristics. However, in terms of scattered light intensity and particle size, there is a basic rule that the intensity of scattered light from particles increases with the increase of their surface area. In this way, by measuring the intensity of scattered light, the size of particles can be inferred, which is the basic principle of light scattering particle counters.

尘埃粒子计数器工作原理图-435x480-20170524

工作过程简述

QQ图片20170612143920

Y09-6E provides a constant velocity sampling head connected to the sampling port through a hose. The constant velocity sampling head helps to reduce counting errors in sampling small particles and should be used in each measurement. When sampling typical indoor and outdoor aerosol particles, the constant velocity sampling head should always face upwards. The instrument can be held in the hand or placed on a flat surface or tripod, with the LCD screen facing the operator.

In places where constant airflow is sampled, such as clean rooms, ducts, downstream of filters, etc., the direction of airflow flow is always aligned with the opening of the constant velocity sampling head.

The hose connecting the constant velocity sampling head and sampling port can be extended if necessary. However, a longer length will increase the burden on the sampling pump, reduce the airflow velocity, and cause premature failure of the sampling pump. It can also cause counting loss, especially an increase in counting loss for large particles. It is recommended to shorten the length of the hose as much as possible, and its length should not exceed 4 feet.

The sampling height can also affect readings, and readings near the floor may be several times higher than readings at line of sight height.

When using Y09-6E to analyze pollution issues, it is important to note whether all pollution is continuous and whether some is the result of short-term events or a burst of particles. Multiple samples must be taken at the same location to determine the source of pollution.

技术特点

Y09-6E-2

The sampling volume is 2.83 liters per minute, and the system includes confidence level UCL measurement that does not require manual calculation

Y09-6E-3

Lithium batteries can be fully charged and used sustainably for more than 8 hours

The aviation aluminum shell is not prone to dust accumulation, easy to clean, and has a beautiful appearance

IMG_0809-a

6 particle size channels: 0.3, 0.5, 1.0, 3.0, 5.0, 10 μ m

IMG_0810-a
QQ图片20170612150830

LCD screen display, simultaneous measurement and display of various particle sizes

QQ图片20170612143152

1000 sets of data storage, real-time printing of data, internal storage

Optional software for computer connection

QQ图片20170612150846

Handheld design, convenient to carry and measure at any time

QQ图片20170612151051

性能参数


Overall dimensions:205*260*125mm
Display mode:Digital tube displayLCD



Weight:3.2Kg
power waste:40W



power supplyAC220V±10%,50Hz
Particle size channel: 0.3, 0.5, 1, 3, 5, and 10 µ m can directly display particle concentration



light sourceSemiconductor laser (with a lifespan greater than 30000 hours)
Sampling traffic:2.83L/min



Sampling period1-10 minutes self setting
Alarm level: 95% UCL value



Printing:Built in thermal printer
Data storage:1000 sets



Self purification time:≤10min
working hours:8 hours



Standard accessories:Isokinetic sampling head, sampling tube, sampling bracket, instruction manual, certificate of conformity, factory inspection report, warranty card
Optional parts:Measurement auxiliary vehicle (with rechargeable power supply, can be used continuously for 6 hours after charging), PC remote control card and dedicated software