Multi functional and high-precision

Ideal choice for power SCADA system
● Intuitive display, easy to learn and use
Real time measurement of multiple electrical parameters, supporting dual energy accumulation

Remote power control

Integrating remote signaling, telemetry, remote control, and measurement.

Comes with rich and flexible I/O functions

Industrial standard RS-485 communication interface and MODBUS communication protocol

Ultra small design, safe and convenient

Good safety, high reliability/intuitive display, easy to learn and use

Self locking installation

External modules can be plugged in, which can better reduce space.

major function

Real time measurement of phase voltage, line voltage, current, active power, reactive power, apparent power, power factor, three-phase active power, three-phase reactive power, three-phase apparent power, three-phase power factor, frequency, etc.

● Supports dual energy accumulation, which means it can measure both conventional energy and rate energy. The former includes forward active energy, reverse active energy, forward reactive energy, reverse reactive energy, total active energy, and total reactive energy, respectively.

The latter includes forward active energy, reverse active energy, forward reactive energy, and reverse reactive energy.

● Statistics and recording of demand.

Measurement of power quality such as voltage imbalance, current imbalance, three-phase voltage harmonic content, three-phase current harmonic content, voltage odd, even distortion rate, current odd, even distortion rate, voltage peak coefficient, current K Factor, etc.

● Expandable external I/O module, which can be connected to 8 switch input modules (A), 4 switch input and 2 switch output modules (A), 6 analog input (voltage/current) modules (A), 2 switch output modules (B), 4 analog temperature acquisition modules (B), and 2 analog input (voltage/current) modules (B). The external module can be installed as any single module or any combination of an A-type module and a B-type module.

performance parameter

performance

parameter

Losing

enter

measure

measure

apparent

show

electricity

press

range

AC100V, 250V, 400V, etc. can be pre selected (with a measurement range of 80%~120% of the full range), with a default of 250V.

overload

1.2 times the range input can measure correctly; Instantaneous (<10 cycles) voltage 3 times the range without damage

accuracy

RMS measurement (voltage accuracy: 0.2 level)

impedance

Voltage channel ≥ 100k Ω/V

electricity

flow

range

AC1A, 5A, etc. can be reserved for selection.

The default range is 5A, the maximum current is 6A, and the nominal current is 1.5A.

overload

1.2 times the range input can measure correctly; Instantaneous (<10 cycles) current 5 times

accuracy

RMS measurement (current accuracy: 0.2 level)

impedance

Current channel ≤ 10M Ω

frequency

Three phase AC 50/60Hz voltage and current; Input frequency: 40-70Hz

power

Accuracy of active and reactive power: Level 1;

External simulation module

Linear accuracy: ≤±0.5%;

Power factor

Power factor accuracy: Level 0.5;

electric energy

Active Level 1

Reactive power level 2

power supply

power supply

AC 85V~264V(50/60Hz)

EMC

Group pulse test

±4kV

Lightning surge test

±4kV

Static electricity test(Air-Gap Discharge

±15kV

Voltage drop

Category 3

transport

go out

approve

weave

Cheng

open up or clear out by poking or jabbing

interrogate

output interface

RS-485 interface, two-wire system, ± 15kV ESD protection

Communication Protocol

Standard MODBUS-RTU communication protocol

data format

Can be set; 10 bits, 1 start bit 0, 8 data bits, 1 stop bit 1; Or 11 bits, which can be set by software for odd, even, or no verification;

COMMUNICATION RATE

BPS1200、2400、4800、9600、19.2k, Can be set

display

LCD segment code display

ring

area

work environment

Working temperature:-20~60℃

storage environment

Storage temperature:-30~80℃

relative humidity

Relative humidity ≤ 95%No condensation

peaceful

complete

pressure resistance

Input and power supply>4kV Input and output>4kV

Output and power supply>4kV output and output>4kV

isolation

Output, input, and power supply to the casing>5M Ω

External dimensions

Online inquiry