Automotive Painting Process
The appearance of the instrument adopts automotive spray painting technology, and is matched with elegant white and navy blue colors, showcasing the fusion of technology and fashion in Zhangxian Instrument.
Visual Sample Warehouse
The sample window is made of lead glass, and the sample can be directly observed during the testing process.
Multi sample testing
Multiple samples are tested continuously without human supervision, saving you valuable time.
● Optional single sample testing.
Short analysis time
Compared with ordinary EDXRF, the analysis time is shorter;
Ordinary EDXRF analysis time: 300 seconds, HeLeeX E9 analysis time: 60 seconds.
Vacuum/helium dual optical path
The first domestic and international vacuum/helium dual path system that can detect light elements such as Al, Si, P, S, Cl in solid, liquid, and powder samples.
radiation protection
Maze design, lead glass protection;
● X-ray tube rear irradiation;
Mistakenly operating the emergency system, quickly cutting off X-rays at 0.5uS;
Instrument radiation safety report issued by national authoritative institutions.
Easy to transport
There are four movable wheels at the bottom of the instrument, which can be fixed or moved as needed.
The weight of the instrument is 95Kg;
Easy to replace
The sample testing film is easy to replace;
Modular collimator and filter system, equipped with collimators of different materials and apertures for different customers and test samples.
Easy to operate
The software interface is simple and easy to operate, and can be learned in 30 minutes;
Equipped with an instrument operation flowchart, instrument operation and maintenance are simpler;
More accurate data
The software is equipped with three software algorithms, configured according to different materials;
● Independently develop high and low energy independent algorithms to effectively improve the resolution of low-energy elements;
Ordinary EDXRF resolution: 149eV, HeLeeX E9 resolution: 125eV;
Excellent light element analysis ability
Test for higher resolutions of P and S.
The standard deviation of S element is 20ppm.
The testing error is 5%.
Detector:
Type: X-123 detector (using original imported high-performance electrically cooled semiconductor detector)
● Be window thickness: 0.5mil
● Crystal area: 25mm2
● Best resolution: 125eV
● Signal processing system DP5
X-ray tube:
Voltage: 0~50kV
Maximum current: 2.0mA
Maximum power: 50W
Target material: Mo
● Be window thickness: 0.5mm
● Service life: greater than 20000 hours
high-voltage power supply:
Output voltage: 0~50kV
● Filament current: 0~2mA
Maximum power: 50W
Ripple factor: 0.1% (p-p value)
8-hour stability: 0.05%
camera:
● Micro focal length
● Drive free
5 million pixels
Collimator, filter:
Quick disassembly of collimator and filter system
● Multiple material collimators
Spot size: Φ 0.7mm, Φ 1.2mm, Φ 3.0mm, Φ 5.0mm
Multiple combinations of filters and collimators, automatically switched by software
Vacuum pump:
● Double stage rotary vane vacuum pump
Power: 400w
● Suction rate: 8m3/h
Other accessories:
Imported high-performance switching power supply
Imported low-noise, high air volume fan
● Dimensions: 470 mm x 560mm x 1030 mm (length x width x height)
Sample chamber size: Φ 188mm × 88mm (diameter x height)
● Instrument weight: 95kg
Power supply: AC220V/50Hz
Maximum power: 1000W
Working temperature: 15-30 ℃
Relative humidity: ≤ 85%, no condensation
Alloy analysis
• Can accurately detect elements such as Al, Si, P, S, Cu, Fe, Zn, Ni, Cr, Pb, Mn, Ag in alloys such as copper, steel, and tin
For light matrix alloys, it has excellent detection capability
Zero halogen detection
Vacuum extraction eliminates the interference of Ar in the air, achieving unprecedented stability and accuracy in chlorine measurement!
Toy safety
To cope with the detection of Pb, Cr, Ba, Hg, Cd, Sb, Se, As8 major elements in EN71-3 and ASTM963-11 instructions, as well as the detection of Pb, Cr, Ba, Hg, Cd, Sb, Se, As, Co, Cu, Zn, Mn, Sr, Sn, Ni element content in new toy instructions.
Coating thickness measurement
Various substrates plated with Au, Ag, Cu, Ni, Sn, Zn, Cr, etc
Response to RoHS Directive
120 seconds for detection results;
• World class stability and accuracy;
Multi sample automatic rotation testing;