E3-3D: Three dimensional positioning coating thickness measuring instrument
E3 is a universal energy dispersive X-ray fluorescence spectrometer (EDXRF) specifically designed for detecting coating thickness; Its core components
Product details

1.1 Fully automatic 3D sample stage


1.2 X-ray downward irradiation type, laser focusing


1.3 Small Spot Design


1.4 Flexibility adjustment of testing time


1.5 Multi specification sample warehouse


1.6 X-Ray detector

HeLeeX E3-3DAdopting the original imported X-123 semiconductor X-ray detector from the United States, it features advanced semiconductor cooling technology, high peak to back ratio (signal-to-noise ratio), ultra-high counting rate, superior resolution and stability, and high integration,Exceeding other brands or assembled detectors of the same brand.

detector

Type: X123 detector (original imported high-performance electrically cooled semiconductor detector)

● Be window thickness: 1mil

● Crystal area: 25mm2

● Best resolution: 145eV

● Signal processing system: DP5


X-ray tube

Voltage: 0-50V

● Maximum current; 2mA

Maximum power: 50W

Target material: Mo

● Be window thickness: 0.2mm

● Service life: greater than 2w hours


high voltage power supply

Output voltage: 0-50Kv

● Filament current 0-2mA

Maximum power: 50w

Ripple factor: 0.1% (p-p value)

8-hour stability: 0.05%


camera

● Focal length: Micro focal length

● Driver: No driver required

● Pixel: 8 million pixels


Collimator, filter

● System: Quick disassembly collimator, filter system

● Material: Multiple materials collimator

● Spot size: optional spot sizes of Φ 0.1mm, Φ 0.3mm, Φ 0.5mm, Φ 1.0mm, Φ 2.0mm, and Φ 4.0mm


Cross shaped laser head

Spot shape: Cross line

Output wavelength: Red light 650nm

Optical lens: Glass lens

● Size: Φ 10 × 30mm

● Divergence angle: 0.1-2mrad

● Working voltage: DC 5V

Output power:<>

Working temperature: -10~50 ℃


Other accessories

● Switching power supply: imported high-performance switching power supply

● Cooling fan: Imported low-noise, high air volume fan

● Dimensions: 360 mm x 600mm x 385 mm (length x width x height)

Sample compartment size: 360mm x 400mm x 160 (length x width x height, height can be customized)

● Instrument weight: 50kg

Power supply: AC220V/50Hz

Maximum power: 330W

Working temperature: 15-30 ℃

Relative humidity: ≤ 85%, no condensation

According to different matrix samples, three algorithms are equipped to increase the accuracy of sample testing.

Equipped with an open analysis model function, customers can create their own working models.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!