FMP56 is specifically designed for level measurement under working conditions such as solid material storage warehouses or tanks. Even in narrow storage compartments with severe dust or obstructed cabins, FMP56 can provide the most stable measurement values. FMP56 is used for continuous level measurement of solid bulk materials such as powders and granules. Measurement is not affected by dust, feed noise, temperature, or gas-phase media.
Advantages:
Maintain reliable measurement even under changing measurement product or process conditions
HistoROM integrated data storage unit brings fast and convenient debugging, maintenance, and diagnosis
Multi echo tracking innovative technology brings high reliability to measurement results
Hardware and software developed according to IEC 61508 standard, reaching SIL3 level
Seamless integration into control or device management systems
Intuitive guided menu (on-site or through system debugging) with Chinese menu display, reducing training, maintenance, and operational costs
Through the world's authoritative SIL and WHG experimental certification, save your time and economic costs
application area
Using cable measurement
Process connection: 3/4 'thread or variable diameter flange
Temperature: -40 to+120 ° C (-40 to+248 ° F)
Pressure: -1 to+16 bar (-14.5 to+232 psi)
Maximum measurement range: 12m (39ft)
Accuracy: ± 2mm (0.08 ')
International explosion-proof protection certification, 5-point linear protocol, WHG certification, EN10204-3.1 certification
Advantages:
Maintain reliable measurement even under changing measurement product or process conditions
HistoROM integrated data storage unit brings fast and convenient debugging, maintenance, and diagnosis
Multi echo tracking innovative technology brings high reliability to measurement results
Hardware and software developed according to IEC 61508 standard, reaching SIL3 level
Seamless integration into control or device management systems
Intuitive guided menu (on-site or through system debugging) with Chinese menu display, reducing training, maintenance, and operational costs
Through the world's authoritative SIL and WHG experimental certification, save your time and economic costs
application area
Using cable measurement
Process connection: 3/4 'thread or variable diameter flange
Temperature: -40 to+120 ° C (-40 to+248 ° F)
Pressure: -1 to+16 bar (-14.5 to+232 psi)
Maximum measurement range: 12m (39ft)
Accuracy: ± 2mm (0.08 ')
International explosion-proof protection certification, 5-point linear protocol, WHG certification, EN10204-3.1 certification