Beijing Xinghua Keyi Chemical Equipment Co., Ltd
Home>Products>Datapaq Oven Tracker System DP5 Datapaq炉温仪DP5型/Da...
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18903012669
  • Address
    Room 2610, Block A, Century Economic and Trade Building, No. 72 West Third Ring North Road, Haidian District, China 100048
Contact Now
Datapaq Oven Tracker System DP5 Datapaq炉温仪DP5型/Da...
Datapaq Oven Tracker Datapaq Furnace Temperature Tracker DP5, including Chinese version analysis software (switchable to English, German, French, Ital
Product details

Datapaq Oven Tracker DatapaqFurnace temperature trackerDP5Type, including Chinese version analysis software (switchable to English, German, French, Italian, Japanese, Korean, Vietnamese, etc.), computer networkingCI1150CI3029perhapsCI1020)TheData LoggerData collectorDP5(Replace)DQ1860ADP9061AandDP9061A)TheThermal Barrierhot boxTB0045TB0046TB5000TB0093TB0021TB4005TB2036TB2015TB2065TB2021TB2020TB2065TB2066TB2067TB2068TB2061TB2062TB2081TB2082A set of measuring headsProbes.

DP56Channel12Channel)DQ1860(Discontinued production) DP9061A/DP9064A(Discontinued production)

Data Loggerdata logger DP5 DP5560 6thoroughfare/DP5612 12thoroughfareUSBInterface, Bluetooth, and optional wireless transmissionTM

Range:-100to 1370℃ accuracy: ±0.5℃ resolution:0.1

Maximum operating temperature:85℃ (to ensure measurement accuracy, the recorder will be turned off and the operator will be warned at this temperature)

Sampling interval:0.05Seconds to10Minute adjustable

Start record: manual, temperature rise, time stop record: manual, temperature fall

Size/Weight:6thoroughfare11.7 x 106x 150 mm/Heavy0.3Kg 12Channel20 x 106x 165mm/Heavy0.3Kg

Storage capacity:50000A data/Channel storage10Measure once, charge once, run once25Hour by hour(1Sampling in seconds) or measurement20Secondary temperature

Charging time:1.5Hour (with charger) or14Hour (charging of sampling computer)

Bluetooth:5Reset within a range of meters/Download and real-time temperature reception

TB5000hot boxThermal Barrier

→ Insulation box TB5000 (including two heat absorbing blocks TB1001, suitable forDP5/TP3

weight
(kg)

size
(mm)

temperature
(℃)

Adiabatic time
(minutes)

6.2

130 (high)

100

870

190 (width)

150

390

292 (long)

200

270

250

210

300

180

TB0093

TB0093hot box(Silicon free design)Thermal Barrier(Silicon Free)

→ Insulation box TB0093(Including one heat absorbing block TB1001, suitable forDP5

weight
(kg)

size
(mm)

temperature
(℃)

Adiabatic time
(minutes)

4

122 (high)

150

180

188 (width)

200

120

297 (long)

250

90

→ Insulation box TB4005 (including one heat absorbing block, suitable for DQ)5660/TP3, used for curing enamel and glass powder)

weight
(kg)

size
(mm)

temperature
(℃)

Adiabatic time
(minutes)

6.2

125 (high)

200

360

248 (width)

400

120

409 (long)

800

60

Insulation box TB0045 (applicable toDP5660Data Collector

Weight (kg) 1.5

Dimensions (mm) 48 (height) × 185 (width) × 223 (length)

Temperature (℃) 100 150 200 250

Adiabatic time (minutes) 80 45 35 30

Insulation box TB0046 (applicable to D)P5660Data Collector

Weight (kg) 2.4

Dimensions (mm) 70 (height) x 195 (width) x 240 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 120 60 45 35 25

→ Insulation box TB0025 (applicable toDP5660Heat absorbing blockTB1089)

weight
(kg)

size
(mm)

temperature
(℃)

Adiabatic time
(minutes)

4.5

37(High)

150

120

278(Width)

200

90

306(Long)

250

45

Insulation box TB2028 (applicable to D)P5660Data Collector

Weight (kg) 0.2

Dimensions (millimeters) 24 (height) × 136 (width) × 195 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 9

Insulation box TB2003 (applicable to D)P5660Data Collector

Weight (kg) 1.5

Dimensions (mm) 40 (height) × 162 (width) × 216 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 45 25 20 18 15

Insulation box TB5001 (applicable toDP5660/TP3Data Collector

Weight (kg) 2.8

Dimensions (millimeters) 75 (height) x 176 (width) x 292 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 125 65 54 45 40

Insulation box TB5004 (applicable toDP5660Data Collector

Weight (kg) 4.2

Dimensions (millimeters) 50 (height) × 229 (width) × 271 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 285 165 105 75 60

Insulation box TB5006 (with 4 DQ placed)5660Data Collector

Weight (kg) 7

Dimensions (millimeters) 156 (height) × 190 (width) × 303 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 870 390 270 210 180

Insulation box TB2005 (applicable toDP5660Data Collector

Weight (kg) 4.2

Dimensions (mm) 68 (height) × 188 (width) × 368 (length)

Temperature (℃) 200 250 300 400 800

Adiabatic time (minutes) 45 37 30 22 10

Insulation box TB2015 (applicable toDP5660Data Collector

Weight (kg) 0.7

Dimensions (millimeters) 25 (height) × 133 (width) × 210 (length)

Temperature (℃) 100 150 200 250 280

Adiabatic time (minutes) 13 10 9

Insulation box TB2065 (applicable toDP5660Data Collector

Weight (kg) 0.7

Dimensions (mm) 29 (height) × 133 (width) × 210 (length)

Temperature (℃) 100 150 200 250 280

Adiabatic time (minutes) 13 11 10

DP5662(Replace)DQ1862

Data LoggerDP5 DP5562 6Channel USB interface and Bluetooth with optional wireless transmission

Range:-100 ℃ to 1370 ℃ Accuracy: ± 0.5 ℃ Resolution: 0.1 ℃

Maximum operating temperature: 85 ℃ (to ensure measurement accuracy, the recorder will shut down and warn the operator at this temperature)

Sampling interval: adjustable from 0.05 seconds to 10 minutes

Start record: manual, temperature rise, time stop record: manual, temperature fall

Size/Weight: 6 channels20x57x 165mm/Weight 0.3Kg

Storage capacity: 50000 data/channels for storing 10 measurements, charging once, running for 25 hours (1 second sampling), or measuring temperature 20 times

Charging time: 1.5 hours (using a charger) or 14 hours (charging the sampling computer)

Bluetooth: Reset within a 5-meter range/Download and real-time temperature reception

Thermal Barrier TB2028 (applicable to)DP5662Data Collector

Weight (kg) 0.2

Dimensions (millimeters) 24 (height) × 136 (width) × 195 (length)

Temperature (℃) 100 150 200 250 300

Adiabatic time (minutes) 9

→ Insulation box TB2036 (applicable toDP5662)

weight
(kg)

size
(mm)

temperature
(℃)

Adiabatic time
(minutes)

2.25

83 (high)

100

300

127 (width)

200

138

290 (length)

300

78

Insulation box TB2020 (applicable toDP5662Data Collector

Weight (kg) 0.5

Dimensions (mm) 28 (height) x 84 (width) x 233 (length)

Temperature (℃) 100 150 200 250 280

Adiabatic time (minutes) 25 13 10 8 7

Insulation box TB2021 (applicable toDP5662Data Collector

Weight (kg) 0.65

Dimensions (mm) 35 (height) x 84 (width) x 233 (length)

Temperature (℃) 100 150 200 250 280

Adiabatic time (minutes) 36 18 13 11 10

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!