ØThe inner liner of the box is made of high-quality SUS304 stainless steel brushed plate, and the outer shell is made of Baosteel steel plate sprayed with plastic.Customization is also available (the shell is made of high-quality SUS304 stainless steel brushed plate)
ØuniqueBTCBalanced temperature control method, stable and balanced heating capacity, regulating ideal temperature environment, and achieving high-precision and high stability temperature control
ØThe humidification method adoptsExternalquarantineHumidification of steam in boilers;
ØIt has the function of automatically selecting and operating the refrigeration circuit according to the temperature setting value, and the operation is simple
ØThere areHollow special high and low temperature resistant conductive heating glass window,High brightness cold light source PhilipsLighting fixtures that allow for real-time observation of sample conditions
ØControl system: imported high-precision LCD touch instrument,Directly programmable and solidified curvesImport execution of electronic components
ØThe sealing strip inside the box is made of imported silicone rubber that is resistant to high and low temperatures, and has excellent sealing and insulation performance
ØOriginal imported refrigeration system.
ØMobile casters: Wear resistant, silent movement, with braking function.
ØMultiple safety protection devices: protection against overheating, overpressure, phase sequence, motor overheating and overload, etc.
model
|
GDS—010
|
GDS—025
|
GDS—050
|
GDS—100
|
|
Studio size (mm)
|
500×400×500
|
600×600×700
|
800×700×900
|
1000×1000×1000
|
|
Dimensions (mm)
|
980×1020×1650
|
1080×1160×1800
|
1260×1220×1980
|
1480×1550×2200
|
|
technology
require |
temperature range
|
A: -20, B: -40, C: -60, D: -70~100 ℃, 150 ℃, 200 ℃ (optional)
|
|||
temperature fluctuation
|
≤±0.5℃
|
||||
temperature uniformity
|
≤±2℃
|
||||
Humidity range
|
30~98% R•H
|
||||
Humidity deviation |
≤+2-3%RH
|
||||
Heating and cooling rate
|
Heating up ≥ 2-3 ℃/min
|
Cooling rate ≤ 0.7-1 ℃/min
|
|||
Cold and hot
exchange system |
Thermal insulation material
|
Ultra fine glass fiber/hard polyurethane foam
|
|||
Heater
|
Nickel chromium alloy electric heater(Stainless steel finned radiator
|
||||
Humidifier |
The humidification method adopts an external isolated boiler steam humidification method
|
||||
Cooling device
|
Multi stage membrane evaporator(Fin type multi-stage evaporator)
|
||||
air circulation
|
Single cycle, extended shaft, low noise, stainless steel centrifugal fan blades
|
||||
Cooling method
|
Unit cooling method/Dual (stacked) cooling method (air-cooled or water-cooled)
|
||||
compressor
|
French "Taikang" fully enclosed refrigeration compressor
|
||||
control
system |
Control device
|
Korean ternary LCD touch screen instrument, menu mode operation, can be directly programmed and solidified with curves
|
|||
Sensors
|
Imported ultra-fine 3mm PT100 platinum resistor
|
||||
Security device
|
Leakage protection, over temperature protection, fast fuse, compressor overvoltage protection
|
||||
Standard configuration
|
Internal heated insulated glass observation window: one 250 × 300 (mm), one test hole ¢ 50mm, two sample racks, and one lighting lamp
|
||||
Power Supply
|
220V · 50HZ/(380V · 50HZ three-phase four wire system)
|
Always be responsible for the brand and always ensure customer satisfaction! Thank you very much for your trust and support of our company. We make the following commitments:
1We provide product technical solutions to customers before selling the constant temperature and humidity test chamber, and can provide problem-solving methods and technical consulting services according to customer requirements.
2A dedicated customer service center is established, equipped with dedicated technical engineers responsible for pre-sales, in sales, and after-sales service of products, introducing product performance to users,Guide the use and maintenance of the product. combineProvide relevant information, solve difficult problems during use, and be a good user consultant.
3SoldHumidity ChamberEnsure that the work is meticulously crafted in accordance with the contract requirements. And provide customers with complete technical information and corresponding technical training. Professional technicians will be dispatched to install and debug special equipment on site until the user is satisfied.
4Assist users in training instrument and equipment administrators and operators to enable them to use and maintain instruments and equipment correctly, establish regular follow-up and maintenance systems, regularly track and follow up on the quality of products sold, and minimize potential losses caused by user failures;
5SoldHumidity ChamberThe warranty period is twelve months from the date of installation,During the warranty period, if there are quality issues with the product itself, we will provide free repairs to customers.Outside the warranty period, provide maintenance services according to customer needs, and offer discounted factory prices for equipment accessories and vulnerable parts.