Shanghai Xinrui DR6000 series multi parameter water quality analyzer
Usage Overview
This product is a popular instrument specially designed for small and medium-sized enterprises. It has the advantages of complete functionality, simple operation, and high measurement accuracy. Used to determine various parameters such as chemical oxygen demand (COD), ammonia nitrogen, total phosphorus, etc. in surface water, reclaimed water, urban sewage, and industrial wastewater.
Product Features
Adopting imported high-quality integrated chips to ensure that the instrument can work stably for a long time; The standard curve of memory operation can be modified by users themselves, and it has the function of saving in case of power failure;
► Reliable positioning structure and independent dual path system can effectively avoid interference caused by stray light and accurately determine the ion concentration value in the sample;
Equipped with a single button parameter selection function, it can automatically complete the selection of light source, detector, and working curve. High degree of automation and simple operation;
► Cold light source narrowband interference monochromatic light processing system, equipped with customized 100000 hour high-intensity long-life cold light source, no worries about replacement;
The complete set is equipped with a digestion furnace, and the digestion temperature and timing can be set freely. The microcomputer heating and temperature control system has over temperature protection function, which can effectively save energy consumption;
► Independently develop rapid digestion reagents to ensure long-term stable and low-priced supply, effectively reduce user workload and sample testing costs, and comply with national standards.
Technical indicators
*COD determination anti chlorine interference: [CL-]<1000mg>1000mg>
PRODUCT MODEL |
Measurement parameters |
Measurement range |
measuring accuracy |
Measurement time |
DR6000 |
COD、 Total phosphorus, ammonia nitrogen, turbidity |
COD: segmented from 3 to 10000mg/L; Total phosphorus: 0-20mg/L segmented;Ammonia nitrogen: 0-50mg/L segmented; Turbidity: 3-500NTU |
≤±5%~±10% |
1-50 minutes |
DR6000A |
COD、 Ammonia nitrogen |
COD: segmented from 3 to 6000mg/L; Ammonia nitrogen: 0-50mg/L segmented |
≤±5%~±10% |
1-50 minutes |
DR6000B |
COD、 Total phosphorus and ammonia nitrogen |
COD: segmented from 3 to 6000mg/L; Total phosphorus: 0-10mg/L; Ammonia nitrogen: 0-50mg/L |
≤±5%~±10% |
1-50 minutes |
DR6100 |
COD |
Segmented from 5 to 6000mg/L |
≤±5%~±10% |
15-20 minutes |
DR6100A |
COD |
15~1000mg/L |
≤±5%~±10% |
15-20 minutes |
DR6100B |
COD |
Segmented from 15 to 1500mg/L (optional from 3 to 6000mg/L) |
≤±5%~±10% |
15-20 minutes |
DR6200 |
total phosphorus |
Segmented from 0 to 20mg/L |
≤±5% |
35-50 minutes |
DR6200A |
total phosphorus |
0~10mg/L |
≤±5% |
35-50 minutes |
DR6300 |
Ammonia nitrogen |
0.02~50mg/L segmented |
≤±10% |
10-15 minutes |
DR6300A |
Ammonia nitrogen |
0~12mg/L |
≤±10% |
10-15 minutes |
DR6100A |
COD |
Desktop microcomputer, equipped with4 Hole disintegrator, measuring range:15~1000 mg/L |
7800 |
DR6100B |
COD |
Desktop microcomputer, equipped with12 Hole disintegrator, measuring range:15~1500 mg/LSegmented (optional)3~6000mg/L) |
9800 |
DR6100 |
COD |
Desktop microcomputer, equipped with12 Hole disintegrator with printer, measuring range:COD:5~6000 mg/Lsegmentation |
12800 |
DR6100M |
Permanganate index |
Desktop microcomputer, equipped with12 Hole disintegrator with printer,CODMn Measurement range:0.05~50 mg/Lsegmentation |
12800 |
DR6200A |
total phosphorus |
Desktop microcomputer, equipped with12 Hole disintegrator, equipped with printer, measuring range0~10mg/Lsegmentation |
10000 |
DR6200 |
total phosphorus |
Desktop microcomputer, equipped with12 Hole disintegrator, equipped with printer, measuring range0~80mg/Lsegmentation |
12000 |
DR6300A |
Ammonia nitrogen |
Desktop microcomputer, measurement range 0~20mg/L,(Expandable measurement range)) |
4800 |
DR6300 |
Ammonia nitrogen |
Desktop microcomputer, equipped with printer, measuring range0~100mg/Lsegmentation |
6200 |
DR6000A |
CODAmmonia nitrogen |
Desktop microcomputer, equipped with printer, equipped with12 Pore digester, Measurement range:COD:3~6000mg/LAmmonia nitrogen:0~50 mg/L |
14800 |
DR6000B |
CODAmmonia nitrogen, total phosphorus |
Desktop microcomputer, equipped with printer, equipped with12 Pore digester, Measurement range:COD:3~6000mg/LAmmonia nitrogen:0~50 mg/LTotal phosphorus:0~20mg/Lsegmentation |
16800 |
DR6000C |
Ammonia nitrogen, total phosphorus, turbidity, hardness |
Desktop microcomputer with printer and accessories12 Pore digester, measuring range: ammonia nitrogen0~50 mg/LSegmentation; total phosphorus0~20 mg/LSegmentation; Turbidity:3~500 NTUSegmentation; Total hardness:0-6mg/l |
17800 |
DR6000 |
CODAmmonia nitrogen, total phosphorus, turbidity |
Desktop microcomputer with printer and accessories12 Hole disintegrator, measuring range:COD:3~10000 mg/LSegmentation; Ammonia nitrogen0~50 mg/L Segmentation; total phosphorus0~20 mg/LSegmentation; Turbidity:3~500 NTUSegmentation; |
22200 |