RJ-V5Execution standards:
GB/T50081-2002Standard for Testing Methods of Mechanical Properties of Ordinary Concrete
GB/T50082-2009Long term Performance and Durability Testing of Ordinary Concrete
Method Standards
JGJ55-2000Design Specification for Ordinary Concrete Mix Proportion
JTJ053-4Test Code for Cement Concrete in Highway Engineering
JTGE30-2005Test Code for Cement and Cement Concrete in Highway Engineering
National Electric Power Industry StandardsDL/T5150-2001Test Code for Hydraulic Concrete
SL352-2006Test Code for Hydraulic Concrete
JG/243-2009Concrete frost resistance test equipment
JGJ/T193-2009Standard for Durability Testing and Evaluation of Concrete
AmericaASTM/C666Standard Test Method for Rapid Freeze Thaw Capacity of Concrete
Product Overview:
RJ-V5The concrete rapid freeze-thaw testing machine adopts the water freeze-thaw method, which meets the appearance requirements100*100*400The freeze-thaw resistance test of concrete specimens can be placed once5Group(16The piece contains a central specimen. During the experiment, the test piece is placed in a test rubber cylinder, which is filled with water. The rubber cylinder is then placed in a test piece box containing antifreeze, and the unit's cooling or heating of the antifreeze is used to freeze or melt the test piece in the rubber cylinder, thus completing the freeze-thaw test.
The device operates fully automatically throughout the entire process, without the need for human intervention. When the experiment is completed to the set point (default)50After a certain number of times, the machine will automatically stop and emit a prompt sound to indicate the completion of the test. If the test needs to continue, the set number of times can be accumulated and the machine will continue to run.
characteristic:
characteristic1The compressor has low power,3PImported compression refrigeration. Whether placed indoors or not Still outdoors, with low noise.
2Heating does not use heating tubes and has low power. The heating tube is soaked in antifreeze for a long time, which is prone to conductivity and other phenomena, affecting the heating life.
3Integrated machine, easy to move in the laboratory.
4environment protection Low noise and energy-saving. The body is compact and does not take up much space.
Experimental parameters:
Freeze thaw cycle period 2.5~4Hours, melting time not less than1/4Freeze thaw cycle, center temperature of the specimen at the end of freezing-18±2℃Melting, the center temperature of the specimen at the end of melting5±2℃Cooling time1.5-2.5Hour, heating time1.0-1.5Hour, the temperature difference between the center and surface of the specimen is less than28℃The standard for the number of cycles is300Multiple times.
Technical parameters and product configuration:
RJ-V5Technical parameters: |
RJ-V5Product configuration: |
|
◆rated voltage:AC380V/20AThree-phase four-wire ◆Whole machine power:3KW ◆Power:3KW ◆Cooling Power:3KW ◆Measurement accuracy:±0.5℃ ◆Display resolution:0.06℃ ◆Maximum specimen capacity:5group+1A central specimen (In total)16Individual test piece ◆temperature range:-25℃~25 ℃ (user adjustable) ◆Temperature uniformity:Between each point<2℃ ◆Size of concrete test block:100*100*400 mm ◆Rubber bucket size:120*120*500 mm ◆Working Size:545*545*650(mm) ◆External dimensions:1700*800*1000mm ◆Instrument weight:make an appointment200kg |
◆RJ-V5Type freeze-thaw host:1tower ◆ Antifreeze solution:28kilogram (Use redeemable)50%Tap water) ◆ Test piece rack:1individual ◆ Rubber bucket:16individual ◆18B20Sensor:5Root (one of which is a backup) ◆ Serial port cable:1strip ◆ Software CD:1fix ◆ Instruction manual and warranty card:1share ◆ Fangzheng CommercialPCcomputer:1Platform (optional for users) ◆DT-W18Dynamometer:1Platform (optional for users)
|