The Labonce CGS series comprehensive drug stability test box adopts a structural design and uses high-quality imported components, suitable for long-term continuous operation, with stable and reliable performance, and suitable for GMP certified users.
1. The adopted air duct system design ensures good temperature and humidity uniformity at different positions inside the box, combined with a lighting system;
2. European original imported fully enclosed industrial compressor, high efficiency, low noise, ensuring long-term continuous operation of the equipment;
3. European imported temperature and humidity integrated sensor with high sensitivity, directly detecting humidity without maintenance;
4. Imported temperature and humidity controller, fast sensing, small system error;
5. The inner liner is made of fully mirrored stainless steel 304, which is pollution-free and easy to clean;
6. Equipped with an alarm system that meets GMP requirements, possessingA data collection system that meets GMP requirements;
7. Meets ICH2003 Q1A (R2), CP2010, and follows the standard GB/T 10586-2006;
parameter
| name | Drug Stability Test Chamber (Comprehensive) | Drug Stability Test Chamber (Comprehensive) | ||
| model | Labonce-120CGS | Labonce-250CGS | Labonce-380CGS | Labonce-500CGS |
| Temperature control range | 10-65 ℃ (15-65 ℃ when illuminated) | 10-65 ℃ (15-65 ℃ when illuminated) | ||
| Temperature control fluctuation | ±0.5℃ | ±0.5℃ | ||
| temperature deviation | ±2.0℃ | ±2.0℃ | ||
| Moisture control range | 40~95%RH | 40~95%RH | ||
| Humidity fluctuation | ±3%RH | ±3%RH | ||
| Humidity deviation | ±5%RH | ±5%RH | ||
| Range of illumination | 0~8000LUX | 0~8000LUX | ||
| Illuminance deviation | ±500LUX | ±500LUX | ||
| Temperature and humidity control method | Balanced temperature and humidity control method | Balanced temperature and humidity control method | ||
| refrigeration system | Imported fully enclosed compressor | Imported fully enclosed compressor | ||
| Temperature and humidity sensor | Imported capacitive temperature and humidity sensor | Imported capacitive temperature and humidity sensor | ||
| controller | Imported temperature and humidity controller | Imported temperature and humidity controller | ||
| Data printing | Needle micro printer | |||
| data backup | USB storage | |||
| test point | 40℃ 75%RH、 25℃ 60%RH | |||
| dual protection | Independent over temperature protection system | |||
| Working environment temperature | +5~35℃ | |||
| inner material | Mirror stainless steel 304 | |||
| Shell material | Steel plate spray coating | |||
| water tank | External water tank | |||
| power supply | AC 220V±10% 50HZ | |||
| safety device | Compressor overheating, fan overheating, over temperature, compressor overpressure, overload, water shortage protection | |||
| Zui High Power (kW) | 1.5 | 2.5 | 2.5 | 3 |
| Volume (L) | 150 | 250 | 380 | 500 |
| Internal dimensions (mm) | 600×405×620 | 600×500×830 | 680×600×930 | 800×700×900 |
| W×D×H | ||||
| Dimensions (mm) | 760×830×1480 | 760×940×1650 | 840×970×1750 | 1080×1180×1850 |
| W×D×H | ||||
| Shelf (standard) | 3 | 3 | 3 | 4 |
| Note 1 | Specially suitable for strong light, high temperature, and high humidity tests in influencing factor experiments | |||
