Color Eye 7000A spectrophotometer ensures absolutely accurate color measurement
On the basis of X-Rite's Color Eye 7000, the most advanced precision measuring instrument in this industry, the Color Eye 7000A integrates several automatic functions to make operations more efficient. The optical design of Color Eye 7000A is identical to that of Color Eye 7000, ensuring that both instruments produce the same measurement data. The Color Eye 7000A boasts excellent instrument to instrument consistency, exceptional precision, and significant repeatability. Whether in the factory or in the laboratory, Color Eye 7000A is your best choice for precision color analysis.
Accurate and reproducible measurements enable you to separate data globally
With Color Eye 7000A, you only need to measure the sample once to store it as a completely reliable digital standard. By separating product color numbers according to the standard, if the product meets the manufacturer's shipping color inspection, it will definitely meet the customer's purchasing standard inspection.
Dual beam design, featuring two spectral analyzers, has super stability and higher production efficiency. |
Mechanized UV control enhances efficacy
Through a mechanized UV control device, the content of ultraviolet light can be automatically adjusted to natural D65 sunlight. In addition, the Color Eye 7000A also includes two user programmed adjustments. The mechanized mirror reflection device allows you to easily change settings and quickly measure color drift caused by surface gloss or material texture.
Touchscreen display makes it easy for you to observe and change the instrument status
The unique touch screen display allows you to have a clear understanding of the instrument status, making it more flexible to change instrument settings. When using Color i Match color formula or quality management software together, you can also choose to have the autonomy to change the instrument status from the instrument or software.
Accurately measure transparent and semi transparent substances
By using a movable template holder, it is possible to accurately read the scattering data of the template (including the film) or directly transmit the data. By using Color Eye 7000A and X-Rite's ProPaletter color formula software, you can achieve accurate color matching at any level of coverage.
The wide and unobstructed transmission space makes it easy to manipulate the transmission sample to obtain the most accurate measurement results. |
The true dual beam design provides higher consistency and productivity
The Color Eye 7000A has two spectral analyzers that can simultaneously measure color samples and internal parameters with one flash (or multiple flashes if needed). This advanced design not only ensures long-term stability, but also enables faster reading of high traffic data.
Pulse xenon light source ensures measurement accuracy
The high-intensity pulsed xenon ensures accurate readings. Even for dark or highly saturated colors, it is no exception. The high signal-to-noise ratio reduces the influence of surrounding light, the short D65 flash time extends the lifespan of the instrument, and produces almost no heat, so there is no need to preheat the instrument.
The unique automatic electronic balancer provides reliability
This unique X-Rite feature uses an additional pulsed xenon light source that can automatically flash at predetermined intervals to balance the two spectrometers. This continuous and frequent adjustment can compensate for temperature changes, power fluctuations, and prevent electron drift.
specifications
Repeatability (whiteboard) |
0.01RMS△E CIE Lab |
|
Instrument to Instrument Consistency (LAV) |
0.08 Mean CIE Lab |
|
lighting |
Pulsed xenon |
|
Flash frequency/measurement (normal use) |
1 |
|
Time |
<1 second |
|
spectral range |
360nm to 700nm |
|
wavelength accuracy |
0.1nm (400 to 700nm) |
|
wavelength accuracy |
0.05nm (400 to 700nm) |
|
wavelength interval |
10nm |
|
band pass |
10nm |
|
Photometric range |
0%-200% |
|
Photometric resolution |
0.001% |
|
measuring aperture |
|
|
Large Measurement Aperture (LAV) |
1 inch (2.54 centimeters) |
|
Medium Measurement Aperture (MAV) |
0.6 inches (1.5 centimeters) |
|
Small Measurement Aperture (SAV) |
0.3 * 0.4 inches (0.75 * 1 centimeter) |
|
Ultra small measurement aperture (VSAV) |
0.12 * 0.31 inches (0.3 * 0.8 centimeters) |
|
Optical settings |
Scattering/8 ° (illumination measurement) |
|
transmission |
Direct and Scattering |
|
External dimensions |
15.25 inches high, 11 inches wide, 28 inches |
|
operate temperature |
Fahrenheit 60 ° -90 ° (non condensing environment) |
|
Power consumption |
36 watts when not in operation, 100 watts when used continuously |
|
Power supply requirements |
117V AC/50-60Hz |
Beijing (Headquarters)
Address: Century Economic and Trade Building, No. 72 West Third Ring North Road, Haidian District
Room 2610, Building A 100048
Phone:
Fax:
Email: info@chinacoat.com.cn
Guangzhou
Address: Room 705, No. 552 Fangcun Avenue Middle, Liwan District 510360
Telephone:
mobile phone:
Chongqing
Address: Room 1403, Building 18, No. 168 Caiyuan Road, Yuzhong District
Telephone:
mobile phone:
Shanghai
Address: 1st Floor, No. 9, Lane 88, Kaixuan Road, Changning District, 200042
Telephone:
mobile phone: