1、 Overview: The control box is used to collect operational data from downstream collection instruments and valves, and is connected to data terminals
Product details

1、 Overview:

Collect operational data of instruments and valves in the downstream of the control box, connect data terminals in the upstream, and also configureCommunication interfaces such as USB and RS232 have functions of data acquisition, storage, local communication, and remote upload. LCD touch screens can be equipped as needed to achieve local display query and debugging functions.

Communication between the collection control box and the instrument can be selected according to needsM-bus and RS485 bus forms, simple construction; The data collection control box and management center data terminal adopt GPRS wireless public network communication, which is convenient and stable. As needed, the collector can also achieve Internet public network communication and support TCP/IP network protocol.

The collector can also be used as a relay in the system to expand the device's load capacity, expand access to system user meters and devices, and flexibly meet system requirements.

The product meets the technical standards:

Technical Regulations for Heating MeteringJGJ173-2009

Energy saving Design Standards for Public BuildingsDB11/687-2009

Energy saving Design Standards for Residential Buildings in Severe Cold and Cold RegionsJGJ26-2010

Design Standard for Energy Efficiency of Residential BuildingsDBJ 11 - 602 - 2006

Technical Regulations for Energy saving Renovation of Existing Residential BuildingsDB11/381-2016

Thermal metering device using on-off time area methodQ/FSJYS 0002-2013

IIProduct Features:

l Integrating metering, control, billing, and remote monitoring;

l Integrating multiple communication methods such as wireless, bus, and public network, the system network is flexible and reliable;

l Software modular design, independent functions, easy to expand, flexible and convenient networking, easy to upgrade, and convenient for system implementation;

l Open interface that can coordinate with other intelligent systems, share data, and control linkage; Convenient on-site testing for personnel.

l Powerful data processing and mining techniques provide safe and reliable operational data for heating operations, improving the level of heating management;

l Read data at regular intervals or according to superior commands and issue real-time superior control commands;

l Equipped with real-time clock function and integrated high-precision clock chip, it can achieve hourly reading function.

l Built in wirelessGPRSCommunication module, realizing wireless remote transmission of data to meet the management needs of the system;

l Capable of managing relay automatic networking (forming a base station relay network) communication, effectively expanding network coverage;

l Equipped with breakpoint resume function, it can be powered on again after power failure without affecting data information;

l Equipped with data storage and redundancy functions, capable of recording no less than90Historical data of days and can be queried based on dates;

l The product has indicator lights for power, network, operation, and protection, allowing users to have a clear understanding of the device's working status.

3、 Technical parameters:

Category function On-off time area method Integrated temperature control Calorimeter method
JYCJK-T JYCJK-K JYCJK-H
power supply AC220V ± 20%/50Hz (optional with UPS power supply to meet the working needs of the acquisition calculator in case of power failure)
Working Voltage 12V - 24V
display mode You can choose to configure a large touch screen for on-site display, or reserve a display interface for external display on a mobile computer or handheld device;
data collection According to the set data collection cycle, automatically collect all real-time data information from the building's heat meter and user on/off controller
data processing It can achieve heat allocation and storage within the collection calculator, without relying on the upper computer for calculation and storage functions.
device power consumption Maximum operating current<100mA, average power consumption<20W, static power consumption ≤ 0.5W
Protection level IP54
Communication Type M-bus bus, RS485 bus
Open interface M-bus interface, RS485 interface, USB interface, 232 interface, Internet network interface, etc
Installation location Ventilated and dry, with high GPRS signal strength and easy wiring (network transmission can also be used, IP address and line need to be provided).
working environment Environmental temperature: (-10~55) ℃; Relative humidity:<80% RH

4、 Installation size

Box size: Length*Width * Height(Unit)mm)320*120*400