BritainMICHELLProduced by the company; do120Measurement basis of standard laboratories in multiple countries; Good repeatability, fast response speed, easy operation, and convenient portability!
overview
The MCH-S8000S cold mirror high-precision SF6 dew point meter is an outstanding representative in the field of gas dew point detection, produced by the British company Michell. A laboratory measurement standard dew point meter designed specifically for university laboratories, factory metrology centers, scientific research institutes, and national metrology institutions! At present, the National Institute of Metrology, Shanghai, Guangdong, Liaoning, Shaanxi, Xinjiang, Shenzhen, Foshan, Chinese Academy of Sciences and other provincial and municipal metrology institutions all use the MCH-S8000S cold mirror dew point meter as the measurement standard for temperature and humidity dew point!
The MCH-S8000S dew point meter has a wide range and fast response speed. Its unique frost point confirmation system completely eliminates the problem of supercooled water interference, as well as many other improvements, such as simple mirror cleaning, multilingual display, horizontal and vertical appearance, and so on.
On the basis of excellent traditional design products with the highest measurement performance and reliability, the MCH-S8000S provides unparalleled measurement accuracy for dew point measurements of air and other substances. The core of the product is a sensor probe with advanced optical path system, which has excellent measurement sensitivity and accuracy. The new sensor probe has the feature of built-in compensation for sample gas temperature and ensures that the mirror surface is easy to clean and monitor. Secondly, the "integration" concept of MCH-S8000S makes it a complete humidity meter, with two product placement options: vertical (laboratory version) and horizontal (industrial field version).
The MICHELL S8000S cold mirror high-precision dew point meter is a newly developed product by the British company Michell; Its basic and automatic cold mirror dew point principle provides high-precision and drift free reliable measurement for industrial processes and calibration applications.

Gases with different moisture contents will condense on the mirror surface at different temperatures. Using photoelectric detection technology to detect the exposed layer and measure the temperature during condensation, directly displaying the dew point. The methods of mirror cooling include semiconductor cooling, liquid nitrogen cooling, and high-pressure air cooling. The cold mirror dew point meter adopts a direct measurement method, which can be used as a standard dew point meter while ensuring accurate dew detection, high efficiency of mirror cooling, and precise measurement of condensation temperature. At present, the international high-precision reaches ± 0.1 ℃ (dew point temperature), and a certain gas humidity corresponds to one dew point temperature; A dew point temperature corresponds to a certain gas humidity. Therefore, measuring the dew point temperature of a gas can determine its humidity. The absolute humidity can be obtained from the dew point, and the relative humidity of the gas can be obtained from the dew point and the temperature of the measured gas. The value directly given by the dew point meter is the dew point temperature, specifically the "thermodynamic dew point temperature". The definition adopted by the World Meteorological Organization is the thermodynamic dew point temperature Td of moist air with a pressure of P and a mixing ratio of r, which refers to the temperature at which moist air is saturated with water at a given pressure.

At this temperature, the saturated mixing ratio rw of humid air is equal to the given mixing ratio r. The working principle of a photoelectric dew point meter can be simply described as follows: the measured gas passes over a smooth metal mirror surface cooled by cold nitrogen gas at a certain flow rate under constant pressure. As the temperature gradually decreases, the mirror surface begins to condense (or frost) when it reaches a certain temperature, and the temperature of the mirror surface at this time is the dew point temperature. The instrument measures the dew point temperature Td through an optical system, temperature measurement circuit, logic control circuit, digital display circuit, etc., and displays it. At present, the National Institute of Metrology, Shanghai, Guangdong, Liaoning, Shaanxi, Xinjiang, Shenzhen, Foshan, Chinese Academy of Sciences and other provincial and municipal metrology institutions all use Michell cold mirror dew point meters as the measurement standard for temperature and humidity dew point!

Product Application
A. Laboratory reference standards;
B. High voltage switch on-site micro water detection;
C. Monitoring of key points in other industrial gas processes;
F. A laboratory measurement standard dew point meter designed specifically for university laboratories, factory metrology centers, scientific research institutes, and national metrology institutions.
Functional Features
A. Global leading technology;The use of a dual light path system has excellent sensitivity and automatic compensation for changing gas temperatures;
B.The sensor room with hinges makes it very easy to monitor and clean the mirror surface;
C.Multiple units display: ℃ dp; ℉ dp; ppm (v); %rh;
D.Rapid measurement response at 2 ℃/sec;
E.The maximum pressure tolerance is 20 bara;
F.Collect data on humidity, pressure, and flow rate through SD card and USB interface;
G。High resolution LCD screen, easy to operate menu structure;
H. Multiple languages available;
I. The mirror is made of gold-plated brass material;
J. When purchasing, an endoscope can be selected to easily observe the formation of frost/dew on the mirror surface.
Technical parameters
|
project |
TECHNICAL INDEX |
|
Detection range |
-60℃…+40℃dp |
|
unit Display and/or output |
℃dp;℉dp;ppm(v);ppm(w)/SF6;%rh;g/kg;g/m3 Traffic:ml/min Pressure:kpa;bara;psia |
|
accuracy |
Humidity: ±0.1℃dp |
|
Temperature: ±0.1℃ |
|
|
resolution |
0.001℃dp |
|
repeatability |
0.01℃dp |
|
temperature measurement |
4linePRTOr externalPt100measure |
|
Auxiliary cooling |
NOT REQUIRED |
|
measuring pressure |
0…20Bara |
|
sample flow |
0.01…1.0l/min |
|
Built in flow meter |
flow sensor |
|
Output |
4…20mA,0…20mA,0…1V,USB |
|
data acquisition |
arriveSDCard or throughUSBApplication software for interfaces |
|
Display mode |
LCDhigh resolution |
|
operation temperature |
-20℃…+50 ℃ |
|
storage temperature |
-40℃…+70 ℃ |
|
atmospheric pressure |
86kPa~106kPa |
|
Specification and size |
330×180×410mm |
|
Instrument weight |
15.0Kg |
|
Power specifications |
85…264VAC,50/60Hz;100VA |
*Measurement accuracy refers to the maximum deviation between the instrument to be tested and the corrected standard. This parameter must take into account the uncertainty brought by the verification system, as well as the impact of environmental factors during testing or use.
Service guarantee
A. Provide on-site training guidance and conduct on-site demonstration operations.
B. Provide detailed user manuals in both Chinese and English.
C. One year free warranty, lifetime spare parts support and maintenance.
D. The hotline is available 24/7 to answer user inquiries.