Description:
SP-LDE series clamp purified water flowmeter, sanitary purified water pipeline flowmeterIts all Chinese electromagnetic converter core adopts a high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable. The converter circuit design adopts international advanced technology, with an input impedance of up to 1015 ohms, a common mode rejection ratio of better than 100db, and a suppression ability of better than 90db for external interference and 60Hz/50Hz interference. It can measure fluid medium flow rates with lower conductivity. The sensor adopts non-uniform magnetic field technology and a special magnetic circuit structure, which makes the magnetic field stable and reliable, and greatly reduces the volume, reduces repetition, and makes the flowmeter small and flow oriented.
How to choose protection level
According to the national standard GB4208-84 and the International Electrotechnical Commission standard IEC529-76 regarding the protection level of enclosures, the standard is:
IP65: Anti spray type, allowing the faucet to spray water on the sensor from any direction, with a spray pressure of 30KPa, a water output of 12.5L/s, and a distance of 3 meters.
IP68: Submersible type, capable of long-term operation in water.
The protection level should be selected according to the actual situation. The sensor should be installed below the ground. If it is frequently flooded, IP68 should be selected. When the sensor is installed on the ground, IP65 should be selected
Working principle
SP-LDE series clamp purified water flowmeter, sanitary purified water pipeline flowmeterBased on Faraday's law of electromagnetic induction. The measuring tube of the flowmeter is a non-magnetic alloy short tube lined with insulating material. Two electrodes are fixed on the measuring tube by passing through the tube wall along the diameter direction. The electrode tip is basically flush with the inner surface of the lining. When the excitation coil is excited by two pulse waves, a working magnetic field with a magnetic flux density of B will be generated in the direction perpendicular to the axis of the measuring tube. At this point, if a fluid with a certain conductivity flows through the measuring tube. Induce an electromotive force E by cutting the magnetic field lines. The electromotive force E is proportional to the magnetic flux density B. Measure the product of the inner diameter d of the tube and the average flow velocity v. The electromotive force E (flow signal) is detected by the electrode and sent to the converter through a cable. After amplifying and processing the flow signal, the converter can display the fluid flow rate and output signals such as pulses and analog currents for flow control and regulation.
How to choose additional features
The basic model comes with display, 4-20mA output, and 0-1kHz alarm functions. Other additional functions can be added according to the actual situation.
Split installation: If the sensor needs to be installed below the ground or for other reasons, a split installation method should be selected.
RS-485 communication: If communication between sensors and other devices is required, RS-485 communication function should be selected.
Clamp purified water flow meter, sanitary purified water pipeline flow meterTechnical selection:
|
Anti lightning function |
Adopting lightning protection design circuit, efficient anti-interference circuit, suitable for various harsh environments |
|
Sensor zero point correction and automatic zero calibration |
Refer to the operating instructions |
|
Fault self diagnosis function and alarm prompt |
Can accurately detect faults in sensor excitation circuits, electrode signal circuits, converters, etc. and display alarms; , amp; , amp; , amp; , amp; , lt;, /o:p> |
|
Empty and full tube detection function |
Empty full tube detection technology using capacitive technology |
|
Bi directional measurement function for instantaneous flow and cumulative flow |
Accurate measurement of both forward and reverse flow rates |
|
The function of online adjustment of flow direction |
Refer to the operating instructions |
|
Multiple flow units to choose from |
m3/h,l/h,kg/h,t/h,m3/m.l/m, |
|
Damping time setting function |
Refer to the operating instructions |
|
Small signal cutoff function |
Refer to the operating instructions |
|
Multiple output modes |
16 bit digital current loop 4-20mA output, 0-5KHz frequency output, pulse equivalent output |
|
Online output calibration function |
Refer to the operating instructions |
|
Accumulated amount reset function |
Refer to the operating instructions |
|
Cumulative pre-set function |
Refer to the operating instructions |
|
Multiple excitation frequency setting functions |
6.25 Hz、12.5 Hz、25Hz |
|
Wide range power mode |
DC: 18V~36V and AC: 85V~265V |

Clamp purified water flowmeter, sanitary purified water pipeline flowmeter product spectrum
| model | caliber | |||||
| SP-LDE | 15~2600 | |||||
| code | Electrode material | |||||
| K1 | 316L | |||||
| K2 | HB | |||||
| K3 | HC | |||||
| K4 | titanium | |||||
| K5 | tantalum | |||||
| K6 | platinum alloy | |||||
| K7 | Stainless steel coated with tungsten carbide | |||||
| code | Lining material | |||||
| C1 | Polytetrafluoroethylene (F4) | |||||
| C2 | Perfluoroethylene propylene (F46) | |||||
| C3 | Polyfluoroethylene (FS) | |||||
| C4 | Polyvinyl rubber | |||||
| C5 | polyurethane rubber | |||||
| code | function | |||||
| E1 | Level 0.3 | |||||
| E2 | Level 0.5 | |||||
| E3 | Level 1 | |||||
| F1 | 4-20Madc, Load ≤ 750 Ω | |||||
| F2 | 0-3kHz, 5V active, variable pulse width, output high-end effective frequency | |||||
| F3 | RS485 interface | |||||
| T1 | Normal temperature type | |||||
| T2 | High temperature type | |||||
| T3 | Ultra high temperature type | |||||
| P1 | 1.0MPa | |||||
| P2 | 1.6MPa | |||||
| P3 | 4.0MPa | |||||
| P4 | 16MPa | |||||
| D1 | 220VAC±10% | |||||
| D2 | 24VDC±10% | |||||
| J1 | Integrated structure | |||||
| J2 | Split type structure | |||||
| J3 | Explosion proof integrated structure | |||||