Chemical Oxygen Demand COD/Acidity pH Multi parameter TesterIntroduction:
A new measurement mode combining a single acidity electrode channel and a five channel optical system, optimized by combining electrochemical and optical colorimetric methods. Added electrode method for acidity determination, measuring 77 water quality parameters for 50 items, which can achieve:
Bromine Br, iodine, phosphorus P, copper Cu, iron Fe, calcium Ca, magnesium Mg, manganese Mn, aluminum AI, nickel Ni, molybdenum Mo, potassium K, silver Ag, zinc Zn, alkalinity, residual chlorine [free chlorine], total chlorine, ammonia nitrogen, total nitrogen N, total phosphorus P, hydrazine N2H4, ozone O3, acidity pH, chloride, cyanuric acid, fluoride, total hardness, calcium hardness, magnesium hardness, dissolved oxygen O2, deoxidizer, hexavalent chromium Cr, phosphate, sulfate, nitrate [nitrogen], chlorine dioxide, silicon dioxide, platinum cobalt chromaticity, nitrite [nitrogen], chemical oxygen demand COD, anionic surfactant SDBS, absorbance [Abs] and other water quality indicators are quickly and accurately measured. The sentence is:.
The multi parameter photometer adopts a carefully designed optical system, using LED, narrowband interference filter, focusing lens, and silicon photodetector and reference detector for absorbance measurement to maintain the light source and ensure accurate and reproducible photometric readings every time.
Digital acidity pH electrode input, with a built-in microchip inside the probe that can store all calibration information. Store calibration information in the digital acidity pH electrode, so there is no need to recalibrate. The built-in temperature sensor can quickly and accurately measure temperature and perform automatic temperature compensation quickly.
Large capacity data storage, capable of storing up to 1000 readings, providing two USB ports for transferring data to flash drives or computers, and serving as a power source for the instrument host. In order to increase convenience and portability, the measuring instrument is equipped with a built-in 3.7 VDC rechargeable lithium battery, which facilitates users to quickly conduct measurements on site.
Chemical Oxygen Demand COD/Acidity pH Multi parameter TesterParameters:
High quality LED light source system Compared with traditional tungsten lamps and other light sources, LED light sources have superior performance and higher luminous efficiency, and can provide good and stable light sources with less energy. LEDs can ignore the heat generated by themselves, as higher heat can affect the stability of electronic products. |
|
|
High quality optical filter 8 nm narrowband interference filter, accurate to ± 1 nm, with a 25% increase in absorbance. The improved optical filter ensures higher wavelength accuracy and allows for brighter, stronger signals to be received, higher measurement stability, and less wavelength error, ensuring measurement accuracy and precision. | ||
Reference Detector The internal reference system can compensate for any drift caused by battery voltage fluctuations or environmental temperature changes. By automatically adjusting the voltage of the LED, stable light source output can be achieved, enabling fast and stable readings between blank (zero) measurements and sample measurements. | ||
Stable and efficient light source setting High quality concave focusing lenses can collect all the light transmitted through the glass cuvette, reducing errors caused by defects and scratches in the glass cuvette, and minimizing errors and reading deviations caused by defects in the glass cuvette. | ||
CAL Check ™ Function Hanna's Carefully Designed CAL Check ™ Function, allowing the use of NIST traceable standards for instrument performance validation and calibration; CAL Check ™ NIST curve calibration group is used to simulate specific absorbance values for each wavelength to verify the accuracy of subsequent readings. CAL Check ™ The CAL check screen guides the user through the verification process and user calibration step by step. |