The elastic body of the flat sanitary clamp pressure sensor adopts imported materials, diaphragm isolation technology, and the test head has no pressure hole, so there is no viscous medium blockage during the measurement process.
This type of sensor is commonly referred to as: flat membrane pressure sensor, diaphragm type pressure transmitter, food pressure sensor, food pressure transmitter, diaphragm pressure sensor, diaphragm pressure transmitter, sanitary pressure sensor, sanitary pressure transmitter.
◆ Technical parameters
Range:-0.1-10,20,35,70,100,400KPa,1~7MPa
Comprehensive accuracy:0.2%FS、0.5%FS
Output signal:4-20mA (two-wire system), 0-5/1-5/0-10VDC (three wire system)
Supply voltage:24VDC(10-30VDC)
Medium temperature:-20~65℃
Environmental temperature: normal temperature(-20~65℃)
Load resistance: Current output type: Maximum800Ω; Voltage output type: greater than 50K Ω
Insulation resistance: greater than2000MΩ (100VDC )
Sealing grade:IP65
Long term stability performance:0.1% FS/year
Vibration impact: at the mechanical vibration frequencyWithin 20Hz to 1000Hz, the output variation is less than 0.1% FS
Electrical interface: Husman connector
Mechanical connection:2 "clamp type connection
◆ Product dimension diagram:

On site installation diagram of digital graphics card clamp pressure transmitter product:
Product Selection
CTS622 |
Clamp sanitary flat membrane pressure transmitter |
||||||
|
pressure type |
Gauge pressure(GNot labeled); Absolute pressure(A) |
|||||
|
measure Cheng |
measuring range |
|||||
|
(0~ X KpaperhapsMpa) |
||||||
|
|
code |
Comprehensive accuracy (linear)+repeatability+Delay) |
||||
|
1 |
±0.5%FS |
|||||
|
2 |
±0.25%FS |
|||||
|
3 |
±0.1%FS |
|||||
|
take the place of name |
letter name transport go out |
|||||
|
A1 |
4~20mA |
|||||
|
V1 |
1~5V DC |
|||||
|
V2 |
0~5V DC |
|||||
|
V3 |
0.5~4.5V |
|||||
|
DC |
code |
|||||
|
additional function |
F1M30x1.5 |
|||||
|
External thread |
F2 |
|||||
|
Clamp type |
F0 |
|||||
|
special |
W1Cable type(IP67,2m |
|||||
|
) |
W2Socket type(IP65,DIN43650 |
|||||
|
) |
EIntrinsic safety explosion-proof type |
|||||
|
|
||||||
Ex iaIICT5CTS622(0~100KPa)—1 —A1 |
- F1-W1 clamp
Sanitary flat membrane pressure transmitter
Selection Tips:
1. The tested medium should be compatible with the material in contact with the product,
2. Select the additional function code "E" intrinsically safe explosion-proof Ex iaIICT5, which must be powered by a safety barrier.