CPT2000-VOC gas alarm
CPT2000-VOC Gas Alarm Beidou Satellite InstrumentCommon infrared gas transmitters
Electrochemical gas transmitter
name |
name |
range |
repeat accuracy |
specifications |
Conditions of Use |
other |
|
methane |
CH4 |
500-10000ppm |
£ ±3%F |
2312-ADS11 |
-10℃-40℃; 17-65%RH; |
Methane, butane, natural gas. Anti alcohol natural gas/methane |
R600A refrigerant leakage alarm |
methane |
CH4 |
500-10000ppm |
£ ±3%F |
2312-ADS11TH |
-20℃-85℃; 1-99%RH |
Methane, butane, natural gas. Anti alcohol |
|
methane |
CH4 |
500-10000ppm |
£ ±3%F |
2312-ADS11THP |
-20℃-85℃; 1-99%RH; 0.34-2.04atm; |
Methane, butane, natural gas. Anti alcohol |
|
propane |
C3H8 |
500-10000ppm |
£ ±3%F |
2312-ADE13A |
-10℃-40℃;30-70%RH |
Liquefied gas, oil mist/Oil and gasHydrogen gas, LP-Gas/Propane |
|
propane |
C3H8 |
500-10000ppm |
£ ±3%F |
2312-ADE16A-T200 |
-10℃-200℃; 30-70%RH |
Liquefied gas, oil mist/Oil and gasHydrogen gas, LP-Gas/Propane |
|
Organic gas |
VOC |
500-10000ppm; |
£ ±2%F |
2312-ADE16 |
-10℃-200℃; 0-95%RH |
Various low molecular weight organic compounds, including hydrogen and carbon monoxide |
|
Organic gas |
VOC |
500-10000ppm; |
£ ±2%F |
2312-ADE16 |
-10℃-200℃; 0-95%RH |
T200E1m.Various low molecular weight organic compounds, including hydrogen and carbon monoxide; Equipped with a 1-meter extension pipe for air cooling; |
|
Organic gas |
VOC |
0~100%LEL; 0-5%CH4 |
£ ±2%F |
2410-4R |
-10℃-50℃; 0-95%RH |
Various low molecular weight organic compounds, including hydrogen and carbon monoxide |
|
Organic gas |
VOC |
0~100%LEL; 0-5%CH4 |
£ ±2%F |
2410T-4R |
-10℃-50℃; 0-95%RH |
Various low molecular weight organic compounds, including hydrogen and carbon monoxide |
|
Organic gas |
VOC |
0~100%LEL; 0-5%CH4 |
£ ±2%F |
2410TH-4R |
-10℃-50℃; 0-95%RH |
Various low molecular weight organic compounds, including hydrogen and carbon monoxide |
|
Organic gas |
VOC |
0~100%LEL; 0-5%CH4 |
£ ±2%F |
2410THP-4R |
-10℃-50℃; 0-95%RH; 0.34-2.04atm; |
Various low molecular weight organic compounds, including hydrogen and carbon monoxide |
|
Organic gas |
VOC |
0~100%LEL; 0-5%CH4 |
£ ±2%F |
2410TP-4R |
-10℃-50℃; 0-95%RH; 0.34-2.04atm; |
Various low molecular weight organic compounds, including hydrogen and carbon monoxide |
|
Organic gas |
VOC |
50-5000ppm |
£ ±5%F |
2312-ADS20A |
-10℃-40℃; 35-100%RH; |
Alcohols, toluene, xylene, carbon monoxide, various organic gases |
|
Organic gas |
VOC |
50-5000ppm |
£ ±30%F |
2312-ADE22 |
10℃-50℃;10-100%RH |
Ketones, alcohols, benzene, hydrocarbons, hexane, butane, carbon monoxide, methane |
|
Organic gas |
VOC |
50-5000ppm |
£ ±3%F |
2312-ADE23T |
-20℃-200℃; 35-100%RH Flange Jointing |
Alcohols, toluene, xylene, carbon monoxide; Equipped with a 1-meter extension pipe for air cooling; |
|
Organic gas |
VOC |
50-5000ppm |
£ ±3%F |
2312-ADE23TH |
-20℃-200℃; 0-100%RH |
Alcohols, toluene, xylene, carbon monoxide, |
|
Organic gas |
VOC |
5-100ppm |
£ ±30%F |
2312-ADE25 |
10℃-50℃; 10-100%RH |
Hydrogen sulfide, sulfide. |
|
Organic gas |
VOC |
1-30ppm |
£ ±10%F |
2312-ADS02 |
10℃-50℃; 10-100%RH; |
Toluene, benzene, xylene and other benzene derivatives (100%), alcohols, ammonia (20%), and various toxic gas alarms. Suitable for monitoring air quality in work environments. |
|
Organic gas |
VOC |
>1-100ppm |
£ ±30%F |
2312-ADS00A |
10℃-50℃; 10-100%RH |
Methane, carbon monoxide, butane, alcohol, hydrogen |
|
Organic gas |
eVOC |
0.1-100ppm |
£ ±30%F |
2610-EPO |
-20℃-50℃; 15-90%RH |
Acetaldehyde (40), acetylene (340), acrylonitrile (75), butadiene (170), carbon disulfide (140), carbon monoxide (100), thiocarbonyl (135), dimethyl sulfide (150), epichlorohydrin (50), methyl ethyl ketone (27), i-propanol (78), ethanol (180), ethylene (220), ethylene oxide (275), formaldehyde (330), methanol (415), methyl mercaptan (275), tetrahydrothiophene, thiophene (45), vinyl acetate (200), vinyl chloride (200), toluene (55),a-Pinene (88), ethyl acetate (39), ethylene oxide (275), |
|
Organic gas |
VOC |
0-100% LEL |
£ ±30%F |
IR4110-HC |
-20℃-50℃; 15-90%RH EExdI/IIC T4 Class 1, Division 1, Groups A, B, C, D |
Organic hydrocarbons, including alkanes, alkenes, alkynes, ketones, aldehydes, acids, esters, aromatic compounds, etc. Not responding to other inorganic gases of the same magnitude. |
|
CPT2000-VOC Gas Alarm Beidou Satellite Instrument
1-1. Alkane gas transmitter at room temperature and atmospheric pressure:
Application:Methane, butane, natural gas. Anti alcohol.
CPT2312-ADS11 Volatile organic solvent concentration transmitter,Usually equippedXM3.5-1 alarm
Technical parameters:
Range: 500-10000ppm;
Operating temperature: -10℃-40℃;
Sample humidity:17-65%RH;
Response speed T60:< 10s;
Non linearity:<±30% (through)XM3.5-1 Simple Linearization);
Main purpose: Over limit alarm
MTBF:>1 year;
1-2. Wall mounted alkane gas alarm:
Application:Methane, butane, natural gas. Anti alcohol.
W-CPT2312-ADS11Wall mounted alkane gas alarm
Technical parameters:
Range: 500-10000ppm;
Operating temperature: -10℃-40℃;
Sample humidity:17-65%RH;
Response speed T60:< 10s;
Non linearity:<±30% (through)XM3.5-1 Simple Linearization);
Main purpose: Over limit alarm
MTBF:>1 year;
Organic solvent evaporation alarm at room temperature and atmospheric pressure:
CPT2312-ADE22T Volatile organic solvent concentration transmitter,Usually equippedXM3.5-1 alarm
Technical parameters:
Range: 50-5000ppm;
Operating temperature: -10℃-50℃;
Sample humidity:10-95%RH;
Response speed T60:< 10s;
Non linearity:<±30% (through)XM3.5-1 Simple Linearization);
Main purpose: Over limit alarm
MTBF:>1 year;
Organic solvent volatilization alarm under high temperature and atmospheric pressure:
CPT2312-ADE23T-F140 Volatile organic solvent concentration transmitter is usually equipped withXM3.5-1 alarm
Technical parameters:
Range: 50-5000ppm;
Operating temperature: -10℃-200℃;
Sample humidity:10-95%RH;
Response speed T60:< 10s;
Non linearity:<±10% (through)XM3.5-1 Simple Linearization);
Main purpose: Over limit alarm
MTBF:>1 year;
Organic solvent volatilization concentration detection transmitter under high temperature and atmospheric pressure:
TBD5-CPT2312-ADE23T-F140 Volatile organic solvent concentration transmitter
Can be equipped with a remote transmission secondary watchXM3.5-1 alarm
Or directly output switch signals to drive switch quantity control;
Or output analog adjustment signals for closed-loop control;
Technical parameters:
Range: 50-5000ppm;
Operating temperature: -10℃-200℃;
Sample humidity:10-95%RH;
Response speed T60:< 10s;
Non linearity:<±10% (through)TBD5 linearization);
Main applications: concentration detection, over limit alarm, or control;
MTBF:>1 year;