Shanghai Precision Instrument Co., Ltd
Home>Products>CM-825 series desktop reflectance spectrophotometer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    021-65729118
  • Address
    No. 1195 Pingliang Road, Shanghai
Contact Now
CM-825 series desktop reflectance spectrophotometer
CM-825 series desktop reflectance spectrophotometer
Product details

CM-825Desktop spectrophotometer

1、 Instrument Description

Desktop spectrophotometerCM-825It has excellent inter station deviation, high precision, and reproducibility. Regarding the exchange of color data between upstream and downstream or inspection of incoming and outgoing goods, as well as the color matching of coatings and inks.

Motor driven mirror reflection inserts can easily measure changes in color data of mirror or diffuse reflections. adjustableUVThe control device can automatically emit ultraviolet light(UV)Adjust to natural through precise filtersD65In the sunlight sourceUVmagnitude Simultaneously configure two pre-set settingsUVAdjust the frequency band

The large screen display makes it easy for you to view or directly change the instrument settings,Use matching color quality control software or color matching software(ColorMatch)You can choose the option to change the instrument status from the instrument or software. It has the function of measuring transparent and semi transparent color samples, and the configured color sample fixture can be used to conveniently measure the transmittance of transparent color samples. Provide measurements on semi transparent color samplesturbidityThe function.

The design of a dual spectrum analyzer ensures the long-term stability and measurement accuracy of the instrument by simultaneously obtaining measurement color samples and reference data from the internal environment for calculation. Improve the reproducibility, stability, and inter stage variability of the instrument.

High concentration pulsed xenon lamps can accurately read readings of dark or high concentration colors, and use noise ratio signals to eliminate all effects on surrounding light. No heat is generated and no preheating is required.

2、 Technical parameters
Repetition accuracy:0.015
Maximum value:0.03

Inter station difference:ΔE*ab 0.2Within(BCRASeries II 12Average value of block color board measurement

Light source: pulsed xenon lamp
Spectral range:360 nanometre– 740nanometre

Wavelength interval:10nm

Bandpass filter:10nm

Range of photometric measurement:0% - 200%reflectivity
Resolution of photometric measurement:0.001%
Reflection measurement aperture: large aperture(LAV)2.54 Centimeters(1 Inches)
Medium aperture(MAV)1.5 Centimeters(0.6 Inches)
Small Aperture(SAV)0.75cmx 1.0Centimeters(0.3inchx 0.4Inches)
Ultra small aperture(VSAV)0.3cmx 0.8Centimeters(0.12inchx 0.31Inches)

Color space:CIE Lab, LCh, CIE_Luv,XYZ,Yxy,reflectivity, Hunterlab, Munsell MI,CMYK,ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00Eab(Hunter)555Color tone classification, WI(ASTM E313-00,ASTM E313-73CIE/ISO,AATCC,Hunter,Taube,Berger Stensby)YI(ASTM D1925ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),metamerism indexMilmColor fastness, color fastness,ISOBrightness,8Glossiness,ADensity,Tdensity, EDensity,Mdensity

Color difference formula:ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),

ΔE*94,ΔE*00,ΔEab(Hunter),555,Color tone classification

Measurement time:< 1second
Transmission: full transmission and direct transmission
Optical configuration: Scattering/8°(Light source)/Measurement),15.2Centimeters(6Inch) integrating sphere,2A spectral analyzer
Temperature (operation):15˚ C - 32˚ C (60˚ F – 90˚ F)
Relative humidity (operation):0~45Relative humidity80%Or lower (in35°CBelow, there is no condensation of water vapor

Power Supply:117 VAC / 50 - 60 Hz230 VAC / 50 - 60 Hz
Interface:USB

External dimensions:583*330*304mm(Long)*wide*High)