CHA-S (A) reciprocating gas bath constant temperature oscillator
CHA-S (A) reciprocating gas bath constant temperature oscillator
Product details

1、 Product Introduction:

The gas bath constant temperature shaker (also known as the gas bath constant temperature shaker) is a biochemical instrument that combines a temperature controlled incubator and shaker. It is an indispensable laboratory equipment for precision cultivation and preparation in scientific research, education, and production departments such as plants, biology, microbiology, genetics, viruses, environmental protection, and medicine.CHA-S(A)Reciprocating gas bath constant temperature oscillatorIts main features are: 1. Accurate temperature control and digital display. 2. Open oxygen replenishment holes and ensure sufficient oxygen replenishment in the constant temperature working chamber. 3. Equipped with mechanical timing. 4. The universal spring bottle rack is particularly suitable for the cultivation and preparation of biological samples for various comparative experiments. 5. Stepless speed regulation, smooth operation, easy and safe operation.

IICHA-S(A)Reciprocating gas bath constant temperature oscillatorTechnical indicators:

① Speed range: starting~300r/min.
② Temperature control range: room temperature~50 ℃.
③ Temperature control accuracy: ± 1 ℃.
④ Amplitude: 20mm reciprocating (with A for speed measurement).
⑤ Heating power: 580W.
⑥ Working size: 440 × 360mm.
⑦ Timing range: 0-120min.
⑧ Current: AC 220V 50HZ.
⑨ Dimensions: 700 × 470 × 510mm

IIICHA-S(A)Reciprocating gas bath constant temperature oscillatorinstructions:

Using at medium speed within the speed range can extend the lifespan of the instrument.
2. The instrument should be placed on a sturdy workbench, and the environment should be kept clean, tidy, ventilated, and dry (to avoid interference from heat sources).
Before using the instrument, place the adjustment knob in the minimum position and turn off the "oscillation switch".
4. Attention should be paid to the following points when filling culture test bottles: In order to ensure good balance performance of the instrument during operation and avoid generating large vibrations, all bottle positions should be filled when bottling, and the culture medium in each bottle should be roughly equal. If there are not enough culture bottles, the test bottles can be symmetrically placed or filled with other equal amounts of solution to fill the empty spaces.
5. Connect the external power supply, place the power switch in the "on" position, and the indicator light will turn on.
6. Choose Constant Temperature: Choose Constant Temperature: Simply select the desired temperature on the thermostat according to the user manual, and the thermostat will automatically maintain a constant temperature.
When selecting the timer, adjust the timer knob to the "timer" or "normally open" position.
8. Turn on the oscillation switch, the indicator light will turn on, slowly adjust the speed control knob to the desired speed.
Before each shutdown, all switches should be placed in a non working state, the locator should be set to "zero", and the power should be cut off.

4、 Maintenance and upkeep:

1. Proper use and maintenance of the instrument can prolong its service life by keeping it in good working condition.
During continuous operation, the instrument should be checked every three months to ensure that no water droplets, dirt, or other debris have fallen onto the motor and control components; Check fuses, control components, and fastening screws
3. The bearings of the transmission part have been filled with an appropriate amount of lubricating grease (No. 1- calcium sodium based) before leaving the factory,CHA-S(A)Reciprocating gas bath constant temperature oscillatorDuring continuous operation, lubricating grease should be added every six months, with a filling amount of approximately one-third of the bearing space.
4. After long-term use, natural wear and tear is a normal phenomenon for the instrument. After one year of use, if abnormal noise is found in the motor, bearings are worn, belts are loose or cracked, heating and constant temperature are abnormal, electronic components fail, etc., our company will continue to provide high-quality service and assist in handling them.
5. Special specifications require a contract to be signed, and the price will be determined separately.