Product Introduction:
The CAAM-2001 series multifunctional atomic absorption spectrometer was jointly developed by multiple industry experts and renowned professors from Tsinghua University in China. It mainly uses flame atomic absorption analysis method, and also has multiple functions such as flow injection hydride atomic absorption method and graphite furnace atomic absorption method. It is currently a large precision analytical instrument with many functions and high cost-effectiveness among similar instruments at home and abroad. Professors Wu Tingzhao and Chen Lianyuan, who developed this instrument, are experts in the atomic absorption industry in China for many years and have experience in developing various types of instruments. They have combined their years of experience to improve the element testing sensitivity of the atomic absorption spectrometer to a new level. Their unique technology has made the sensitivity of flame atomic absorption reach an international excellent level, that is, 1 μ g/ml/Cu absorbance ≥ 0.3 (sensitivity<0.015 μ g/ml/1% A). Due to the multiple application methods of this spectrometer, a new laboratory can be established with one instrument, which is suitable for China's national conditions and very suitable for analysis and research work in various units.
1、 Detection methods and detectable trace elements of atomic absorption spectrometer:
1. Atomic absorption flame method:
Atomic absorption flame method (air acetylene) can detect elements up to PPM level.
Sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), chromium (Cr), manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), platinum (Pt), gold (Au), copper (Cu), silver (Ag), zinc (Zn), cadmium (Cd), lead (Pb), bismuth (Bi), etc.
2. Atomic absorption hydride method:
Atomic absorption hydride generation method can be used for trace detection of low melting point elements (PPb level). Measurement: Arsenic (As), Selenium (Se), Antimony (Sb), Bismuth (Bi), Lead (Pb), Tin (Sn), Tellurium (Te), Germanium (Ge), Mercury (Hg), etc.
3. Atomic absorption graphite furnace method:
The element detected by atomic absorption graphite furnace method has a small injection volume and high sensitivity (PPb level).
Silver (Ag), aluminum (Al), arsenic (As), gold (Au), barium (Ba), beryllium (Be), bismuth (Bi), calcium (Ca), cadmium (Cd), cerium (Ce), cobalt (Co), cesium (Cs), copper (Cu), dysprosium (Dy), erbium (Er), europium (Eu), iron (Fe), gallium (Ga), holmium (Ho), indium (In), potassium (K), lanthanum (La), lithium (Li), magnesium (Mg), manganese (Mn), molybdenum (Mo), sodium (Na), nickel (Ni), platinum (Pt), osmium Os, Pb, Pd, Pr, Hf, Rb, Ph, Ru, Sb, Sc, Se, Sm, Sn, Zr, Te, Ti, V, Zn, Si, etc.
2、 Application scope of atomic absorption spectrometer:
Atomic absorption spectroscopy is widely used for analysis and testing in various industries such as hospitals, pharmaceuticals, steel, health and epidemic prevention, metal smelting industry, geology and mineral resources, chemical industry, water quality monitoring, food and dairy products, environmental monitoring, quality inspection, drug testing, agriculture, toys, electronics, etc.
3、 The main features of CAAM-2001 series atomic absorption spectrometer are:
The CAAM-2001 series multifunctional atomic absorption spectrometer was proposed by Professor Wu Tingzhao (the developer of China's first atomic absorption spectrometer) and designed and developed by experts such as Professor Chen Lianyuan (the designer of Haiguang GGX-6 instrument, the only Zeeman background atomic absorption spectrometer in China). It is a large-scale precision analytical instrument with world advanced level.
1. High stability: The baseline stability of the instrument is ≤ 0.002A/30min, leading other atomic absorption spectrometer manufacturers at home and abroad. Baseline stability is a basic indicator for assessing an instrument, which determines a series of operating states of the host, such as noise, sensitivity, repeatability, etc.
2. High sensitivity: The atomic absorption spectrometer produced by Beijing Hanshi Manufacturing has achieved world leading sensitivity, far exceeding the technical indicators of the same industry in China. My instrument has a sensitivity (1 μ g/ml copper Cu absorbance ≥ 0.28Abs).
3. High energy: The instrument lamp current is controlled at 3mA-5mA (8mA-12mA from other manufacturers), the spectral bandwidth is 0.2nm, and the negative high voltage is between 150V-350V to achieve full transmittance. This way, your hollow cathode lamp can be used for more than half of the time, greatly saving consumables and procurement costs.
4. Unique USB interface: The domestic atomic absorption spectrometer is uniquely equipped with a USB interface, which is suitable for various types of computers and supporting office equipment, reflecting the instrument's foresight and compatibility.
5. Multiple leading patented technologies: Our company has multiple national patents in the manufacturing of atomic absorption spectrometers, such as high-performance hollow cathode lamps, glass high-efficiency atomizers, hydride generators, etc. The application of high-performance hollow cathode lamps has advantages such as high emission intensity, high measurement sensitivity, low detection limit, good stability, and disappearance of interference from adjacent spectral lines. The invention, production, and application of glass high-efficiency atomizers have greatly improved the sensitivity, detection limit, and stability of atomic absorption. The application of flow injection hydride generator in atomic absorption spectrometer has made the sensitivity and detection limit of hydride atomic absorption method reach the international level, with extremely high measurement efficiency, and can partially replace atomic fluorescence spectrophotometer. Our patented products account for over 90% of the original suction market share in the country.
6. Advanced technology, stability, and durability: The instrument won a gold medal at the BCEIA exhibition in 2003 (currently the latest atomic absorption BCEIA gold medal). Our company's instrument is the only atomic absorption instrument of its kind that dares to run the baseline at large-scale instrument exhibitions and trade shows in recent years. When exhibiting in various parts of Xinjiang, the road conditions are extremely bumpy, and the car can be immediately turned on for testing. For atomic absorption spectroscopy instruments, this stability is rare among similar instruments.
7. The world's only producer of pneumatic flow injection hydride generators: The atomic absorption spectrometer I produce, combined with my hydride generator, constitutes advanced pneumatic automation technology (only one click is needed to automatically complete the entire process of injection, generation, reading, and cleaning).
8. Humanized information processing software: The data processing software of our instrument, led by Deng Bo, a famous theoretical expert in the atomic absorption analysis field in China and a famous professor of Tsinghua University, combines the new achievements of data processing at home and abroad with the practice in the field of atomic absorption spectroscopy in China to give highly reliable data processing results. The designed software is convenient, fast and highly advanced. It is a masterpiece of atomic absorption software.
9. Integrated design of graphite furnace system and host: The graphite furnace system and flame atomizer automatically switch (E-type), making it very simple and fast to switch from the system to sample testing. Greatly saves analysis time. And an automatic sampler can be optionally selected.
4、 List of instrument users and industry customer testing elements:
Partial list of domestic users: Hubei Xiantao Yuanda Chemical Co., Ltd., Zhejiang Wenzhou Smelting General Factory, Zhejiang Zhuji Shanxiahu Pearl Group, Zhejiang Wenzhou 105 Military Industry Factory, Fujian Zijin Mining Group, Henan Luotong Group, Handan Iron and Steel, Jiangxi Geological and Mineral Bureau, Luoyang Steel Plant, Shandong Xintai City Center for Disease Control and Prevention, Hunan Leiyang City Center for Disease Control and Prevention, Shandong Zibo Refractory Material Factory, Fujian Institute of Oceanography, Xiamen University (purchased by Academician Huang Benli), Shanxi Gaoping Epidemic Prevention Station, Qiqihar Traditional Chinese Medicine Hospital, Heilongjiang Province Analysis and Testing Center, Anhui Hefei PLA 105 Hospital, Harbin Songhua River Pharmaceutical, Harbin Huarui Biochemical Pharmaceutical, Jilin Province Tonghua City Drug Control Institute, Guangdong Shiqiang Electronics, Chengdu Kaifei High Energy Chemical Industry Co., Ltd., Henan Wushe County Quality Inspection Institute, Guangdong Trace Element Research Institute Wuxi Henghong Precious Metal Electroplating Materials Co., Ltd., Wuxi Precious Metal Electronic Materials Co., Ltd., Yunnan Jianchuan Hongjun Zinc Industry Co., Ltd., Yunnan Gejiu Baisha Chong Quality Inspection Department, Yunnan Gejiu Nonferrous Metallurgy Co., Ltd., Nanjing Yilianda Electronics Co., Ltd., Shanghai Cooper Electric, Shanghai Jinguan Chemical Co., Ltd., Guangdong Shunde Midea Group, Guangdong Shenzhen Foxconn Group, Shenzhen Nanbo Group, Hubei Xiongtao Power Technology Co., Ltd., Hubei Daye Kaiyu Metallurgy Co., Ltd., Guangdong Zhongshan Yonghui Chemical, Shunde Haoheng Hardware Factory, Shenzhen Xinzhoubang Chemical, Shenzhen Jinmanchang Electroplating Factory, Guangzhou Xinlitai Battery Materials Co., Ltd., Jiangmen Hardware Material Products Factory, etc.
1. Hospitals: Qiqihar Traditional Chinese Medicine Hospital, Anshan Traditional Chinese Medicine Hospital, Anshan Occupational Disease Prevention and Control Hospital, Hunchun Mining Bureau General Hospital, Hefei PLA 105 Hospital, Chaohu Second People's Hospital, etc. Mainly measure the content of copper, iron, calcium, magnesium, zinc, selenium, lead, arsenic, cadmium, sodium and other elements in blood, urine, hair, etc.
2. Pharmaceutical factories: such as Heilongjiang Songhua River Pharmaceutical Co., Ltd., Harbin Huarui Biochemical Pharmaceutical Co., Ltd., Hulin Zhenbao Island Pharmaceutical Co., Ltd., etc. Mainly measure the content of lead, cadmium, arsenic, mercury, copper, calcium, magnesium, zinc and other substances in drugs.
3. Smelting industry: For example, user Huludao Hongjing Molybdenum Industry: detects the content of cobalt, manganese, vanadium, iron, calcium, magnesium, nickel, sodium, etc. in molybdenum iron. Henan Luotong Group: determination of copper, iron, zinc, manganese, lead, nickel, silver, bismuth, indium, antimony. Dalian Wafangdian Hengda Nonferrous Metal Foundry: Determine the content of aluminum, iron, manganese, lead, earth, antimony, silicon, nickel, tin, zinc, etc. in copper ingots.
4. Measure the content of lead, arsenic, mercury, copper, iron, calcium, magnesium, cadmium, etc. in food.
5. Measure the content of arsenic, cadmium, chromium, mercury, lead, antimony, selenium, barium, etc. in toys.
6. Measure the content of boron, iron, manganese, copper, zinc, lead, arsenic, mercury, etc. in the soil.
7. Measure the content of harmful elements such as lead, chromium, cadmium, mercury, barium, etc. in household appliances and electronic materials.
8. Measure the ion content of potassium, sodium, magnesium, aluminum, iron, zinc, copper, lead, manganese, etc. in ionic polymers.
9. Determine metal ions such as copper, zinc, lead, cadmium, hexavalent chromium, total chromium, calcium, magnesium, potassium, sodium, nickel, manganese, etc. in water.
5、 Technical parameters
1. Working conditions
1.1 Power Requirements: 220V (+5%~-10%), 50/60 Hz; 5000VA。
1.2 Environmental temperature:+15 ℃ to+35 ℃.
1.3 Relative humidity: 20-80%.
2. Technical indicators
2.1 Spectral system
2.1.1 Grating lines: 1800 lines/mm.
2.1.2 Wavelength range: 190-900nm.
2.1.3 Spectral bandwidth: automatically adjustable in five levels: 0, 0.2, 0.4, 1.0, and 2.0nm.
2.1.4 Wavelength accuracy: ≤ 0.15nm, wavelength repeatability: ± 0.05nm.
2.1.5 Baseline drift: Static ≤ 0.002A/30 minutes, dynamic ≤ 0.005A/30 minutes.
2.1.6 Light source: 3 light positions, manually switched.
2.1.7 High performance power supply: Built in high-performance lamp dual cathode power supply.
2.2 Graphite Furnace Atomizer
2.2.1 Characteristic quantity (Cd): 0.3 × 10-12g.
2.2.2 Detection limit (Cd): 0.2 × 10-12g.
2.2.3 Precision: RSD ≤ 2%.
2.2.4 Heating method: Vertical heating.
2.2.5 Safety protection: Water flow rate, water temperature, air pressure, poor contact of graphite tube, overcurrent and power alarm protection.
2.2.6 Heating and temperature control method: Room temperature around -3000 ℃, fully automatic temperature control up to 20 levels, furnace enrichment and concentration up to 20 times, 4 heating methods, longitudinal light control monitoring of graphite tube inner wall temperature.
2.3 Background correction: Graphite furnace: Deuterium lamp+self-priming background correction: capable of correcting 1A background.
2.4 Data Processing
2.4.1 Measurement methods: graphite furnace method, hydride method.
2.4.2 Concentration calculation method: Standard curve method (1-3 degree curve), automatic fitting, standard addition method.
2.4.3 Repeat measurement times: 1-99 times, calculate the average, provide the standard deviation and relative standard deviation.
2.4.4 Result printing: Parameter printing, data result printing, graphic printing, can export WORD and EXCEL documents.
2.4.5 Full Chinese interface, easy and convenient to operate, can achieve automatic conversion between flame atomizer and graphite furnace atomizer through software operation.
2.4.6 Communication Interface: The computer communicates with the host via USB interface.