TES-593 Broadband Electromagnetic Wave Pollution Intensity Detector
|
TES-593 broadband electromagnetic wave pollution intensityTester
|
|
|
- Test the frequency range of 10MHz to 8GHz
- Isometric electromagnetic field measurement
- Non directional measurement using 3-axis sensing rod
- High dynamic range using 3-channel digital processing
- Planned alarm limit value and storage function
- Easy to use * *
|
|
- Measurement of High Frequency (RF) Electromagnetic Wave Intensity
- Measurement of electromagnetic wave radiation intensity of mobile phone base station antenna
- Wireless communication applications (CW, TDMA, GSM, DECT)
- RF high-frequency electromagnetic wave usage**
- RF high-frequency transmitter power measurement
|
- Wireless network (Wi Fi) detection and installation
- Detection of Wireless Pinhole Camera
- Measurement of Electromagnetic Wave Radiation Intensity of Home Wireless Telephone
- Microwave oven radiation leakage detection
- Electromagnetic wave protection assessment for company or home environment
|
|
|
|
Electrical specifications
|
|
Sensor type
|
Electric field (E) |
|
Frequency range
|
10MHz to 8GHz |
|
Directional characteristic
|
Isomerism, 3-axis |
|
Measurement range (continuous wave signal>50MHz)
|
20mV/m to 108.0V/m 53μA/m to 286.4mA/m 1μW/m² to 30.93W/m² 0μW/cm² to 3.093mW/cm² |
|
Excellent error (@ 1V/m and 50MHz)
|
± 1.0dB |
|
Frequency response (including correction factor CAL)
|
± 1.0dB (50MHz to 1.9 GHz) ± 2.4dB(1.9GHz to 35GHz) |
|
Isotropic deviation
|
About ± 1.0dB at f>50 MHz |
|
Continuous wave overload limit (CW)
|
0.42mW/m² (40V/m) |
|
Temperature effect (0 to 50 ℃)
|
± 0.5dB |
|
|
Measurement method
|
Digital three-axis measurement |
|
Directional characteristic
|
Isomerism, Triaxial |
|
Selection of measurement range
|
One continuous gear |
|
display resolution
|
0.1mV/m, 0.1 μA/m, 0.1μW/m², 0.001μW/m² |
|
reaction time
|
About one second (measured from 0 to 90%) |
|
Display speed
|
About 0.5 seconds
|
|
monitor
|
LCD 4-digit number |
|
alarm
|
buzzer |
|
Measurement unit
|
mV/m , V/m , μA/m , mA/m , μW/m², mW/m², μW/cm²
|
|
Measurement display value
|
Real time measurement values, * large measurement values Average measurement value or * large average value |
|
Measurement alarm function
|
Adjustable limit value and can be turned on or off |
|
Measurement correction factor (CAL)
|
ADJUSTABLE |
|
Manual data storage and retrieval
|
99 sets (can only be read from the table) |
|
Dry battery
|
9V |
|
BATTERY LIFE
|
>15 hours |
| size |
Approximately 67 (width) x 60 (height) x 247 (length) |
| weight |
Approximately 260 grams (including battery) |
|
attachment
|
Instruction manual, battery, carrying case |
|
|
Related products:YS-2499A series dual channel pulse waveform displayPeak microwave power meter (dual channel pulse high-power meter);GX2BBSeries microwave power meter (RF power meter);YS1125 (B) microwave signal source (RF signal generator); YS3892 frequency selective amplifier; PXSeries microwave frequency meter (RF frequency meter);3cm(10cm)Waveguide testing system;FYS3000Complete set of waveguide testing system accessories;TC26Three centimeter waveguide measurement line;RCQ1AMicrowave leakage energy tester;SHK-4(3)Variable RF attenuator;BSeries fixed RF attenuator;YTJ8-3,YTJ8-4,YTJ8-5 seriesSMAJoint coaxial crystal RF detector; TJ8-4, TJ8-3, TJ8-5, TJ8-2 series coaxial crystal RF detectors, with optional British (N-type) or metric (L16) connector types); TTK-2/4Series RF coaxial switch;FYD(TT)Series RF directional coupler;YS(DTZ)Series microwave load;FYS(BD)Series waveguide components, etc