Tianjin Youxin Technology Co., Ltd
Home>Products>Beta ® Electromagnetic diaphragm metering pump
Beta ® Electromagnetic diaphragm metering pump
Beta ® Electromagnetic diaphragm metering pump
Product details
Beta ® Electromagnetic metering pumps can meet all the requirements for regulation and control functions in modern water treatment and chemical metering. Compared to before, its characteristic is the function of reducing and increasing pulse stepping. This makes it easier to accept adjustments from external signal sensors. Simplify the adjustment and measurement according to practical requirements. Due to the application of new technologies, energy consumption can be reduced by approximately 50%. The Beta metering pump can be easily readjusted during operation.
Advantages:
Pulse control step increases and decreases, achieving better results for existing signal sensors
Excellent adaptation effect

Match the corresponding hydraulic end for each chemical medium
Widely applicable
The drive has almost no wear and tear
Excellent stable operational performance
compare
Excellent cost-effectiveness
high efficiency
Energy saving rate of 50%Adjustable, integrated pulse step increase and decrease
Optional: Relay module, quick modification
feature
Measurement range: 0.74-32 l/h, 25-2 bar
Continuous adjustment of stroke length within the range of 0-100% (more...)
Optimal adjustment range: 30-100%)
Pump head materials: polypropylene, organic glass, polyvinylidene fluoride, polytetrafluoroethylene, and stainless steel
Polypropylene and organic glass pump heads with self exhaust function
HV pump head metering high viscosity medium
Power supply: 100-230V
Power: BT4b type is 7.2W-15.2W, BT5b type is 19.2W
The stroke frequency is adjusted from 10-100% in 10% steps
Passive external control contact pulse control
Two level liquid level switch connection
3 sets of LED display for operation, warning, and malfunction
Medium viscosity: ≤ 200 mPa. s (standard pump head); ≤ 500 mPa. s (with valve spring); ≤ 50 mPa. s (self exhaust)
Protection level: IP65
Insulation level: F
Application area: Measurement of chemicals and agents
Drinking water and swimming pool water treatment
chemical industry
process
Cooling water circulation
performance parameters
Beta model
pressure
traffic
Stroke flow rate Stroke frequency connection size suction lift bar l/h
ml/stroke 10 0.74 0.07 180 strokes/min. mm
mWC 16 1.10 0.10 180 BT4b1000*** 6×4
6.0** 16 2.20 0.20 180 BT4b1601*** 6×4
6.0** 16 3.60 0.35 180 BT4b1602*** 6×4
6.0** 7 7.10 0.66 180 BT4b1604*** 6×4
6.0** 4 12.30 1.14 180 BT4b0708*** 8×5
6.0** 2 19.00 1.76 180 BT4b0413 8×5
3.0** 25 2.90 0.27 180 BT4b0220 12×9
2.0** 10 6.80 0.63 180 BT5b2504 8×4***
6.0** 7 11.00 1.02 180 BT5b1008 8×5
6.0** 4 17.10 1.58 180 BT5b0713 8×5
4.0** 2 32.00 2.96 180 BT5b0420 12×9
3.0**
BT5b0232 16 0.59 0.06 180 12×9 2.0**
Beta series metering pump with automatic exhaust system 16 1.40 0.13 180 BT4b1601 6×4
1.8** 16 2.70 0.25 180 BT4b1602 6×4
2.1** 7 6.60 0.61 180 BT4b1604 6×4
2.7** 4 10.80 1.00 180 BT4b0708 8×5
2.0** 2 16.20 1.50 180 BT4b0413 8×5
2.0** 10 6.30 0.58 180 BT4b0220 12×9
2.0** 7 10.50 0.97 180 BT5b1008 8×5
3.0** 4 15.60 1.44 180 BT5b0713 8×5
2.5**
* BT5b042012×92.5**
** Beta ® When measuring high viscosity media, the measuring capacity of the metering pump will decrease by 10-20% and it will not be able to automatically introduce liquid. The G3/4-DN connector comes with a d16-DN10 nozzle assembly.
*** The values in the performance parameter table are the achievable values of the metering pump at room temperature with water as the medium. The interface size at the pump head exhaust valve is
**** 6×4
mm。
Suction stroke refers to the suction capacity parameter when the pump head and suction pipeline are empty, or when the suction pipeline contains air when the self discharge pump head is in use. The reduced models in 4 bar, 7 bar, and 10 bar can be applied in some special fields. For example, used in swimming pool systems. Detailed data can be provided upon request. When the inner diameter is 6mm, it is applied to stainless steel types. Material of overcurrent components
pump head Suction and discharge valve body sealing element Valve ball PPE
polypropylene polypropylene Ethylene Propylene Rubber ceramics PPB
polypropylene polypropylene fluororubber ceramics NPE
organic glass polyvinyl chloride Ethylene Propylene Rubber ceramics NPB
organic glass polyvinyl chloride fluororubber ceramics PVT
Polyvinylidene fluoride Polyvinylidene fluoride Polytetrafluoroethylene ceramics TTT
Graphite polytetrafluoroethylene Graphite polytetrafluoroethylene Polytetrafluoroethylene ceramics SST
Stainless steel 1.4404 Stainless steel 1.4404 Polytetrafluoroethylene ceramics PPT
polypropylene Polyvinylidene fluoride Polytetrafluoroethylene ceramics NPT
organic glass
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!