BSXZ-W type non partial discharge variable frequency series resonance
BSXZ-W type non partial discharge variable frequency series resonance
Product details
BSXZ-W型无局放变频串联谐振
BSXZ-W type non partial discharge variable frequency series resonance
Product Introduction
The BSXZ-W type non partial discharge variable frequency series resonance is mainly used to test the insulation level of various insulation materials, insulation structures, and electrical products that can withstand power frequency voltage. It is also used as a non partial discharge power supply for power frequency tests of transformers, transformers, lightning arresters, and other test samples. Widely used in electrical manufacturing departments, power operation departments, research institutions, and higher education institutions. Applicable objects: High voltage electrical equipment, such as transformers GIS、 Partial discharge and AC withstand voltage tests for transformers, switches, bushings, lightning arresters, cables, and power frequency AC withstand voltage tests for insulation materials.
Product Features
1. The complete set of equipment has a small local discharge capacity, which can ensure that the system's local discharge capacity is within the range of 5pC (special requirements can be customized).
2. The outer shell is made of epoxy resin casting and wrapped with glass fiber for non corona high-voltage insulation.
3. The complete set of equipment has low impedance, complete functions such as overvoltage and overcurrent flashover protection, and high reliability.
4. The pressure equalization cover is processed using a dedicated mold and formed from aluminum plate, with a smooth surface, light weight, and easy installation.
5. The large capacity high-voltage test device can achieve higher levels of intelligence and automation in system control, protection, and operation by selecting a power frequency intelligent measurement and control system.
6. Use fiber optic communication and sampling to thoroughly isolate high and low voltage control circuits.
7. The experimental process can perform real-time status self inspection and display
8. Equipped with comprehensive data and report management functions
9. High voltage U/T and I/T test curves can be recorded and plotted.
Technical parameters (special parameters can be customized)
Rated input voltage: three-phase 380V ± 10%, 50Hz.
Partial discharge level of complete equipment: ≤ 5pC under rated voltage (special customization for 2pC or below)
Output voltage stability: ≤ 1%
Voltage indication error: ≤ 1%
Noise: ≤ 65dB
Operating time (working system): Continuous operation for 60 minutes at rated voltage and rated current (can be customized for special requirements).
Overvoltage capability: At 1.1 times the rated voltage for 60 seconds, there will be no flashover, insulation breakdown, or any insulation damage.
Technical parameters of BSXZ-W type non partial discharge variable frequency series resonant withstand voltage device control console
model: BSXZ-W-50
Supply voltage and frequency: three-phase 380V ± 15%, 50Hz (partial discharge interference level of the power supply is less than 20pC).
Power supply capacity: greater than 60kVA
Rated output power: 50kW (maximum active power output)
Rated output voltage: 0-350V, continuously adjustable.
Rated output current: 143A
Output phase number: single-phase
Output waveform: pure sine wave
Output waveform distortion rate: ≤ 1.0%
Output voltage instability: ≤ 1.0%
Cooling method: forced air cooling
Adjustable frequency range: 20Hz~300Hz
Output frequency resolution: 0.1Hz
Output frequency instability: ≤ 0.5%
Noise level: ≤ 80dB
Partial discharge capacity:< 5pC
Allowable operating time: The allowable operating time under rated capacity is ≥ 1 hour.
Allowable temperature rise: Under rated load, continuous operation for 180 minutes, air outlet temperature rise ≤ 45K.
Technical parameters of excitation transformer for BSXZ-W type non partial discharge variable frequency series resonant withstand voltage device
model: BSJLB-W-100
Rated capacity: 50kVA
Number of phases: single-phase
Low voltage winding phase voltage: 2 × 350V, 2 × 400V, 2 × 450V.
Low voltage rated current: 143A
Rated voltage of high voltage winding: 2 × 10kV, 2 × 6.3kV. The high voltage winding consists of two independent windings. When parallel connected, the low voltage side is subjected to a 6.3kV transformer partial discharge test, and when series connected, the low voltage side is subjected to a 10kV transformer partial discharge test.
Insulation level: Induced voltage 1.2 times for 1 minute
Rated frequency: 50-300Hz
Partial discharge capacity: Local discharge capacity ≤ 10pC at rated voltage
Impedance voltage: ≤ 5%
Noise level: ≤ 65dB
Rated temperature rise: winding temperature rise less than 65K
Allowable continuous operation time: 60 minutes of continuous operation at rated voltage and rated current.
BSXZ-W type non partial discharge variable frequency series resonant withstand voltage device reactor
model: BSDK-W-90/15
Rated voltage: 15kV
Rated current: 6A/60min
Inductance value: 4H
Rated capacity: 90kVA
Usage frequency: 100-300Hz
Non linearity of inductance value: ≤ 1%
Insulation level: The reactor should be able to withstand a working voltage of 1.2 times its rated voltage for 1 minute without flashover or breakdown.
Partial discharge capacity at rated voltage: < 10pC
Allowable continuous operation time: 60 minutes of continuous operation at rated voltage and rated current.
BSXZ-W type non partial discharge variable frequency series resonant withstand voltage device voltage divider
model: BSFY-W-500/60
Rated voltage: 60kV
Capacity: C1=500pF
Working frequency: 30-300Hz
System measurement error: ≤ 2%
Insulation level: 66kV/1min
Dielectric loss: ≤ 0.2%
Structure: C1 is an epoxy shell oil paper insulated capacitor, and C2 uses materials with the same temperature coefficient, frequency coefficient, and C1.
Partial discharge capacity: ≤ 10pC
BSXZ-W型无局放变频串联谐振设备成套性
Note: Due to continuous product updates, the appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice, and our company reserves the right of interpretation; If there is any act of theft or copying, legal responsibility will be pursued.

Ordinary equipment supporting products
◆ Operating System
XC series high-voltage test transformer operation box: capacity: 2KVA-10KVA, input voltage: 0.22KV.
TC series high-voltage test transformer operation console: Capacity: 10KVA-50KVA, Input voltage: 0.22KV/0.38KV.
ZDTC series high-voltage test transformer electric operation console: Capacity: 50KVA-500KVA, Input voltage: 0.38KV.
FRC series resistive capacitive AC/DC voltage divider: FRC-50、100、150、200KV。
FZ series high-voltage DC discharge rod: FZ-70、140、210、280KV。
2DL series high-voltage silicon stack: 2DL-150, 300, 450, 600KV.
◆ Insulation bracket: 50, 100, 200, 300KV.
High voltage filtering capacitor: 0.01 μ F-0.1 μ F, 40KV-140KV, 40KV-210KV.
◆ Q series protective ball gap: Q-50、100、150、200、250、500。
Standard oil test cup: 400ml
Folding small cart: 150, 300 types.
Water resistance: 50KV, 100KV, 150KV.
YDQ-II series high-voltage voltage tester: 10KV, 35KV.
FRD series high-voltage nuclear phase transformer (phase transformer): 10KV, 35KV, 110KV, 220KV.
◆ Uniform pressure ball
H9840 type protective DC digital microampere meter
Various multimeters, megohmmeters, and test wires.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!