English

Shanghai Huanao Technology Co., Ltd
Home>Products>BINDER MK56 High and Low Temperature Alternating Climate Chamber
BINDER MK56 High and Low Temperature Alternating Climate Chamber
BINDER MK56 High and Low Temperature Alternating Climate Chamber
Product details

BINDER MK56 High and Low Temperature Alternating Climate Chamber

1、 Product Introduction:

1. Temperature range: -40 ℃ to 180 ℃

2、APT.lineTMPreheating chamber technology

3. Programmable condensation protection for samples

4. Observation window with internal lighting

5. BINDER communication software APT-COM ™ 3 Basic versions

6. Fault diagnosis system using optical and sound alarms

7. Intuitive touch screen controller using interval programming and real-time programming

8. Internal data logger and open format measurement values can be read through USB

9. Equipment self-test is used for comprehensive status analysis

10. Access hole with silicone plug 50mm, left

11. 4 casters, 2 with brakes

12. Computer interface: Ethernet

13. Adjustable slope function function function

14. Integrated continuous automatic recorder

15. Real time clock

16. 1 socket made of stainless steel

17. Internal chamber made of stainless steel

18. PT100 temperature sensor

19. Insulated with polyurethane foam

20. Fluorine free refrigerant R-404A

21. Cooling through a compression cooler

22. Finned evaporator

2、 Technical parameters:

Product Model MK056-230V1 MK056-230V1
Choose a model standard standard
Item code 9020-0316 9020-0395
measurement
Internal volume [L] 60 60
Net weight of equipment (unloaded) [kg] 165 165
Maximum total load [kg] 60 60
Maximum load per partition [kg] 15 15
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 720 720
Net weight at height [mm] 1445 1445
Depth net weight [mm] 780 780
Wall distance from rear [mm] 300 300
Wall to side distance [mm] 200 200
Observation window width [mm] 288 288
Observation window height [mm] 255 255
internal dimensions
Width [mm] 400 400
Height [mm] 420 420
Depth [mm] 348 348
number of doors
inner door 1 1
outer gate 1 1
Data related to the environment
Sound pressure level [dB (A)] 59 59
firmware
Number of partitions (hours/maximum) 1/4 1/4
Temperature performance data
Temperature range [℃] -40…180 -40…180
The temperature deviation depends on the set value [± K] 0.5…1.5 0.5…1.5
The temperature fluctuation depends on the set value [± K] 0.1…0.5 0.1…0.5
The average heating rate is based on IEC 60068-3-5 [K/min] 5.5 5.5
Cooling time from 180 ℃ to -40 ℃ [min] 90 90
The average cooling rate is based on IEC 60068-3-5 [K/min] 5.5 5.5
The maximum thermal compensation is at 25 ℃ [W] 800 800
Electrical data
Rated voltage [V] 200…230 200…240
Power frequency [Hz] 50 60
Rated power [kW] 2.8 2.8
Equipment safety device [A] 16 16
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!