BF-108B COD analyzer
Detection principle:
Using a sealed digestion tube, a special oxidant containing a certain amount of potassium dichromate is used to dissolve the water sample in a strong acidic solution at a constant temperature of 165 ℃ under the action of a catalyst, so that the reducing substances in the water are oxidized. The total absorbance of the unreduced Cr6+and reduced Cr3+in the water is measured at different wavelengths, or the absorbance of the reduced Cr3+is measured. After system processing, the C content (mg/L) is directly displayed.
Scope of application:
It can be widely used in colleges and universities, research institutes, sewage treatment plants, environmental monitoring stations, electroplating, petrochemicals, papermaking, pharmaceuticals, printing and dyeing, textiles, leather, brewing, dairy industry, electronics, municipal engineering and other industries.
Instrument appearance:
Instrument actual shooting image
Technical Specifications:
|
Measurement project |
Chemical Oxygen Demand |
Measurement range |
0-10000mg/L |
accuracy |
±5% |
detection limit |
5mg/L |
Optical stability |
≤ 0.001A/20 minutes |
Measurement time |
4 samples per batch in 20 minutes |
Temperature indication error |
±2℃ |
temperature uniformity |
±1℃ |
light source lifetime |
100,000 hours |
Number of curves |
Standard 3 with 57 extensions |
Store data |
2000 pieces |
display screen |
LCD display |
display interface |
All in Chinese |
Colorimetric method |
Colorimetric tube |
printer |
Thermal printer (optional) |
data interface |
USB |
ambient temperature |
5-40℃ |
ambient humidity |
Relative humidity ≤ 85% |
rated voltage |
3.7v 1A |
rated power |
<10w>10w> |
power capacity |
3000mA (charging) |
Appearance quality |
190*150*95(mm) 1.4kg |
Product Features:
1. Using the EPA approved method in the United States, in accordance with HJ/T399-2007, the measurement is accurate and effective.
2. Adopting imported high brightness and long-life cold light source, with excellent optical performance and a light source lifespan of up to 100000 hours.
3. Large LCD screen with full Chinese display, direct data reading, simple and time-saving operation.
4. Customized imported material colorimetric tubes for accurate, simple, and fast measurement, with no safety hazards.
5. It can save 60 standard curves and 2000 measured values (date, time, parameters, test data).
6. Memory standard working curve and expansion curve, users can calibrate the curve according to their needs.
7. One click factory reset, which can quickly recover in case of curve loss caused by misoperation.
8. It has data storage function and power-off protection function, making it convenient to query historical data and prevent data loss.
9. Equipped with a USB interface, data can be transferred to the computer for permanent storage.
10. Optional printing function, which can print the measured values immediately or query historical records for printing.
11. Choose a large capacity portable power bank to eliminate the inability to detect in the wild due to the lack of conventional power supply methods.
Standard configuration:
One set of portable host, one set of portable digestion analyzer, one set of colorimetric tube, one set of COD reagent, one colorimetric rack, and so on.